        403.
        2004.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to examine the effect of the angle of a wedged insole on knee varus torque during walking. Fifteen healthy subjects were recruited. Knee varus torque was measured using three-dimensional motion analysis (Elite). Knee varus torque was normalized to gait cycle (0%: initial contact; 100%: ipsilateral initial contact) and stance phase (0%: initial contact; 100%: ipsilateral toe off). The average peaks of knee varus torque during the stance phase of the gait cycle according to the different insole angles (10 or 15 degrees) were compared using one-way ANOVA with repeated measures. The results showed that in the early stance phase, the average peak knee varus torque increased significantly for both the medial 10 and 15 degree wedged insole conditions and decreased significantly for both the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p<.05). However, there were no significant differences between the 10 and 15 degree wedged insole conditions with either the medial or lateral wedged insole (p>.05). In the late stance phase, the average peak knee varus torque increased significantly for the medial 10 and 15 degree wedged insole conditions (p<.05), but not for the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p>.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and lateral compartment forces in the knee varus-valgus deformity. Further studies of the effects of wedged insole angle on knee varus torque in patients with medial-lateral knee osteoarthritis are needed.
        4,200원
        409.
        2002.10 구독 인증기관 무료, 개인회원 유료
        The compatibility of exchange data has been the problem of CAD/CAM systems since the very beginning. National and international organizations have addressed the issue through development and release of standards for the exchange of geometric and non-geometric design data. CAD/CAM vendors are in charge with the task of interpreting and implementing these standards into their products. This paper explores an area of CAD/CAM systems development, which deals with effective exchange standards translators’ implementation. We introduce the new approach, which proposes to enclose all the translation operations concerning each exchange format to a separate DLL, thus making a “plug-in.” Later this plug-in could be used together with the CAD/CAM system or with specialized translation software. This approach allows rapidly creating new translators and gaining the reliable, high-efficiency, and, what is important, reusable program code. All examples come from the authors’ practice experiences of dealing with CAD/CAM systems.
        4,000원
        410.
        2002.10 구독 인증기관 무료, 개인회원 유료
        The accuracy of rotation of spindle unit could be defined as the stability of its spindle axis while rotating. The rotation in the rolling bearings causes the disturbing influence, which leads to the oscillation of a rotation axis. The main source of oscillation is the interaction between rolling bodies and rings’ races. The first oscillation source investigated was the out-of-shape imperfection of inner bearing ring. It was shown that it is possible to considerably decrease the radial runout of spindle if we can orient the inner rings in such a manner that oscillations caused by them would mutually compensate each other. Also the outer ring harmonics were explored as the second oscillation source. It was found that it is possible to reduce the runout by making the oscillation antiphased by mutually adjusting position of bearings on assembly stage.
        4,000원
        415.
        1991.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        저자 중 박성호에 의해 주로 채집된 700여점의 꽃파리류를 동정한 결과, 1 한국미기록속 및 6 한국미기록종을 포함 총 19속 38종으로 밝혀졌다. 따라서 한국산 꽃파리과는 총 26속 112종이 된다.
        4,200원
        416.
        2019.10 KCI 등재 서비스 종료(열람 제한)
        In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were 0.25 m3/s and 1.08 m3/s , respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.
