검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach 180 oC, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.
        2.
        2018.05 서비스 종료(열람 제한)
        폐기물에너지는 폐기물을 변환시켜 연료 및 에너지를 생산하는 기술이며 고형연료제품이 이에 해당한다. 고형연료제품은 가연성 생활폐기물, 폐플라스틱, 폐타이어, 폐목재 등의 고체폐기물을 파쇄, 분리, 건조, 성형 등의 공정을 거쳐 제조한다. 고형연료제품 사용은 폐기물 발생을 최소화할 수 있고 폐기물 중 가용 자원의 재활용을 극대화 할 수 있는 장점이 있다. 하지만 고형연료제품은 소각을 통해 열에너지를 회수하므로 그 과정에서 오염물질이 발생하는 단점이 있다. 따라서 오염물질 발생을 줄이기 위해 고형연료제품의 품질기준에 적합한 제품을 사용해야 할 것이다. 고형연료제품의 품질기준 시험은 환경부고시 제 2014-135호 󰡔고형연료제품 품질 시험․분석방법󰡕을 기준으로 수행한다. 따라서 품질기준 적합성 여부를 판단하기 위해서는 고형연료제품 품질시험방법의 정확성이 요구된다. 하지만 현행 고형연료제품 품질시험방법은 국외 고형연료제품 품질시험방법과 폐기물공정시험기준을 참고하여 번역․제정하였고, 그 과정에서 국내 실정에 맞지 않거나 용어, 문장의 오류가 다수 발견되었다. 그러므로 현행 시험방법을 개선하고 오류를 수정하여 고형연료제품 품질시험방법을 개정해야 할 필요가 있다. 본 연구에서는 품질시험방법의 개정을 위해 고형연료제품 품질표시 시험기관의 의견을 수렴하였고 개정의견의 타당성은 전문가 회의, 적용성 시험을 통해 검토하였다. 적용성 시험은 고형연료제품 시료 운반 온도에 따른 성분 변화 분석, 회분시험 시료량의 변화에 따른 회분함량 분석, 마이크로파 전력 및 반응시간에 따른 고형 연료제품의 중금속 함량 변화 분석을 수행하였다.
        3.
        2017.11 서비스 종료(열람 제한)
        국내 폐기물 발생량은 급격한 산업화와 인구 증가 등의 요인으로 인해 꾸준히 증가하고 있으며 이에 따라 다양한 폐기물 처리방법이 수행되고 있다. 폐기물 처리방법 중 하나인 고형연료제품 제작은 폐기물 발생을 최소화할 수 있고 폐기물 중 가용 자원의 재활용을 극대화 할 수 있기 때문에 신재생에너지로 간주되고 있다. 고형연료는 고체폐기물 중 폐합성수지류, 폐지류, 폐목재류 등 가연성 물질을 선별하여 파쇄, 건조 등의 처리과정을 거쳐 연료화시킨 것을 통칭하며 소각시설이나 발전시설에서 연료로 사용되고 있다. 하지만 최근 미세먼지 문제가 심각해지면서 고형연료에 대한 부정적 인식이 늘고 있으며 이를 극복하기 위해서는 고형연료가 안전한 제품으로 인식될 수 있도록 다수의 품질기준 적합성 검사가 필요하다. 고형연료 품질기준 중 중금속 함량 분석은 이러한 인식 제고에 반드시 필요한 시험 항목이기 때문에 정확성이 확보되어야 하며 현재 고형연료 품질시험방법에 따른 중금속 분석방법은 전처리 과정에서 고형연료 시료가 완전히 분해되지 않는 문제점이 발견되었다. 본 연구에서는 기존 고형연료의 중금속 함량 분석 방법을 개선하기 위해 마이크로파 전처리 조건의 산 종류, 마이크로파 전력(W), 반응시간에 변화를 주어 이에 따른 17종의 중금속(As, Cd, Pd, Ca, Co, Cr, Cu, Fe, Li, Mg, Mn, Ni, Sb, Sr, Ti, V, Zn)함량 변화를 확인하였다. 대상 시료는 인증표준물질 ERM-EC680k를 사용하였고 마이크로파 전처리를 통해 제조된 액상시료는 유도결합플라즈마 분광분석기(ICP-OES)를 통해 분석하였다.
        4.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        Emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurnas (PCDFs) in stack gas were analyzed from 21 municipal solid waste incinerators (MSWs) using high resolution gas chromatography equipment with a high resolution mass spectrometer (HRGC/HRMS) in 2015. The concentration of PCDDs/DFs was in the range 0.09 ~ 354.54 pg-TEQ/Sm3 based on the International Toxicity Equivalency Factor (I-TEF) and all MSWs complied with emission standards. The congener distribution of PCDDs/DFs was categorized into one group and two outliers via principal component analysis (PCA). Among the 17 PCDDs/DFs, 1,2,3,4,6,7,8-HpCDD showed the highest mass fraction (20.8%) and 2,3,4,7,8-PeCDF showed the largest TEQ contribution (42.9%).
