검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to explore the appropriate water pressure control of water supply pipeline to reduce water losses of water supply network in Jinan-gun. The current water pressure status of each 5 blocks and the impact of optimized water pressure on improving revenue water rate were investigated. In order to obtain the flow rate and water pressure data of each small block, a smart hub is set in the pressure reducing valve chamber at the inlet of the small block, and a smart water pressure meter is installed in the fire hydrant and the faucet of the customer. For the pressure reducing valves installed for water pressure management system of each block, the diameter calculation standard and type of the pressure reducing valve are determined, and the application reasons are put forward. The analysis results of water pressure management for each small block in Jinan-gun show that the pressure control equipment and water pressure management need to be improved in four small blocks. The water flow rate in Jinan-eup and Sangjeon-myeon increases from 57.2% to 87.6% when the water pressure control is completed.
        4,000원
        2.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 GFRP관을 상수도관으로 사용하기 위해 테스트베드를 설치하여 지중매설된 관의 구조적 거동에 미치는 영향을 조사하였다. 또한, GFRP관의 역학적 성질을 조사하고 관 강성을 추정하였다. KS규격에서 제시하고 있는 허용드로우와 고압력(사용압력의 1.5∼2.0배), 트럭하중을 적용시켜 관 내부와 외부의 복합하중이 작용할 경우 관 내압의 변화와 관의 거동을 확인하였다. 그 결과, 상수관으로 GFRP관을 장기 사용하여도 충분한 내압을 가지고 있음을 확인하였다.
        4,000원
        3.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to global climate change, mega-droughts have occurred frequently. Since long-term droughts make it difficult to secure the water resources, water supply needs to be restricted in a reasonable manner. In the event of limited water supply, the waterworks need to develop a restricted water supply strategy. This study showed that analyzing daily water supply could be used to respond to the first stage of a drought. According to an analysis of Korea's major water authorities, there was about 7~21% of room for daily minimum water supply in case of a drought. Restricting the water supply by lowering pressure is a good strategy for local water authorities with high water leakage rate since leakage is inversely dependent with pressure. For this method, it is necessary to quantify water deficiency and pressure at each node using a simulation. Since DDA-based software is not possible to predict changes in demand at nodes with pressure reduction, WaterGEMS, a PDA software, was used to quantitatively predict water shortages and pressures at each node. Locations where water is deficient need to install booster pumps or to be dispatched with water tank truck and bottled water. Without these support, lowering pressure could not be an option for water works. This paper suggests a method for waterworks to plan a drought by lowering pressure to restrict water supply using daily water supply analysis and PDA based simulation.
        4,000원
        4.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipes are widely used in the water supply pipeline system. However, they have some disadvantages such as reduced durability due to material degradation, defects in connections, breakage of pipelines, and difficulties in continuous maintenance. To mitigate such problems, recently, research on durable and outstanding corrosion resistant glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, it should review the structural behavior and interaction between buried pipe and its surrounding soil because pipe will support the load with the surrounding soil together at the same time. To apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        4,000원
        5.
        2016.04 구독 인증기관·개인회원 무료
        In the water supply pipeline system polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipe are mostly used. However, they have some problems such as reduced durability due to material degradation, defects in connections, the pipelines breakage, and lack of continuous maintenance. Recently, research on durable and outstanding corrosion resistance glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, pipe will support the load with the surrounding soil. In this paper, to apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.