The purpose of this study is to investigate the causes of corrosion of steel plate deck longitudinal U-ribs and to investigate the reinforcement method. It was confirmed that the corrosion of the longitudinal U-ribs occurred due to penetration water of the bolt hole of the shear key used in construction. The longitudinal U-ribs which were corroded were stiffened by attaching reinforcing plates, and finishing treatment was performed to prevent the surface water from flowing into the inside.
In this study, It was purpose to provide preliminary data for extension of the applicability of deep corrugated steel plate composite members by steel grade and shear reinforcement method. From the result of flexural test on deep corrugated plates composite members using GR40 and SS590, positive moment capacity was increased about 28% by SS590 steel. But to change steel grade was proved to have insignificant effects for increasement of negative moment capacity. In the moment test result of same overlapping length, Increasement rate of positive and negative moment capacity was not significantly improved by increasing the number of bolt. It was estimated to be due to the characteristics of bolt connection such as distance between centers of bolts, edge distance of bolt. In the test result on the spacing of shear reinforcement, positive moment capacity was increased and deformation of negative moment was reduced as the distance decrease. In the test result on the shape of shear reinforcement, positive and negative moment resistance was increased about 2% ~ 7% by U shaped shear reinforcement. In conclusion It was estimated that moment capacity of deep corrugated steel plate composite members are depend on steel grade of deep corrugated steel plate, spacing of shear reinforcement and reinforcing bar.
This paper presented to study used Abaqus on steel plate bonded reinforcement technology for column to beam connections, and then the result showed that steel plate bonded reinforcement technology has great reinforcement effect for RC column to beam joint. Also the steel plate bonded reinforcement technology was safety and convenient operation.