In this study, a prefabricated buckling brace (PF-BRB) was proposed, and a test specimen was manufactured based on the design formula for the initial shape and structural performance tests were performed. As a result of the experiment, all standard performance requirements presented by KDS 41 17 00 and MOE 2021 were satisfied before and after replacement of the reinforcement module, and no fracture of the joint module occurred. As a result of the incremental load test, the physical properties showed a significant difference in the stiffness ratio after yielding under the compressive load of the envelope according to the experimental results. It is judged necessary to further analyze the physical properties according to the experimental results through finite element analysis in the future.
프리캐스트 코핑의 중공부 주철근 단절로 인한 단점을 보완하고, 거치대 삽입 없이 주철근을 거치대로 활용할 수 있 도록 철근-콘크리트 접촉부의 응력집중을 완화할 수 있는 하중분산세트의 성능을 검토하였다. 유한요소해석 및 축소모형실험을 통해 검토한 결과 하중분산세트는 철근-콘크리트 접촉부의 응력집중을 효과적으로 완화시켜 거치 시 콘크리트 파손을 방지할 수 있을 것으로 판단된다.
Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.
본 연구에서는 구조물의 모니터링 시스템을 위하여 최근에 급속하게 발전하는 스마트 센서 기술을 이용하여 스마트 센서 장치를 개발하였고 다양한 실험을 통하여 개발한 스마트 센서의 기본적 성능 평가와 모형 구조물을 이용한 손상 검출 실험을 실시하였다. 본 논문은 Part 1로써 스마트 센서의 개발과 성능 평가에 관한 것이고 Part 2에서는 스마트 센서를 이용한 손상 검출 결과를 유선 계측 시스템을 이용한 실험결과와 비교하였다. 스마트 센서는 고 출력의 무선 모뎀과 고 성능 MEMS 센서, AVR 마이크로컨트롤러를 이용하여 개발하였으며 센서의 제어와 운영을 위한 임베디드 프로그램을 개발하였다. 스마트 센서의 성능을 검증하기 위하여 민감도와 분해능 분석 실험과 캔틸레버 보와 가진기를 이용한 데이터 획득 실험, 실 구조물을 이용한 현장 적용 실험을 실시하였다. 실험 결과, 개발한 스마트 센서의 성능에 대한 만족스런 결과를 얻었다.