        5.
        2017.05 서비스 종료(열람 제한)
        급격한 산업화와 인구 증가 등은 국내 폐기물 발생량이 해마다 증가하는 요인으로 작용하고 있으며 이에 따른 다양한 폐기물 처리방법이 수행되고 있다. 대표적인 폐기물 처리 방법 중 하나는 소각에 의한 폐기물 처리이며 다량의 폐기물 처리가 가능하고 특히 폐기물의 부피와 무게를 10~20% 정도로 감량할 수 있으며 소각열에너지를 회수하여 폐기물의 자원순환에 일조하고 있다. 이러한 장점으로 인해 국내 폐기물의 소각처리 비율은 꾸준히 증가하고 있는 추세이다. 그럼에도 불구하고 폐기물 소각처리 중 발생하여 배출되는 다양한 오염물질은 환경에 큰 단점으로 작용할 수 있다. 따라서 소각시설에서 배출되는 오염물질의 모니터링은 환경보전 문제에 있어 매우 중요한 과제이다. 본 연구에서는 소각로에서 배출되는 오염물질의 특성을 파악하기 위해 의료 폐기물 소각로 44개소와 소형 폐기물 소각로 28개소, 총 72개의 가스 샘플을 채취하고 분석하여 주 대기오염 물질인 이산화탄소, 질소산화물, 황산화물, 다이옥신을 측정하였고 배출허용기준과 비교하였다. 또한 주성분분석을 통해 오염물질 배출을 6개 그룹과 6개 샘플로 나누어 각각의 배출특성을 분석하였다. 분석 결과, 다이옥신의 경우 배출허용기준을 초과한 시설은 의료 폐기물 소각로 7개소, 소형 폐기물 소각로 9개소로 나타난 반면, 이산화탄소, 질소산화물, 황산화물의 경우 소형 폐기물 소각로 10개소에서만 배출허용기준을 초과한 것으로 나타났다. 이 결과를 통해 의료 폐기물 소각시설보다 소형 폐기물 소각시설의 오염물질 배출이 심각한 것으로 확인되었으며 방지시설과 운전 조건의 개선이 필요할 것으로 판단된다.
        6.
        2017.04 KCI 등재 서비스 종료(열람 제한)
        Among the unintentional persistent organic pollutants (UPOPs), polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) were measured from a stack of 28 small-scale waste incinerators (SWIs) from 2013 to 2015. The emissions of PCDDs/PCDFs ranged from N.D. to 208.3 ng-TEQ/Sm3 with an average of 21.1 ng-TEQ/Sm3 based on the International Toxicity Equivalency Factor (I-TEF). The 28 stack gas samples were categorized into four types and evaluated by the score plot of principal component analysis (PCA). Furthermore, 17 PCDD/PCDF congeners were divided with the number of chlorine substitutions by a loading plot. The correlations between PCDDs and PCDFs were also estimated. The emissions of PCDDs/PCDFs from 19 SWIs were below the emission standards, while nine SWIs significantly exceeded them in this study.
        7.
        2016.11 서비스 종료(열람 제한)
        잔류성유기오염물질(Persistent organic pollutant)은 안정성이 높아 잘 분해되지 않으면서 동시에 강한 독성을 가진 물질이기 때문에 대부분의 국가에서 배출량을 규제하고 있다. 주로 POPs라고 일컫는 이 물질들 중에 다이옥신은 대표적인 비의도적 잔류성유기오염물질이며 그에 따라 많은 연구가 진행되어 왔다. 다이옥신은 PCDD(Polychlorinated dibenzo-p-dioxin), PCDF(Polychlorinated dibenzofuran)의 congener를 통상적으로 지칭하며 염소의 치환 위치와 수에 따라 총 75개의 PCDD, 135개의 PCDF가 존재한다. 그 중 독성을 가진 17개의 다이옥신 congener에 대한 안정성 연구를 순이론적 계산의 일종인 DFT(Density functional theory) 계산을 통해 수행하였다. DFT 계산은 Gaussian09W software를 통해 수행하였으며 B3LYP/cc-pvdz, B3LYP/6-311+G(d,p) level로 구조 최적화와 진동수를 계산을 하였다. 17개의 다이옥신 congener는 모두 평면 구조를 이루고 대칭성에 따라 각각 D2h, C2v, C2h, Cs 의 point group으로 최적화 되었다. 계산 결과를 통해 얻은 열역학적 특성과 HOMO (Highest occupied molecular orbital)-LUMO(Lowest occupied molecular orbital)를 통해 다이옥신 congener의 생성엔탈피, 생성자유에너지, 엔트로피, 이온화포텐셜, 전자친화도 값을 도출하였고 안정성을 잔류성과 연관 지어 평가하였다. 본 계산 연구는 추후 다이옥신 배출 자료와 비교를 통해 congener 패턴을 예측하는 연구를 수행하는데 도움이 될 것이다.