This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.
In this study, the seismic performance and behavior characteristics of the upper truss structure of the large stadium are analyzed by nonlinear dynamic analysis. In the nonlinear dynamic analysis, the earthquake records were generated by site response analysis to simulate the nonlinear behavior of the relevant soil condition where the structure is located. Nonlinear dynamic analysis was performed using Perform-3D and the nonlinear properties of the substructure and the superstructure were determined in accordance with KISTEC guideline. According to the analysis results, excessive deformation occurred in the upper truss element, and plastic hinges exceeded the target performance in some members. Buckling-restrained brace is used for seismic retrofit of stadium structures and the analysis results shows the interstory drift satisfies the target performance level with dissipating the seismic energy efficiently.
식품으로부터 다양한 병원 미생물을 신속 검출하기 위하여 다양한 검출 원리를 이용한 키트들이 개발·시판되고 있다. 검사키트는 신속, 정확하고 간단하게 사용할 수 있으므로 검사기관이나 실험실 뿐 아니라 식품회사에서 QC 또는 QA를 수행하기 위하여 사용이 증가되고 있는 추세이다. 이에 본 연구에서 E. coli O157:H7의 단클론항체를 이용하여 면역크로마토그래피법에 의해 개발한 E. coli O157:H7 검출 키트(Donga Co, Korea, D-kit)에 대한 검출감도 및 특이성을 확인하고 식품 시료에 적용 가능성을 평가하였다. 면역크로마토그래피법에 의해 개발?시판되고 있는 Reveal E. coli O157:H7 (Neogen Co., USAm R-kit)와 VIP EHEC kit (Biocontrol INC., USA, V-kit)를 비교 키트로 사용하였다. E. coli O157:H7 표준균주를 사용하여 실시한 검출감도 확인시험 결과 R-kit 및 D-kit는 104/㎖의 농도에서 양성으로 확인되었고 10³/㎖에서도 약한 양성 반응을 보였으나, V-kit는 10?/㎖ 농도로 검출감도가 낮았다. 또한 배양액을 가열하여 kit에 적용하는 것이 가열하지 않은 경우보다 검출감도를 높일 수 있었다. E. coli O157:H7 분리 22주, verotoxin 생성 E. coli 7주 E. coli 분리주 40주 및 38종의 장내세균에 대한 특이성 시험 결과 세 가지 키트 모두에서 동일한 결과를 보였는데, 시험균주 107주 중 3주를 제외한 모든 균에서 음성의 결과를 보여 특이성을 확인하였다. 세 키트에 위양성 반응을 보인 것은 E. coli O157:H19, E. coli O157:H18 및 Salmonella galinarium으로 이들 혈청형과 O157:H7 사이에는 유사한 혈청학적 특성이 존재하는 것으로 추정되었다. 이상의 실험결과로 D-kit는 E. coli O157:H7을 검출하는데 감도 및 특이성 면에서 기존 키트인 R-kit 및 V-kit와 같이 유용한 것으로 확인되었다.