Human stampedes were a major hazard that could occur during mass gatherings, but they have received limited attention in korea. However, after the 10.29 Itaewon disaster, this atmosphere has turned around. The cause of such an accident and how to prevent it should be considered. The main aim of this study is to identify the reason why did the accident happen at that time, the root cause, and the triggering cause with Delphi-AHP survey method. In addition, various preventive measures were investigated by experts to prevent accidents similar to 10.29 Itaewon disaster. Problems and solutions were presented by collecting expert opinions on the causes and preventive measures of the 10.29 Itaewon disaster. However, the opinion of the experienced peoples who experienced the risk at the Itaewon was not included, so further investigation is considered necessary.
In this study, AlSi10Mg alloy powders are synthesized using gas atomization and sieving processes for powder bed fusion (PBF) additive manufacturing. The effect of nozzle diameter (ø = 4.0, 4.5, 5.0 and 8.0 mm) on the gas atomization and sieving size on the properties of the prepared powder are investigated. As the nozzle diameter decreases, the size of the manufactured powder decreases, and the uniformity of the particle size distribution improves. Therefore, the ø 4.0 mm nozzle diameter yields powder with superior properties. Spherically shaped powders can be prepared at a scale suitable for the PBF process with a particle size distribution of 10–45 μm. The Hausner ratio value of the powder is measured to be 1.24. In addition, the yield fraction of the powder prepared in this study is 26.6%, which is higher than the previously reported value of 10–15%. These results indicate that the nozzle diameter and the post-sieve process simultaneously influence the shape of the prepared powder as well as the satellite powder on its surface.
Previous studies have reported that deep neck flexor (DNF) exercise can improve neck problems, including neck pain, forward head posture, and headache, by targeting the deep and superficial muscles of the neck. Despite the prevailing opinion across studies, the benefits of DNF can vary according to the type of neck problems and the outcome measures adopted, ranging from positive outcomes to non-significant benefits. A meta-analysis was conducted in this study to assess conclusive evidence of the impact of DNF exercise on individuals with neck problems. We used PUBMED, MEDLINE, NDSL, EMBASE, and Web of Science to search for primary studies and the key terms used in these searches were “forward head posture (FHP),” “biofeedback,” “pressure biofeedback unit,” “stabilizer,” “headache,” and “neck pain.” Twenty- four eligible studies were included in this meta-analysis and were coded according to the type of neck problems and outcome measures described, such as pain, endurance, involvement of neck muscle, craniovertebral angle (CVA), neck disability index (NDI), cervical range of motion (CROM), radiographs of the neck, posture, strength, endurance, and headache disability index. The overall effect size of the DNF exercise was 0.489. The effect sizes of the neck problems were 0.556 (neck pain), –1.278 (FHP), 0.176 (headache), and 1.850 (mix). The effect sizes of outcome measures were 1.045 (pain), 0.966 (endurance), 0.894 (deep neck flexor), 0.608 (superficial neck flexor), 0.487 (CVA), 0.409 (NDI), and 0.252 (CROM). According to the results of this study, DNF exercise can effectively reduce neck pain. Thus, DNF exercise is highly recommend as an effective exercise method for individuals suffering from neck pain.
Background:Individuals with spinal cord injury (SCI) rely on their upper limbs for body-lifting activity (BLA). While studies have examined the electromyography (EMG) and kinematics of the shoulder joints during BLA, no studies have considered foot position during BLA.Objects:This study compared the effects of different foot positions during BLA on the shoulder muscle activities, peak plantar pressure, knee flexion angle, and rating perceived exertion in individuals with SCI.Methods:The study enrolled 13 mens with motor-complete paraplegic SCI, ASIA (American Spinal Injury Association) A or B. All subjects performed BLA with the feet positioned on the wheelchair footrest and on the floor independently. Surface EMG was used to collect data from the latissimus dorsi, pectoralis major, serratus anterior, and triceps brachii. The peak plantar pressure was measured using pedar-X and the knee flexion angle with Image J. Borg’s rating perceived exertion scale was used to measure the physical activity intensity level. The paired t-test was used to compare the shoulder muscle activities, peak plantar pressure, knee flexion angle, and rating perceived exertion between the two feet positions during BLA.Results:The activity of the latissimus dorsi, pectoralis major, serratus anterior, and triceps brachii and rating perceived exertion decreased significantly and the peak plantar pressure and knee flexion angle increased significantly when performing BLA with the feet positioned on the wheelchair footrest compared with on the floor (p<.05).Conclusion:These findings suggest that individuals with SCI may perform BLA with the feet positioned on the wheelchair footrest for weight-relief lifting to decrease the shoulder muscle activities and the rating perceived exertion and to increase the peak plantar pressure and the knee flexion angle.
The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder
passive range of motion measurement using the “Clinometer + bubble level”, a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at 90° abduction; ER90 and internal rotation at 90° abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75∼.87] and excellent in ER90 [ICC (2,1)=.90∼.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.
Foot posture is important in the development of the musculoskeletal structure in the lower limbs because it can change the mechanical alignment. Although foot orthotics are widely used for the correction of malalignments in the lower extremities, the biomechanical effects of wedges have not yet been cleared. The aim of this study was to investigate whether medial wedges affect the electromyographic (EMG) activity of the knee and hip joints in healthy adults that are performing one leg standing. Seventeen healthy volunteers performed the one leg standing under two foot conditions: A level surface, and a medial wedge. The subjects' EMG data for the gluteus maximus (Gmax), gluteus medius (Gmed), tensor fasciae latae (TFL), biceps femoris (BF), vastus lateralis (VL), and vastus medialis oblique (VMO) were recorded, along with the surface EMG, and all were analyzed. The EMG activity of the Gmed and TFL had significantly decreased under the medial wedge condition during one leg standing. Further study is needed in order to investigate whether medial wedges influence the EMG activity and kinematic data of the knee and hip joints as well as the ankle joints in adults with flexible flatfoot, while they are performing one leg standing.