Staphylococcus aureus is gram positive, facultatively anaerobic, non-sporulative coccus, and positive for coagulase and DNase. The food oisoning outbrealc of Staphylococcus aureus increases in the world, and third occurnn happened in our country. Of 105 isolates (25.4%) obtained 413 fecal samples of food-poisoning suspicious patients. In those cases, the enterotoxins were detected firom a total of 45 isolates (42.9%), 9 isolates(20.0%) were A type, 33 isolates (73.3%) we H types, 2 isolates (4.4%) were G type and 1 isolate was a I type enterotoxin. Among the isolates possessing staphylococcal enterotoxins, 29 isolates had H type only(64.4%), 5 isolates had A type only and 4 isolates had both A and H type. 'Iieo isolates had G type only and 1 isolate had I type only. In the antibiotic susceptibility, 48 isolates (46%) had at least one antibiotic resistance among 105 isolates, 34 isolates (70.8%) were resistant to penicillin, 1 isolate (2.1%) to ampicillin, 3 isolates (6.3%) to erythromycin and kanamycin. Seven were resistant to more than two antibiotics and especially 1 isolate was resistant to penicillin-ampicillin-nitrofurantoin.
한강 고수부지 및 지천인 안양천, 탄천, 중랑천변의 경작지에서 채집된 36종 285건의 농작물에 대한 Pb, Cr, Cd, Fe, Zn, Mn, Cu. Hg의 농도를 측정하고 그 결과를 채집 시기, 채집 지역 및 작물별로 비교, 분석한 결과, 작물 중의 중금속 함량은 평균치를 기준으로 볼 때 Fe(34.592 ppm)>Mn(11.071 ppm)>Zn(8.853 ppm)>Cu(1.795 ppm)>Cr(0.237 ppm)>Pb(0.100 ppm)>Cd(0.011 ppm)>Hg(0.003 ppm) 순으로 곡류 및 두류에서는 Zn의 함량이 Mn보다 높고, 채소류와 과실류에서는 Mn의 함량이 Zn보다 높은 양상을 나타냈다. 또한 각 지역에서 채취한 작물의 미량금속 함량의 경우 Fe은 0.004∼203.083 ppm, Cu은 0.017∼22.727 ppm. Mn은 0.000∼74.373 ppm. Zn은 0.080∼37.166 ppm으로 비교적 고농도로 존재하고 있는 반면 유해중금속류인 Pb은 0.000∼0.654 ppm, Cd은 0.000∼0.270 ppm, Cr은 0.000∼l.229 ppm, Hg은 0.000∼0.037 ppm으로 비교적 미량으로 존재함을 알수 있었다. 대상 농작물을 잎, 줄기, 뿌리, 열매로 분류하여 미량금속 함량을 분석한 결과, 분석 대상 금속의 농도가 잎>줄기>뿌리>열매의 순으로 나타났다. 무등의 뿌리 작물에 있어서 Pb은 잎(0.055 ppm))뿌리(0.035 ppm), Cr은 잎(0.118 ppm))뿌리(0.031 ppm), Cd은 잎(0.004 ppm)1뿌리(0.001 ppm), Hg은 잎(0.004 ppm))뿌리(0.001 ppm)으로 뿌리보다 잎에 많은 것으로 나타났는데 이러한 결과로 보아 뿌리는 금속 이온이 흡수되는 기관일 뿐 축적은 잎에 비해 상대적으로 적게 됨을 알 수 있었다.
This paper intends to investigate commercial fish and shellfish 25 species (fish 8 species, shellfish 7 species, crustacean 3 species, molusc 4 species and echinodermata) for the distribution of sanitary indicator organisms (total viable counts, coliforms, staphylococci, vibrios, and enterococci) and diatributional change of indicator organisms according to storage temperature and period. The logarithmic mean of total viable counts for total commercial fish and shellfish 25 species was 5.41±0.26 CFU/g, and in accordance with fish and shellfishes, crustacean 6.76±0.67 CFU/g, shellfish 5.67±0.56 CFU/g, echinodermata 5.47±0.50 CFU/g, fish 5.021±0.38 CFU/g, and mollusc 5.03±0.65 CFU/g. The logarithmic mean of enterococci was 2.36±0.37 CFU/g, and in accordance with fish and shellfish, crustacean 3.44±0.12 CFU/g, shellfish 3.87±0.45 CFU/g, echinodermata 3.38±0.0 CFU/g, fish 2.16±0.41 CFU/g and mollusc 0.01±0.0 CFUIg. The logarithmic mean of vibrios was 1.60±0.59 CFUIg, and in accordance with fish and shellfish, crustacean 4.23±0.11 CFU/g, shellfish 3.58±0.90 CFUIg, echinodermata 1.64±0.34 CFU/g, fish 1.79±0.67 CFU/g and mollusc 1.07±0.61 CFU/g. The logarithmic mean of staphylococci was 1.60±0.59 CFU/g, and in accordance with fish and shellfish, shellfish 0.01±0.00 CFU/g, echinodermata 3.51±0.60 CFU/g, fish 1.68±0.64 CFU/g, crustacean 0.34±0.33 and mollusc 2.90±0.11 CFU/g. The logarithmic mean of coliforma was 2.2±0.32 CFU/g, and in accordance with fish and shellfish, echinodermata 3.58±0.89 CFU/g was highest, shellfish 3.25±0.30 CFU/g, crustacean 3.23±0.49 CFU/g, fish 2.18±0.63 CFU/g, peeled shellfish 1.80±0.51 CFU/ g and mollusc 1.55±0.95 CFU/g. As the results of research of the change of the contaminated indicator microflora in working with storage period at 10℃, 20℃ and 30℃, total viable counts was increased without storage temperature and enterococci were decreased slowly at 10℃, but increased at 20 and 30℃ Vibrios were decreased slowly at 10℃, decreased at 20℃ and 30℃ in 2 days after increased rapidly. Staphylococci were increased promptly without storage temperature in 2 days, then the total viable counts were maintained. Coliforms were increased at 10℃ by 7 days, then decreased or maintained after 14 days, changed at 20℃ in accordance with fish species in 2 days, then returned to the initial total viable count, and decreased rapidly at 30℃ on 2 days. By the way, there were no difference among the species.
Many of the structures constructed since the 1970s have begun to deteriorate. As a result, safety inspection / diagnosis and maintenance are expected to increase further, and long-term and systematic measures are urgently needed to prepare for the aging of major infrastructures. Currently, the safety inspection and maintenance of the structure is carried out by the method based on the utilization of the measurement data and the manager's experience, but the reliability and the accuracy are still insufficient. In other words, there is a limit to understanding the state change of bridges, such as abnormal behavior and gradual damages, therefore, it is necessary to have an accurate and reliable monitoring process using new techniques and systems. For this reason, I would like to examine the possibility of using cloud and big data in the field of infrastructure safety management.
In this study, the effect of electromagnetic wave from an electronic device on electric sensor system and optic sensor were analyzed to verify the reduction effect of a optic sensor and applicability to marin structure. Test revealed that optic sensor system was not occurred the noise by electromagnetic waves also had the low range of fluctuation.
In this study, the effect of electromagnetic wave from an electronic device on electric sensor system and optic sensor were analyzed to verify the reduction effect of a optic sensor and applicability to marin structure. Test revealed that optic sensor system was not occurred the noise by electromagnetic waves also had the low range of fluctuation.