        417.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        인공지능에 대한 관심이 높아짐에 따라 의료분야에서도 활발하게 인공지능이 연구되고 있다. 현재 국내에서는 엑스선 촬영, 컴퓨터단층촬영(Computer Tomography), 자기공명영상(Magnetic Resonance Imaging) 등의 의료영상장치에 인공지능이 접목되고 있으며 향후 방사선사 없이 환자의 방사선 영상을 획득 할 수 있는 인공지능을 탑재한 의료기기가 발명 될 것으로 예상된다. 본 연구는 엑스선 촬영에 있어서 환자 위치잡이에 대한 자동화에 대해서 초기 연구를 했다. 위치잡이에 대한 평가를 위해 엑스선 장비와 인체 팬텀을 사용했다. 프로그램은 Visual Studio 2010 MFC로 구현했으며 영상은 1,450 × 1,814 크기로 했다. 픽셀 값을 눈으로 식별 가능한 0 ~ 255 값을 갖는 명암으로 변환하여 모니터에 출력했다. 출력한 영상에 세 픽셀 좌표 값을 통해 각도를 예측하고 각도에 따른 음성안내에 따라 환자가 바른 위치잡이를 하도록 유도하는 절차 알고리즘 프로그램을 개발 했다. 다음 연구에서는 사용자가 좌표의 기준을 인공지능에게 전달하는 것이 아닌 인공지능 스스로 구조물을 파악하여 각도를 계산하는 연구를 진행할 것이다. 향후 위치잡이의 자동화를 통해 촬영부터 위치잡이까지 인공지능이 실시하도록 하는 연구에 도움이 될 것으로 예상된다
        418.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        현재 우리나라의 암 사망률 중 가장 높은 암은 폐암이며 조기발견이 어려운 대표적인 암이다. 조기 발견을 위하여 저선량 흉부 CT를 활용하고 있으며 이는 일반 흉부 X선 사진에 비해 약 3배 정도 폐암 진단율이 높다. 그러나 저선량 흉부 CT는 영상 해상도가 크게 저하될 뿐 아니라 신호가 약해 잡음에 민감한 단점이 있다. 또한 공기로 채워져 있는 폐는 밀도가 낮은 장기로 잡음의 유무가 암의 조기 진단에 영향을 크게 줄 수 있다. 본 연구는 Visual C++을 이용하여 2.0밀도를 가진 큰 원 내부에 물의 밀도인 1.0을 값을 갖는 원을 설정하고 그 안에 각각 밀도가 다른 작은 5개의 원을 수학적 팬텀화하고 가우시안 노이즈를 1%, 2%, 3%, 4% 각각 발생시켜 밀도차에 의한 노이즈의 영향을 평균 값과 표준편차 값, 신호대잡음비(SNR)로 확인하였다. 1% 노이즈 발생 시 큰 원과 작은 원의 밀도차가 가장 큰 영역의 SNR은 4.669로 노이즈의 영향이 작게 나타났으며 밀도차가 가장 낮은 영역의 SNR은 1.183으로 노이즈의 영향이 크게 나타났다. 또한 음의 밀도차에서도 같은 결과 값을 얻었으며 양의 밀도와 음의 밀도 모두 큰 원과 작은 원의 밀도차이가 높은 경우에 SNR 값이 높은 것을 확인 할 수 있다. 화질 또한 밀도차가 크게 나타났을 때 확연하게 육안으로 확인할 수 있었으며 노이즈레벨이 증가하는 경우에는 SNR이 감소하여 잡음의 영향이 크게 나타났다. 이는 밀도차가 적은 장기 또는 암과의 밀도가 비슷한 영역의 장기는 노이즈 영향이 크게 나타날 것이며 노이즈의 발생 확률에 따른 밀도차이의 영향이 진단에 영향을 끼칠 것으로 사료된다.
        419.
        2018.04 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        Gluten proteins play a key role in the unique baking quality of wheat by determining the water absorption capacity, cohesivity, viscosity, and elasticity of the dough. However, gluten from wheat, barley, rye, and oat can induce gluten sensitivity as well as celiac disease in susceptible populations. Hence, the gluten levels in foods labeled “gluten free” should be monitored. In this study, gluten-containing samples (sample: 600 g, water: 390 g) were treated with the commercial enzyme Protamex® (0.1-0.3% of sample weight) for 1-4 h and then measured with three ELISA kits. In the more viscous sample after treatment with 0.1% Protamex® for 1 h, the measured gluten contents were 1,802.6, 1,718.6, and 1,698.7 mg/kg using the G12, GLUTEN-CHECK, and Wheat/gluten (Gliadin) ELISA kits, respectively. The sample treated with 0.3% enzyme for 4 h had a lower viscosity (32.2 cps), and all three kits gave its gluten content as around 8.4 mg/g. When gluten breaks down, it does not act as gluten and its degradation is due to the enzyme. However, even when Protamex® was used at the same concentration for the same time, the measured values seem to be different for samples with and without the final heating treatment.
        420.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        A 40-year-old G1 P0 L0 A1 woman was referred to our clinic with 6-year history of infertility. Before visiting the clinic, she had 3 cycles of In-Vitro Fertilization (IVF) procedures (2 cycles of Controlled Ovarian Stimulation-IVF and 1 cycle of frozen-thawed Embryo Transfer (ET)) at other clinic. She had medical history of abortion at early gestation following FET (frozen-thawed-ET). The patient had complete type of septate uterus, double cervix and longitudinal vaginal septum. Vaginal septotomy was done first and 1 month later, hysteroscopic septoplasty was followed using ballooning filled with dye. After septoplasty, we inserted ballooning and left for several days to compress septal endometrium on the septectomy area. All procedures were done in the ambulatory operating room without laparoscopy or admission. 3 months later, she had in vitro fertilization-embryo transfer (IVF-ET) and FET procedures in our clinic. She had successful pregnancy and now is at 22 weeks of gestation. New ambulatory septoplasty using dye-filled ballooning is easy, safe and minimally invasive surgery for treatment of complete septate uterus.