        1.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the ELF-MF emissions from UCLs and to compare the ELF-MF emission levels of HVTLs and UCLs. In addition, this study proposes a method and management plan to investigate the effects of exposure to ELF-MF emissions from UCLs. The ELF-MF emissions from the 154 kV UCL were 15.4±24.4 (GM: 7.8)mG, while from the 345 kV line they were 6.0±2.4 (GM: 5.7)mG. Through the comparison between ELF-MF emissions of 154 kV UCL and HVTL, at about 20 m distance from an overhead line the emissions level is 4 mG, while from an underground line at about 10 m distance the emission level was recorded as less than 4 mG. Through comparing the ELF-MF emission amount of the UCL according to the burial method, it was found that the direct ELF-MF emission levels are 15.3±7.4 (GM: 13.9)mG at the direct point, in the conduit type 21.0±30.4 (GM: 10.8)mG, and in the buried form 8.5±12.3 (GM:5.1)mG. In this study, ELF-MF emissions were about 37.0% and 47.5% lower, respectively, compared with the direct power and conduit type. The correlation between ELF-MF emission (mG) and power load (A) was analyzed. The higher the power load, the higher the ELF-MF emission. The correlation between ELF-MF emission at the direct point and depth of the UCL was also analyzed, and it was found that as the depth of line burial increased, ELF-MF emissions decreased.
        4,000원
        2.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to determine whether crops and fruits absorb the naturally occurring asbestos (NOA). The concentration of asbestos in various crops and fruits grown in NOA areas was analyzed and background levels of asbestos in ambient air and soil samples were assessed. Actinolite/Tremolite asbestos were detected in all soil samples. Among 21 ambient air samples, 2 samples were recorded to contain 0.0005 f/cc (fiber per cubic centimeter) but no asbestos was detected in the other samples using transmission electron microscopy (TEM). However, no evidence suggesting that the crops and fruits could be contaminated by NOA was found in this study. The excess lifetime cancer risks (ELCRs) of ABS scenarios (agricultural activities) used in this study were calculated by using the Arithmetic (AM) and Geometric mean (GM) of ELCRs. The AM and GM of ELCRs estimated from digging soil and weeding activities did not exceed 1 × 10−4, which was defined as the general acceptable risk range for exposure. The results of this study would be informative to NOA managers and related policy makers to make plans to prevent unexpected exposure to asbestos to residents living in an NOA area.
        4,000원
        3.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated and reported the results of the distribution of in air particulate matter concentration inside school classrooms where children, who are known to be environmentally vulnerable, spend the most time after home. The objective of this study is to provide basic data for future studies related to indoor air quality in Yeongwol county and studies for improving school environment. The study investigated the levels of the concentration distribution of PM10 and PM2.5 in classrooms at 19 different elementary schools based in Yeongwol county from December 12 to 19, 2016. In the classrooms of the elementary schools in Yeongwol county, the pooled average concentration of PM10 and PM2.5 was 11.9 μg/m³ and 4.2 μg/m³, respectively. These concentration rates were lower than those of PM10 and PM2.5 surveyed in classrooms of elementary schools based in other regions of Korea. Further, they did not exceed 100 μg/m³, the PM10 guideline concentration provided by the School Health Act. The study results revealed that the winter concentrations of PM10 and PM2.5 in air inside classrooms of elementary schools based in Yeongwol county were influenced more by indoor sources such as indoor residents rather than outdoor sources.
        4,000원
        4.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated Extremely Low Frequency-Magnetic Fields (ELF-MF) exposure levels among housewives for a 24-Hour activity pattern to identify related factors for the exposures. To achieve the objective of the study, we surveyed ELF-MF levels using EMDEX II in a living environment from January to December 2016. We also made subjects write a Daily Activity Pattern in order to identify durations for staying and related information in the environment of exposures. Subjects showed that they spent the longest time in sleep and at home, at 487.5 minutes (KOSIS: 479.0 minutes) and 472.1 minutes (KOSIS: 428.0 minutes), respectively. Furthermore, the 24- hour time-weighted average (TWA) of 54 housewives was 1.24 ± 3.48 mG (GM: 0.52 mG). The ELF-MF exposure levels for all Multiuse Facilities were far below the recommended standards of EMF Guideline Korea and ICNIRP. Thus, these results will provide useful data for the determination of ELF-MF management and reduction methods in living environments.
