검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study conducted field surveys targeting benthic macroinvertebrates and fish in Andong Dam and Yeongsan River, with the specific aim of analyzing bluegill stomach contents. Bluegills in Andong Dam ranged from 40-220 mm, with 93.0% between 80-220 mm, while those in Yeongsan River ranged from 50-210 mm, with 71.4% between 120-210 mm. The highest feeding rates in both sites were for Chironomidae spp., with findings of 72.6% in Andong Dam and 80.4% in Yeongsan River. In Andong Dam, H. nipponensis and Baetidae sp. were also significant at 17.5% and 6.5%, respectively, while in Yeongsan River, Baetidae sp. (7.5%) and Hymenoptera sp. were the next most common at 3.8%. The EI index showed that bluegills generally avoided H. nipponensis and S. tsuchigae (-0.373 and -0.975) whereas they preferred Chironomidae spp. (0.759, 0.892) and Baetidae sp. (0.723). The parameter b values of the total length-weight relationship of bluegill were calculated as 3.452 in Andong Dam and 3.449 in the Yeongsan River, respectively. The slope values of the condition factor were 0.0067 in Andong Dam and 0.0065 in the Yeongsan River. Both values were positive, indicating that the nutritional status of bluegill was good. Aquatic insects constituted the primary food source, particularly in Yeongsan River. Feeding patterns did not significantly differ by habitat orientation groups, but Yeongsan River bluegills consumed more diverse food sources. In Andong Dam, larger bluegills likely consume food sources with larger biomass, while Yeongsan River’s diverse and abundant food sources support opportunistic feeding tailored to the water ecological environment.
        4,600원
        2.
        2017.04 서비스 종료(열람 제한)
        In this study, the effect of electromagnetic wave from an electronic device on electric sensor system and optic sensor were analyzed to verify the reduction effect of a optic sensor and applicability to marin structure. Test revealed that optic sensor system was not occurred the noise by electromagnetic waves also had the low range of fluctuation.
        3.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        In this study, the effect of electromagnetic wave from an electronic device on electric sensor system and optic sensor were analyzed to verify the reduction effect of a optic sensor and applicability to marin structure. Test revealed that optic sensor system was not occurred the noise by electromagnetic waves also had the low range of fluctuation.