In the ongoing project, the major building technology companies in Finland are joining forces to research and develop a platform based ecosystem in the intelligent building context. From the business perspective, one of the main question is which kind of business model is needed in the future ecosystem. Keywords: smart buildings; platform economy; ecosystem; business model innovations
In this study, a smart skin system that combines SPD (suspended particle display) and LGG (Lighting Guide Glass) and its optimal control method was developed for the purpose of simultaneously reducing the lighting load and cooling load in office buildings. And a demonstration site was built to test the results. The demonstration site was constructed as an experimental group with a smart skin system installed and a control group with a general window system installed. When the cooling energy consumption of the experimental group to which the smart skin system was applied was reduced by about 36.9% compared to the control group, the lighting energy was also reduced by 54.4%.
A smart connective control system was invented recently for coupling control of adjacent buildings. Previous studies on this topic focused on development of control algorithm for the smart connective control system and design method of control device. Usually, a smart control devices are applied to building structures after structural design. However, because structural characteristics of building structure with control devices changes, a iterative design is required for optimal design. To defeat this problem, an integrated optimal design method for a smart connective control system and connected buildings was proposed. For this purpose, an artificial seismic load was generated for control performance evaluation of the smart coupling control system. 20-story and 12-story adjacent buildings were used as example structures and an MR (magnetorheological) damper was used as a smart control device to connect adjacent two buildings. NSGA-II was used for multi-objective integrated optimization of structure-smart control device. Numerical simulation results show the integrated optimal design method proposed in this study can provide various optimal designs for smart connective control system and connected buildings presenting good control performance.
In this study, we have investigated the optimal control method and the energy saving possibility when the dimming control for lighting and the suspended particles display(SPD) glass for window were applied to reduce the lighting load and the cooling load in office buildings. Simulations were carried out during from 8:00 am to 7:00 pm of typical one day on summer, winter and intermediate season. Simulation results showed that the cooling and lighting energy usage was reduced to 21.2% compared to the baseline model. Therefore, it was possible to predict the optimum control method of the suspended particles display(SPD) window to control the transmittance for energy saving and the dimming control for lighting during summer season.
본 연구에서는 MR 감쇠기와 FPS를 사용하여 구성된 스마트 스카이브릿지를 제안하였으며 스마트 스카이브릿지로 연결된 인접건물의 지진응답 제어성능을 분석하였다. 이를 위하여 스마트 스카이브릿지로 연결된 10층과 20층 구조물을 예제 구조물로 선택하였고 근거리 (near fault) 및 원거리 (far fault) 지진의 특성을 가지는 El Centro 지진과 Kobe지진을 사용하여 시간이력해석을 수행하였다. 스마트 스카이브릿지블 효과적으로 제어하기 위해서 퍼지논리제어기를 개발하였으며 퍼지논리제어기를 최적화하기 위하여 다목적 유전자알고리즘을 사용하였다. 최적화결과 10층 건물의 지진응답과 20층 건물의 지진응답 사이에는 상충관계 (trade-off)가 있는 것을 알 수 있었고 다목적 유전자알고리즘을 통해서 두 건물의 지진응답 제어에 대한 퍼지논리제어거의 파레토 해집합을 구할 수 있었다. 수치해석결과 본 연구에서 제안한 스마트 스카이브릿지를 사용하면 연결된 건물의 지진응답을 효율적으로 저감시킬 수 있는 것을 알 수 있었다.
본 연구에서는 면진 건물의 내진 성능을 개선하기 위하여 최근 개발된 스마트 수동 제어 시스템을 적용하고 이의 효용성을 수치 모의실험을 통해 검증하였다. 스마트 수동 제어 시스템은 효과적인 반능동 제어 장치로 알려진 MR 감쇠기에 전자기 유도부를 도입하여 응답 변화에 따라 MR 감쇠기로 입력되는 전류를 변화시킴으로써 MR 감쇠기의 감쇠 특성을 조절하는 새로운 개념의 스마트 제진 시스템이다. 스마트 수동 제어 시스템에서 전자기 유도부는 영구자석과 솔레노이드 코일로 구성되며, 기존 스마트 제진 시스템의 계측기, 제어기, 외부 전원장치를 한꺼번에 대체할 수 있다. 면진 건물에 대한 스마트 수동 제어 시스템의 내진 성능을 수치적으로 검증하기 위하여 미국토목학회에서 제시한 면진 건물에 대한 벤치마크 제어 문제를 활용하였다. 스마트 수동 제어 시스템의 제진 성능을 MR 감쇠기를 이용한 기존 스마트 제어 시스템의 성능과 비교하였다. 수치 모의실험 결과를 통해 스마트 수동 제어 시스템이 면진 건물의 내진 성능을 개선하는 데 매우 유용함을 확인하였다.