        4,000원
        5.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate ELF-MF exposure levels of the elderly groups in their living environments using 24-hour personal measurement. In addition, EMF risk perception was investigated. Through evaluations of ELF-MF exposure levels in the proximity of the participants of 58 elderly groups, it was found that TWAam was 1.31 mG (TWAgm: 0.84). ELF-MF exposure levels of the elderly group that live in the proximity of a non-visible power line was high, but there were no statistically significant differences between the non-visible power line elderly group and visible power line elderly group. Moreover, there were no statistically significant differences in ELF-MF exposure according to gender, age, city classification, incomes, residence type, and size. The results showed that the perception of the ELF-MF was very low, as indicated by more than roughly 58.6% of the elderly surveyed saying that they did not know what ELF-MF was. In addition, there was no awareness among the group of how to avoid behavior of EMF from some electric equipment and facilities. Thus, these results will provide useful data for the determination of ELF-MF management and risk communication methods in the living environment for elderly people.
        4,000원
        6.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate ELF-MF exposure levels in infant living environmental spaces at daycare centers. To achieve the objective of the study, we surveyed ELF-MF levels using EMDEX II at daycare centers from October 2013 to October 2014. The ELF-MF level of 53 daycare centers in terms of arithmetic mean (AM) and geometric mean (GM) were 0.59 ± 0.76 mG and 0.33 mG, respectively. And the ELF-MF level of 260 daycare center classrooms was 0.50 ± 0.71 mG (GM: 0.28 mG). The exposure levels of ELF-MF for all daycare centers were far below the recommended standards cited in guidelines in Korea (833 mG) and international reference levels proposed by WHO or ICNIRP (2,000 mG). Furthermore, we discovered out that as distance increased, ELF-MF emission levels decreased significantly in all electrical instruments. Below the 2 mG ELF-MF levels when an electrical instrument moved away stage 1 (Grade). Thus, these results will provide useful data for the determination of ELF-MF management and reduction methods at infant daycare centers.
        4,000원
        7.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to assess RF-EMF exposure levels in indoor daycare centers in a Metropolitan city. RF-EMF measurements were collected and surveyed from 50 volunteer daycare centers in the Korea between October 2013 and October 2014. Through our research, it was found that the main exposure source for indoor daycare centers is the frequency bands for TV and Radio broadcasting (FM: 88.1~107.9 MHz), mobile phone (869~894 MHz, 1840~1870 MHz, 1885~2170 MHz), wireless LAN and home electronics, etc., including TRS, Wireless Data Communication. The RF-EMF exposure levels for all daycare centers were far below the recommended standards of EMF Guideline Korea and international reference levels proposed by ICNIRP (International Commission on Non-Ionizing Radiation Protection). However, in terms of long term health effects some uncertainty exists, and thus minimizing exposure may reduce this uncertainty. The data we collected will be useful data for determining RF-EMF management and risk communication at daycare centers.
        4,000원
        8.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Radon (222Rn) gas is a main source of ionizing radiation of natural origin. It typically moves up through the ground to the air above and into building or home through cracks and other holes in the foundation. Significantly, the Surgeon General has warned that radon is the second leading cause of lung cancer in the United States today. This survey covers the determination of indoor radon concentrations at home from 2013 to 2014 in some areas of Gangwondo, every three months (seasonal) during one year using an alpha-track detector. The results showed that the annual average concentration of indoor radon was 84.5 Bq/m3 (GM: 64.5 Bq/m3) at homes. Indoor radon level was the highest in winter and the lowest in summer. Geometric mean radon concentration in winter was 1.03~2.58 times higher than other seasons. The data obtained from this study provide a basis for the preparation of legal regulation and public health protection manuals in this area.
        4,000원
        9.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the level of ELF-MF emissions from underground cable lines near daycare centers in the metropolitan city of Seoul. We investigated 143 daycare centers from June to September of 2015. In addition, the rate of reduction of ELF-MF levels according to the distance from the line was calculated using simulations. The ELF-MF emission level of 143 daycare centers at boundary point was 1.37 ± 1.75 mG (GM: 0.75 mG) and at direct point was 11.14 ± 17.99 mG (GM:6.05 mG). ELF-MF levels at direct point were 8.13 (arithmetic mean) and 8.06 (geometric mean) times higher, respectively, than that at the boundary point. By analyzing the relationship between ELF-MF and electricity current (A) and operating depth (m), a significant correlation was found between ELF-MF and current (A) and depth (m), at 0.360 (p<0.01) and -0.303 (p<0.05), respectively. The results of the simulation showed that appropriate separation distances showing below 4 mG was 8m and 14m, adjusted mean current (A) and maximum current (A), respectively. The results of the study suggest that a plan should be implemented for the management of ELF-MF in High voltage power-line and Underground cable line areas, through a broad and detailed survey and risk communication.
