Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
The core aim of this dissertation is to empirically scrutinize a strength characteristic of beam-column frame subjected to the cyclic lateral load, a beam-column frame of un-reinforced masonry wall, and a shear wall frame. First and foremost, I embark upon making three prototypes vis-à-vis this research. By conducting this process, I touch on an analysis of cyclic behavior and a damage characteristic of the beam-column frame, the beam-column frame of un-reinforced masonry wall, and the shear wall frame. What is more, through the previous procedure, the next part delves into the exact stress transfer path and the destructive mechanism to examine how much and how strong the beam-column frame of un-reinforced Masonry Wall does have a resistance capacity against earthquake in all the architecture constructed by the above-mentioned frame, as well as school buildings. In addition to the three prototypes, two more experimental models, a beam-column frame and shear wall frame, are used to compare with the beam-column frame of un-reinforced masonry wall. Lastly, the dissertation will suggest some solutions to improve the resistance capacity against earthquake regarding all constructions built with non bearing wall following having examining precisely all the analysis with regard to not only behavior properties and the damage mechanism of the beam-column frame and the beam-column frame of un-reinforced Masonry Wall but also the resistance capacity against earthquake of non bearing wall and school buildings.
본 연구에서는 전단벽-모멘트골조 시스템으로서 전단벽이 주로 횡력을 부담하는 철근콘크리트 건물을 대상으로 다양한 설치형식과 마찰력의 총량 및 분포를 갖는 마찰형 감쇠기의 제진보강 효과를 수치해석을 통해 비교 분석하였다. 감쇠기의 설치형식으로서 전단벽에 인접한 대각가새형, 벽체가 없는 골조를 보강하는 대각가새형 및 벽체 단부를 보강하는 수직경계요소형을 고려하였다. 하중기준 강화로 설계용보다 크게 증가한 지진하중에 대해 건물의 재료비선형성을 고려한 비선형시간이력해석을 수행하여 에너지소산, 횡하중 및 부재손상도 측면에서 마찰형 감쇠기의 제진성능을 비교 분석하였다. 기준마찰력의 30% 수준의 총마찰력을 갖는 벽체보강 대각가새형 설치형식이 전반적으로 가장 우수한 제진성능을 보이며,이 경우에 마찰력 배분방식은 중요하지 않았다. 또한 일부층에 집중설치함으로써 전층설치에 약간 못미치는 제진성능을 얻을 수 있었다.
본 연구에서는 민감도 해석을 이용하여 전단벽-골조 구조시스템의 횡변위를 정량적으로 제어할 수 있는 강성최적설계방안을 제시하고자 한다. 이를 위해 먼저 골조와 전단벽요소 사이의 변위자유도 적합성 문제를 해결하기 위한 요소강성행렬을 구성하며, 또한 수학적계획법의 일반성을 유지하면서도 큰 규모의 문제도 효율적으로 다를 수 있는 근사화 재념을 도입하여 횡변위 구속조건식을 설정한다. 아울러 전단벽 및 골조부재의 단면특성 관계식을 설정함으로써 설계변수의 수를 줄여주고, 이를 이용하여 강성행렬도함수의 산정을 용이하게 한다. 특히 골조의 경우 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 최적설계결과에서 구해진 단면특성에 따라 부재단면크기를 산출하고, 전단벽은 사용자의 의도에 따라 두께 또는 부재길이를 재산정하는 방안을 강구한다. 이와 같이 제시된 강성최적설계기법의 효용성을 검토하기 위해 두 가지 형태의 20층 전단벽-골조 구조물의 예제가 고려된다.
횡력을 받는 전단벽-골조 시스템은 휨거동을 하는 전단벽과 전단거동을 하는 골조가 슬래브의 강체평면운동(Diaphragm Action)을 통하여 상호작용하여 수평력에 효율적으로 저항하는 시스템이다. 횡력을 받는 골조의 거동은 보와 기둥의 휨 변형에 의한 골조의 수평 전단변형과 기둥의 축 변형에 의한 골조의 휨 변형으로 구분 할 수 있다. 일반적으로 전단벽-골조 시스템의 근사해석 시 골조의 휨변형은 무시하여 왔으나, 건물의 높이가 증가 할수록 골조의 휨 거동은 큰 영향을 미칠 것으로 사료된다.
따라서 본 연구에서는 횡력을 받는 전단벽-골조 시스템의 근사해석 시 기둥의 축 변형을 고려하기위하여 병렬전단벽 시스템(Coupled Shear Wall System)의 해석 시 사용하는 연속매체모델(Continuous Medium Model)을 이용하여 횡 변위 및 부재력을 산정할 수 있는 근사식을 수정 제시 하였다. 새롭게 제시된 근사식을 검토하기 위하여 기존 식과 컴퓨터에 의한 Matrix해석 결과와 비교하였으며, 비교결과 건물 높이가 높을수록 본 연구에서 제시한 근사해석 식이 기존 식보다 Matrix 해석 결과에 가깝게 나타났다.
본 연구는 MIDAS-Gen을 사용하여 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하였다. 본 연구에서 는 해석 변수로 상부 전단벽의 미배치 층수, 상하 기둥 단면 치수의 변화, 상하 전단벽 두께 치수의 변화를 설정하였다. 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하기 위하여 전단벽의 미배치에 따른 전단력/전도모멘트 분포, 전단벽의 변곡점, 수평강성 에 대하여 비교분석하였다. 본 연구의 결과는 골조-전단벽 구조에서 상부 전단벽의 미배치가 수평강성과 같은 구조성능에 미치는 영향을 정량 적으로 제시하였다. 더욱이 본 연구의 결과는 합리적인 골조-전단벽 구조를 위한 구조설계 자료를 제공하는데 도움이 된다고 확인하였다.