검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2021.01 KCI 등재 서비스 종료(열람 제한)
        The purposes of this study were to evaluate the removal characteristics of COD, Ni, and P and to derive appropriate operating conditions for the plating wastewater according to NaOCl reaction time and pH operating conditions in the BPC unit process during the plating wastewater treatment process. As a results of evaluating the removal characteristics for raw wastewater by each BPC unit process, the removal efficiencies of COD, Ni and P in BPC 1-1 unit process were 72.8%, 99.1%, and 100.0%. Therefore, the proper reaction time of NaOCl was derived as 21.1 minutes. In order to maintain the +800 mV ORP and the reaction time of 20 minutes, the temporary injection and continuous injection of NaOCl in the BPC unit process were 13.7 mL and 18.7 mL, respectively. It was found that the temporary injection method of NaOCl reduced the chemical cost by 36.5% compared to the continuous injection method. Also, Ni showed the highest removal efficiency of 97.8% at pH 10.5. On the other hand, P showed a removal efficiency of 57.4% at pH 10.0.
        2.
        2020.11 KCI 등재 서비스 종료(열람 제한)
        In this research, heavy metals and T-P removal characteristics of plated wastewater are derived using BPC(Break Point Chlorination) process. AA sedimentation pond outflow(Influence) was evaluated for the removal efficiency of heavy metal(Ni) and T-P at a reaction time of 25 minutes by NaOCl input volume(9, 11, 13 and 15 mL). In the case, the higher the NaOCl input volumes, the higher the ORP values were maintained and the higher the removal efficiency tended to be. On the other hand, T-P was judged to have a low relationship between the ORP value and the removal efficiency. In addition, the efficiency of removal heavy metals and T-P in the plated wastewater by injecting 10 mL, 15 mL, 20 mL and 25 mL NaOCl, increased as the amount of NaOCl injected increased, the amount of NaOH input for pH increased. It was found that suspended solid in effluence also increased. It was also observed that the color of the plating wastewater changed from yellowish green to green to charcoal gray to black as the amount of NaOCl injected increased. Treatment characteristics of the reaction time, the longer the reaction time with the substance to be treated after the input of NaOCl, the more the heavy metal removal efficiency tended to increase. Through XRF analysis of the sludge, the constituents in the sludge such as NaCNO, CNCl, Na3PO4, CrO4, 2Na2CrO4 and 2NaNO3 will be analyzed in detail, and the mechanisms of the reaction between the plated wastewater and the complex compound will be elucidated.
        3.
        2018.05 서비스 종료(열람 제한)
        우리나라에서 폐기물을 처리하는 방법에는 크게 매립, 소각, 재활용이 있으며 일반적으로 폐기물을 수거하여 재활용 할 수 있는 부분을 제외한 나머지는 소각한 뒤 매립을 하는 방식을 택하고 있다. 매립은 계속적인 매립지 확보에 어려움을 겪고 있으며 폐기물의 배출량이 갈수록 증가됨에 따라 예상되는 매립지의 기대수명이 점점 감축되고 있다. 이러한 상황에서 우리나라에서는 폐기물을 짧은 시간 안에 매우 안정적으로 처리할 수 있는 소각기술로 시야를 넓혀야 한다. 소각은 대부분 재활용할 수 있는 폐열 및 고형화연료를 확보할 수 있을뿐더러 매립지의 수명도 효과적으로 늘릴 수 있다. 또한 소각이 완료된 후의 소각재는 수분까지도 거의 제거된 상태이기 때문에 바로 매립이 가능한 정도에 이르렀다. 환경부에서 발행한 ‘전국 폐기물 발생 및 처리 현황(2015년도 수정본)에 따르면 소각과정에서 발생된 연소재의 일일배출량은 점점 증가하는 추세이다. 따라서, 소각재를 매립하는 방법 외에 재활용할 수 있는 방안을 모색하여 매립지의 수명연장은 물론 효율적인 재활용자원으로 사용할 수 있게 만드는 것이 필요하다. 그러나 소각재는 현행 폐기물 관리법상 중금속 농도가 비교적 낮기 때문에 일반폐기물로 관리되고 있었으나 유해성 논란이 끊이질 않고 있다. 따라서, 소각재에 들어있는 유해중금속의 농도를 효과적으로 처리하여 낮추면 다른 분야에서 즉각 활용할 수 있는 좋은 재료로 사용할 수 있을 것이다. 본 연구에서는 소각재의 처리 실태를 알아보고 재활용되고 있는 방법들을 검토, 비교하고 현재 유동상식 소각로에서 배출되는 폐유동사의 재생골재로의 재활용 가능성에 대해 알아보았다. 추가적으로 유동상식 소각로에서 배출되는 보일러재와의 배합 가능성, 그리고 성분분석을 이용한 함유성분의 함량과 재활용 목표의 관계도 연구하였다. 이는 기존에 활용되고 있는 재활용 방법과 새롭게 이용할 수 있는 방법에서 원재료로 사용되고 있는 것들을 대체할 수 있는가에 대한 것이다. 기존에 사용되고 있는 원재료만큼의 효율이 나온다면 원가절감은 물론 폐기물 재활용, 나아가서는 자원재이용에 따른 환경문제 감소에 도움이 될 수 있을 것이라 판단된다.