검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a new method of rapid preparation of carbon nanotube (CNT) solution with highly dispersed morphology by free arc excitation is proposed, which shortens the time of the preparation of CNT solution with low concentration. The principle is that the high-energy flow density heat generated by the free arc makes the vaporizable substance coated on the surface of CNTs vaporize rapidly, and then generates the bulk increasing motion, which makes the CNTs aggregates dispersed, and finally forms the CNTs gas-phase dispersion monomer with high dispersion or the cross-linking morphology of few CNTs. In this paper, the influence of gum Arabic (GA) and deionized water (DI water) contents in CNTs mixed electrode on the dispersion of CNTs in different environments (gas phase and liquid phase) is explored. In the limited case of this work, the dispersion effect is better when the mass ratio of CNTs, GA and DI water is 1:0.04:3.96 in the liquid-phase environment. The preparation method reported in this work is expected to be a rapid way to obtain low-concentration nanodispersion.
        4,000원
        2.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A liquid chromatographic method, using matrix solid-phase dispersion (MSPD) is developed for the extraction of residual furazolidone in chicken eggs. Blank or fortified egg samples (0.5 g) were blended with Octadecylsilyl (Bulk C,,, 40 pm, 18%. load, endcapped. 2 g) derivatized silica. After homogenization, C,,/egg and Na2S0, matrix were transferred to a column made of 10 ml glass synnge and filter paper and compressed 4.0-4.5 ml volume. The column was washed with 8 ml of hexane and dried under N, gas. Furazolidone was eluted with acetonitrile (8 ml) under gravity. The eluate containing furazolidone was free from interfering compounds when analyzed by HPLC with UV detection (365 nm, photodiode array). Calibration curves were linear (r = 0.99985) and inter- (1.47%) and intra-assay (5.29%) variabilities for the concentration range examined (7.8-497 ngig of eggs, 20 pl injection volume) were indicative of an acceptable methodology for the analysis of furazolidone. Average recovery of furazolidone added to egg was 96.2%. The limit of detection for the proposed method was 1 ng/g for furazolidone. The method using MSPD is proposed as an alternative assay to the classical method which involves the use of large volumes of a harmful solvent and requires a long tedious separation and clean-up processes prior to its determination.
        4,000원