This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.
방화구획 내 벽체에는 콘크리트, 조립식 패널, 건식벽체 등을 사용한 내화구조가 주로 적용되고 있으나 근래에 들어 시야 확보 및 미적 관점에 대한 관심이 증가하여 유리로 구성된 벽체의 수요가 발생하고 있다. 본 연구에서는 차열 유리를 적용한 스틸 내화벽체에 관한 것으로써 내부 방화구획에 적용 가능한 60분 내화벽체와 외부 벽체 및 커튼월에 적용 가능한 90분 내화벽체에 대하여 내화시험 및 성능분석을 수행 하였다. 시험 결과, 각 시험체의 요구 내화성능을 충족하는 것으로 나타났으며, 추가적으로 유한요소해석을 통한 유리벽체의 내화성능을 평가 하였으며 그 결과 1차적으로 시험체의 내화성능을 예측하는 것이 가능한 것으로 판단되었다.