        검색결과 4

        1.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated Extremely Low Frequency-Magnetic Fields (ELF-MF) exposure levels among housewives for a 24-Hour activity pattern to identify related factors for the exposures. To achieve the objective of the study, we surveyed ELF-MF levels using EMDEX II in a living environment from January to December 2016. We also made subjects write a Daily Activity Pattern in order to identify durations for staying and related information in the environment of exposures. Subjects showed that they spent the longest time in sleep and at home, at 487.5 minutes (KOSIS: 479.0 minutes) and 472.1 minutes (KOSIS: 428.0 minutes), respectively. Furthermore, the 24- hour time-weighted average (TWA) of 54 housewives was 1.24 ± 3.48 mG (GM: 0.52 mG). The ELF-MF exposure levels for all Multiuse Facilities were far below the recommended standards of EMF Guideline Korea and ICNIRP. Thus, these results will provide useful data for the determination of ELF-MF management and reduction methods in living environments.
        4,000원
        2.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the level of ELF-MF emissions from underground cable lines near daycare centers in the metropolitan city of Seoul. We investigated 143 daycare centers from June to September of 2015. In addition, the rate of reduction of ELF-MF levels according to the distance from the line was calculated using simulations. The ELF-MF emission level of 143 daycare centers at boundary point was 1.37 ± 1.75 mG (GM: 0.75 mG) and at direct point was 11.14 ± 17.99 mG (GM:6.05 mG). ELF-MF levels at direct point were 8.13 (arithmetic mean) and 8.06 (geometric mean) times higher, respectively, than that at the boundary point. By analyzing the relationship between ELF-MF and electricity current (A) and operating depth (m), a significant correlation was found between ELF-MF and current (A) and depth (m), at 0.360 (p<0.01) and -0.303 (p<0.05), respectively. The results of the simulation showed that appropriate separation distances showing below 4 mG was 8m and 14m, adjusted mean current (A) and maximum current (A), respectively. The results of the study suggest that a plan should be implemented for the management of ELF-MF in High voltage power-line and Underground cable line areas, through a broad and detailed survey and risk communication.
        4,000원
        3.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, ELF-MF levels of subway trains were measured to understand the status of the intensity of ELFMF. The measurement points for the train are selected in the center of each train compartment(pantagraph compartment, motor-driven compartment and the compartment that is not connected to any other electric equipment) using EMDEX II. ELF-MF levels of trains were measured from the starting to the terminal station in each lines(Seoul line 1-9, Incheon line 1, Incheon international airport line, Gyungui line, Bundang line, Gyeongchun line, Joongang line, Suin line). We found that the mean and range of ELF-MF levels in the DC power subway train are 2.4 and 0.1~125.9 mG, respectively, while the mean and range of ELF-MF levels in the AC power subway train are 10.4and 0.0~156.3 mG, respectively. Furthermore, the maximum ELF-MF level(156.3 mG) was lower than the reference level(ICNIRP 833 mG, 60Hz). The findings of this study in relation to the characteristics of ELF-MF for subway will be useful to derive the ELF-MF exposure coefficient from our living environment in a subsequent study.
        4,000원
        4.
        2013.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The light trespass problem still has not been solved for a long time because of the complex influences of the reflection or overlap lights. To solve the light trespass problem, the assessment of the characteristics of the spilt light carry out firstly. In this study, we estimated the light trespass reducing performance of various load lightings using by RELUX lighting simulation program. In the simulation program, we designed the lighting environment according to the streetlight installation guideline by the ministry of land, transport and maritime affairs. And we estimated the light trespass caused by roadway lighting from first floor position to fourth floor position. And we compare the light trespass caused by back light of the roadway lighting with the light trespass caused by forward light. Then we estimated the effect of light trespass by improving the light distribution of roadway lighting from Backlight rating 3 to Backlight rating zero. From the research, we find that the light trespass caused by roadway lighting maximize at the first floor position of the house. And the light trespass contribution rate by backlight and forward light is 66 percentage and 33 percentage respectively. And we estimated that the light trespass can be decreased about 40 % by improving the backlight. The result derived from this research will be helpful to establish the light pollution reduction plan to minimize the adverse effect by the spilt light from the roadway lighting.
        4,000원