        4,000원
        10.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated the concentrations of PM10 and CO2 in public transportation vehicles (express bus, train, KTX, and subway) reported by previous indoor air quality (IAQ) surveys carried out from 2005 to 2013 in Korea. The number of valid data for PM10 was 566 and for CO2 was 579, and all data were classified according to whether it was collected during rush-hour or non rush-hour. PM10 and CO2 concentrations in subway cabin during the rush-hour were 1.3 and 1.45 times higher, respectively, than those of non rush-hour (p<0.05) in terms of geometric mean value. PM10 and CO2 concentration of express bus and train during the rush-hour also were 1.23 times higher than those of non rush-hour with relatively weak correlations (p=0.246). Among all PM10 concentrations, 16.9% and 3.8% of PM10 concentrations exceeded the IAQ guidelines (200 μg/m3 for non-rush hour and 250 μg/m3 for rush-hour), respectively. In terms of CO2 concentrations, 10.5% and 3.0% of them exceeded the IAQ guidelines (2,500 ppm for non rush-hour and 3,000 ppm for rush-hour), respectively. As a result, concentrations of PM10 and CO2 were estimated to be dominantly influenced by the operation characteristics of public transportation, such as degree of congestion and type of vehicle. In order to improve the IAQ of public transportation vehicles, specific air purification and ventilation systems are needed, depending on the characteristics of public transportation vehicles.
        4,000원
        11.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to investigate the effect of ELF (Extremely Low Frequency) exposure on the health of elementary school students. A total of 103 students 12~13 years old were chosen for the study. The experimental group consisted of 56 students who went to school near an overhead powerline. The ELF exposure and environmental hazard factors were evaluated during a 24-hour exposure period. The body and dwelling characteristics of the students as well as disease occurrence related to the respiratory system and allergies were investigated through a questionnaire. The brain wave and electrocardiogram were also inspected. The exposure of the group exposed while at a school located near a powerline was 6.8 mG (p<0.01). Based on the questionnaire results, neither the body or dwelling characteristics of the two groups were affected by the ELF emitted from powerline. There was no significant difference between the two groups in relation to the rate of occurrence of respiratory diseases such as wheezing, asthma and bronchitis. Although brain waves of the group exposed to ELF were lower than that of the group not exposed to it in terms of absolute power of gamma and beta, there is no significant difference between the health status of the two groups. According to our study, school students who lived near a power line were exposed to higher ELF levels than those away from a power line. The two groups have significant differences inBrain wave and ECG, but this change doesn't mean there is a difference in health status. Finally, our study has a limitation in terms of the number of study subjects and the restricted area examined.
        4,000원
        12.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 사례연구는 갑상선 수술을 받은 환자의 연하장애 증상과 작업치료실에서 적용한 연하장애 재활 치료의 효과에 대해 알아보고자 하였다. 연구방법 : 갑상선 수술 후 연하장애를 호소하는 71세 여성을 대상으로 비디오 투시 연하검사(Videofluoroscopic Swallowing Study; VFSS)를 통한 기능적 연하장애 척도(Functional Dysphagia Scale; FDS)와 침습-흡인 척도(Penetration-Aspiration Scale; PAS)를 평가하였고, 미국언어청각협회 연하 척도(American Speech- Language-Hearing Association National Outcomes Measurements System; ASHA NOMS)로 환자의 삼킴 기능을 검사하였다. 치료 기간은 2014년 4월 18일부터 6월 5일까지이며, 총 27회 연하장애 재활치료를 받았다. 교정적 치료로 목 관절가동범위 및 근력 운동, 고개 들기 운동, 삼킴 기법, 성대폐쇄훈련, 후두상승훈련 -가성발성훈련, 전기 자극 치료를 받았고, 보상적 치료로 자세 기법, 음식 양과 속도 변경, 음식 농도 변경에 대한 치료를 받았다. 결과 : 치료 결과 비디오 투시 연하검사를 통한 기능적 연하장애 척도 점수가 42점에서 20점, 16점, 침습 -흡인 척도는 6단계에서 4단계, 2단계로 각각 감소하였다. 미국언어청각협회 연하 척도는 1단계에서 5 단계, 6단계로 상승하였다. 결론 : 본 연구 결과 연하장애 재활치료가 갑상선 수술 환자의 삼킴 기능에 긍정적인 영향을 미치는 것으 로 나타났다.
        4,300원
        13.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the characteristics of asbestos containing materials in public facilities in Korea. We investigated 201 public facilities between January and December in 2009. PACM were collected according to EPA AHERA rules, and analyzed using the US EPA method 600/R/116. The air samples from public facilities were analyzed by PCM. For the survey on ACM risk assessment, we used both the ASTM rules and Korea ACM risk assessment(developed by the Korea ministry of employment and labor). Public facilities showed that ceiling textiles contained chrysolite/amosite(2 and 25%) and cement flat boards contained chrysolite(5 and 26%). Also, gaskets contained chrysolite(3 and 95%) and Floor tile & carpet contained chrysolite(less than 1 and 6%). PCM analysis was performed on all air samples, and it was found that the concentration of fiber did not exceed the Korean guideline(0.01f/cc). In this study, it was found that according to the ASTM rule of asbestos material, 70 materials were “Abatement” grade and 344 materials were “Q&M” grade when assessed by ASTM B-line. Furthermore, based on the adjusted Korea ACM risk assessment 22 materials rated as were “Fair” and 390 materials were “Good”.
