        검색결과 9

        1.
        2023.11 구독 인증기관·개인회원 무료
        Heavy water primary system decontamination technology is essential to reduce worker exposure and improve safety during maintenance and decommissioning of nuclear facilities. Advanced decontamination technology development aims to secure controlled decontamination technologies that can reduce the cost of radiation exposure and dramatically reduce the amount of secondary waste generated when decontaminating large equipment and large-area facilities. We conducted a study to identify candidate corrosion inhibitors through the literature and analyze the degree of corrosion of carbon steel samples. Countries with advanced nuclear technology have developed chemical decontamination technology for the entire nuclear power generation system and applied it to the dismantling and maintenance of nuclear power plants. In the decontamination process, the corrosion oxide film must be removed. If the base metal is corroded by the decontaminant in this process, additional secondary waste is generated and treatment costs increase. Therefore, it is necessary to develop a corrosion inhibitor that inhibits the corrosion of the carbon steel base metal in the decontamination process to generate a secondary waste liquid that is favorable for waste reduction and treatment. In this presentation, a study was conducted to analyze the extent of corrosion on a carbon steel base material and identify candidate materials for corrosion inhibition testing. Samples were analyzed using optical microscopy and EPMA analysis to determine the thickness of the corroded oxide film. EPMA analysis also allowed us to map the elemental distribution of the carbon steel corrosion layer, which we plan to quantify in the future. The candidate materials for organic-based corrosion inhibitor were also selected based on their inhibition mechanism; having high electronegative elements for coordinate covalent bonding at metal surface and hydrophobic nonpolar group for preventing access of corrosive substances.The selection of candidate materials for corrosion inhibition testing was based on the mechanism of the corrosion inhibitor. Organic-based corrosion inhibitors are adsorbed by donor-acceptor interactions between metal surfaces and highly electronegative elements. Corrosion can also be inhibited by arranging hydrophobic nonpolar groups on metal surfaces in the solution direction to prevent access of corrosive substances.
        2.
        2012.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        순환전압전류법을 사용하여 전류-전압 곡선을 측정하였다. 전기화학적 특성과 금속의 표면상태간의 관계는 전자현미경(SEM)을 사용하여 조사하였다. 그리고 순환전압전류법에 의한 전기화학적 측정은 3 전극 시스템을 사용하였다. 측정 범위는 초기 포텐셜에서 -1350 mV까지 환원시키고, 연속적으로 1650 mV까지 산화시키고, 다시 초기지점으로 환원시켜 측정하였다. 스캔속도는 50, 100, 150, 200 및 250 mV/s를 선정하였다. 그 결과, 부식억제로 모노에탄올아민(MEA)을 사용하여 금속의 C-V 특성은 순환전압전류법으로부터 산화 전류에 기인한 비가역 공정으로 나타났다. 부식억제제로 MEA을 사용하였을 경우에는 전해질의 농도가 증가할수록 확산계수가 감소하는 경향을 나타내었다. 그리고 구리의 SEM 이미지를 보면, 전해질 농도를 증가시키면 표면부식은 증가하였다. 부식억제제로 1.0×10-3M MEA를 첨가시키면, 전해질 농도 0.1 N의 경우 확산계수가 상대적으로 커서 부식억제 효과가 적었다.
        4,000원
        3.
        2017.09 서비스 종료(열람 제한)
        In this study, Corrosion behavior in mortar was observed by the passage of time by using EIS method. As a result of EIS experiment, equivalent circuit and changes of Impedance parameter could be observed. In addition, it was confirmed that impedance of rebar in concrete and corrosion rate according to the amount of NaCl and LiNO2 were different.
        5.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        In this study, corrosion potential (Ecorr), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors’ relationship to Ecorr, corrosion rate, and polarization resistance was not shown.
        6.
        2013.04 서비스 종료(열람 제한)
        In this study, in order to comprehend performance of corrosion inhibitor, the experiment study was conducted about corrosion characteristic 3 steps(0.0, 0.6, 1.2) of Chloride by added amount of inorganic(Ca(NO2)2) and organic(DMEA) corrosion inhibitor by the corrosion inhibitor types about 0.6kg/m3, 2.4kg/m3 based on Chloride ion content 1.2kg/m3 for service life prediction of concrete structure by using Poteniostat. As a results, the excellent anti-corrosive performance of organic corrosion inhibitor was seen that absorption types organic corrosion inhibitor has excellent anti-corrosive performance compared to the inorganic nitrous acid corrosion inhibitor by the added amount of corrosion inhibitor
        7.
        2012.11 서비스 종료(열람 제한)
        In this study, in order to comprehend performance of corrosion inhibitor, the experiment study was conducted about corrosion characteristic of 3 steps(0.0, norm 1/2, norm) compared to organic corrosion inhibitor standard use of liquid and molar 3 steps(0.0, 0.3, 0.6%) of Chloride by added amount of inorganic corrosion inhibitor by the corrosion inhibitor types about 2.4kg/m3, 4.8kg/m3 based on Chloride ion content 1.2kg/m3 for service life prediction of concrete structure by using Poteniostat.
        8.
        2009.09 KCI 등재 서비스 종료(열람 제한)
        철근이 부식되면 오염된 콘크리트를 제거하고 철근방식을 하고 보수하는 방법과 방청제를 도포하는 방법으로는 철근위치에서 방청성능을 확보하기가 곤란한 실정이다. 이에 본 연구에서는 철근위치까지 방청제를 고압 침투시키기 위한 연구개발에 앞서 방청제 가압 침투 실험을 통하여 침투깊이를 측정하고 위치별 아질산이온의 양을 측정하여 물시멘트비, 압력, 가압시간에 따른 침투깊이 예측하고 우수한 방청성을 가지는 염화물이온과 아질산이온의 몰비 0.6 이상이 되는 물시멘트비와 압력, 가압시간을 산정하였다. 실험결과 물시멘트비가 방청제의 침투에 가장 큰 영향을 주며 또한 실험체의 깊이가 깊어질수록 침투시킨 방청제의 농도는 같지 않고 낮아지는 것을 알 수 있었다.
        9.
        2009.02 KCI 등재 서비스 종료(열람 제한)
        This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of 80℃. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.