Development of carbon-based biocompatible and flexible nanosensors is essential in different practical applications. Humidity sensor is crucial in different fields among them. Herein, a unique metal-free nanosensor comprised of 2D-graphitic carbon nitride (CN) decorated with 0D-carbon dots (C-dots) was fabricated to monitor humidity in human breath. Simple polymerization and carbonization techniques were used to synthesize nitrogen enriched heterostructure (CN@C-dots). The synthesized heterostructure showed excellent physicochemical properties including high surface area, hydrophilic functionalities and more active sites that were responsible for enhanced humidity sensing. The fabricated nanosensor indicated excellent resistivity against humidity due to diffused proton hoping through inhibition of ion transfer from multiple water layers. The interaction mechanism was explained through simple hydrogen bonding and defective site chemisorbed oxygen participation in physisorbed humidity molecules.
본 연구는 코마개의 사용 여부에 따라 MRI 영상을 분석함으로써 숨 참기의 정확도를 향상할 도구로써 코마개가 실 효성이 있는지 검증하고자 하였다. 이를 위해 수검자에게 코마개가 없는 자연 호흡과 코마개를 사용한 구강 호흡 상태에서 호기 후 숨 참기를 지시하고 MRI 영상을 획득하였다. 영상은 2D 경사 자기장 에코 시퀀스로 획득하였고 초당 1장씩, 총 15장을 얻어 숨 참기 상태를 분석하였다. 숨 참기의 상태를 정량적으로 평가하기 위해 우측 폐 면적 을 측정하였다. 그리고 첫 번째 영상의 폐 면적을 기준으로 나머지 영상들에서 폐 면적의 절대 오차값을 구해 비교하 였다. 더불어 첫 번째 영상을 기준으로 나머지 영상들의 기하학적 유사도를 평가하기 위해 SSIM 값을 계산하였다. 실험 결과, 자연 호흡 상태에서 절대 오차는 평균 216.79 ㎟로 나타났다. 반면, 코마개를 사용한 구강 호흡의 경우 평균 55.94 ㎟로 나타나 자연 호흡과 비교하여 약 74.19% 감소하였다. SSIM 값은 자연 호흡 시 평균 0.7, 구강 호흡 시 0.76으로 나타나 기하학적 유사도가 약 6% 향상되었다. 이는 코마개 사용 시 호흡의 초기 상태를 잘 유지함 으로써 숨 참기의 정확도가 향상되어 능동적으로 호흡 상태를 조절할 수 있는 도구로써 충분한 가치가 있음을 증명한 다. 따라서 복부 MRI 검사에서 호흡에 따른 인공물을 개선하는 데 코마개가 도움을 줄 수 있으며 영상 개선 및 업무 효율을 높이는 도구로써 충분히 활용할 수 있다.
The oral care probiotic strain Weissella cibaria CMU (oraCMU) inhibits volatile sulphur compounds associated with halitosis, presumably by inhibiting the growth of associated oral pathogens. In the present study, we investigated whether oraCMU inhibits the production of these compounds by suppressing the expression of mgl . This gene encodes L-methionine-α-deamino-γ-mercaptomethane-lyase (METase) and is involved in the production of methyl mercaptan (CH3SH) by Porphyromonas gingivalis . Therefore, we specifically investigated the effects of oraCMU on the growth, CH3SH production, METase activity, and mgl expression of P. gingivalis . The minimum inhibitory concentrations of cell-free supernatant and secreted proteins from oraCMU were 125 mg/mL and 800 µg/mL, respectively. At sub-minimum inhibitory concentration levels, these metabolites inhibited CH3SH production, but they also reduced P. gingivalis viability. Only heat-killed oraCMU decreased CH3SH production without affecting P. gingivalis viability. Heat-killed oraCMU also inhibited METase activity toward L-methionine and mgl mRNA expression (p < 0.05). In summary, we demonstrated the inhibition of volatile sulphur compounds via the antimicrobial action of oraCMU and, for the first time, the inhibition of such compounds by heat-killed oraCMU, which occurred at the molecular level.
목 적 : 기존 Single RF source에서는 환자의 해부학적 차이에 따른 영상신호의 불균형으로 인해 dielectric shading artifact가 발생하여 최근 이를 개선하고자 dual RF source를 사용하고 있다. 본 논문은 dual RF source 사용 시 필요한 B1 calibration scan의 호흡방법 변화에 따라 영상에 어떤 영향을 미치는지 알아보고자 한다.
대상 및 방법 : 복부질환이 없는 건강한 지원자 14명을 대상으로 검사장비는 Archieva 3.0T TX(philips medical system, Netherlands)를 사용하였고, 신호수집 코일은 32channel sense cardiac coil을 사용하였다. 검사방법은 호흡을 실제 검사와 동일한 expiration, 변형한 방법인 free breathing과 inspiration하는 방법으로 B1 calibraion scan을 각각 실시하여 호흡방법의 변화에 따라 B1 calibration scan 후 3D dual echo, e-THRIVE sequence/Axial 영상을 획득하였다. 평가방법은 정량적 방법으로 liver를 9개 구역으로 나누어 SNR과 CNR을 비교 측정하였고, 정성적 평가방법은 방사선사 3명이 영상의 homogeneity와 background noise 발생 정도를 3점 척도로 상대평가 하였다. 평가된 값은 Wilcoxon signed rank test(SPSS 18.0K for windows)로 통계처리 하였다.
결 과 : 정량적 평가는 expiration, Free breathing, inspiration 일 때 3D dual echo의 SNR은 251.05/167.07/183.53, e-THRIVE 161.08/117.22/128.38로 나타났고, CNR은 3D dual echo에서 73.68/56.4/55.69, e-THRIVE 62.61/40.34/35로 나타났다. 정성적 평가는 3D dual echo 2.30/1.76/1.94, e-THRIVE 2.56/1.46/1.98로 나타났다. 통계적 분석은 expiration 일 때 통계적으로 유의하였으나(p<0.05), free breathing과 inspiration 사이에서는 통계적으로 유의하지 않았다(p>0.05).
결 론 : 실제 검사와 동일한 호흡방법인 expiration으로 B1 calibration scan을 하였을 때 3D dual echo와 e-THRIVE에서 영상이 제일 우수한 것으로 나타났다. 다른 호흡방법으로 실시한 경우에는 SNR과 CNR이 저하되고 심할 경우 dielectric shading artifact가 발생하여 영상의 질을 감소시킴을 알 수 있었다. 따라서 복부 MRI 검사 시실제 검사방법과 동일한 호흡방법으로 얻은 B1 calibration scan이 보다 진단학적 가치가 높은 영상을 구현함을 확인 할 수 있었다.