        4,200원
        14.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, ELF-MF levels of subway trains were measured to understand the status of the intensity of ELFMF. The measurement points for the train are selected in the center of each train compartment(pantagraph compartment, motor-driven compartment and the compartment that is not connected to any other electric equipment) using EMDEX II. ELF-MF levels of trains were measured from the starting to the terminal station in each lines(Seoul line 1-9, Incheon line 1, Incheon international airport line, Gyungui line, Bundang line, Gyeongchun line, Joongang line, Suin line). We found that the mean and range of ELF-MF levels in the DC power subway train are 2.4 and 0.1~125.9 mG, respectively, while the mean and range of ELF-MF levels in the AC power subway train are 10.4and 0.0~156.3 mG, respectively. Furthermore, the maximum ELF-MF level(156.3 mG) was lower than the reference level(ICNIRP 833 mG, 60Hz). The findings of this study in relation to the characteristics of ELF-MF for subway will be useful to derive the ELF-MF exposure coefficient from our living environment in a subsequent study.
        4,000원
        15.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An elementary school is a significant facility for educating and cultivating children and it is where they spend most of their days. The purpose of this study is to conduct an analysis on PM10 and TBC concentrations in 110 elementary schools in Suwon. We investigated 110 elementary schools from March 2011 to December in 2012. The mean concentration of PM10 and TBC were 51.3 ± 18.0 μg/m3(GM: 47.9 μg/m3) and 311.0 ± 125.3 CFU/m3 (GM:293.3 CFU/m3), respectively. All measurement concentrations did not exceed the Ministry of Education IAQ guidelines. Also, the concentrations of PM10 and TBC were not affected by various conditions such as Outdoor PM10, school construction year, class student number, temperature(oC) and humidity(%). The results of the study suggest that management of the IAQ plan in elementary schools should be implemented through Daily-Pattern and Activity-Pattern analysis for assessment of IAQ.
        4,000원
        16.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 작업치료사가 근무하는 전국 의료기관의 전자의무기록시스템(Electrical Medical Record; EMR) 도입 수준 및 임상 용어 사용 현황을 알아보고, 향후 작업치료 임상용어체계의 표준화를 위한 기 초자료로 활용하기 위하여 실시하였다. 연구방법 : 전국의 작업치료사들이 근무하는 121곳의 의료기관을 대상으로 작업치료 서비스에 대한 임상 용어 사용 현황을 설문조사하였다. EMR을 사용하지 않는 경우와 사용하는 경우로 나누어 분석하였으며, SPSS의 다중응답(multiple response) 모듈을 이용하여 빈도분석을 적용하였다. 결과 : 조사대상 총 121개 기관 중 EMR을 사용하는 기관은 102개, 84.3% 였다. 치료예문이 미리 입력 되어 있고 시행 내용을 불러오는 형식으로 예문 수정이 가능한 경우가 많았으며, 사용하는 작업치료 용 어가 수행중인 치료 영역을 포함하는가에 대한 질문에서 60.0%이상이 부족하다고 응답하였다. 작업치료 임상용어의 표준화 필요성에 대해서는 85.1%가 필요하다고 응답하였으며, 협회에서 공식적인 임상용어 표준안을 제시할 경우 74.5% 기관에서 적용의사가 있다고 응답하였다. 결론 : 본 연구를 바탕으로 국내 작업치료사의 직무와 국제의료행위분류, Current Procedural Terminology (CPT) 코드, Occupational Therapy Practice Framework (OTPF) 용어 등에 근거한 한국화된 작업치 료 임상용어 표준화 작업이 이루어져야 할 것이다.
        4,500원
        17.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Asbestos was a general term applied to certain fibrous minerals long popular for their heat-resistance, tensile strength, acoustic insulation and inexpensive price. Despite its many uses, asbestos is a hazardous material. Inhalation of asbestos fibers can cause serious health problems, such as lung cancer, asbestosis and mesothelioma. According to the compliance regulations for asbestos-related materials in Korea, all kindergartens have to be inspected for asbestos materials before April 2014. The purpose of this study is to investigate the distribution of asbestos containing materials in kindergartens in Gwangju, Korea. We investigated 93 kindergartens between January and May in 2014. Asbestos types and contents were analysed using the polarized light microscopy (PLM). Kindergartens facilities that featured ACM(Asbestos Containing Material) included ceiling textiles that contained chrysolite/amosite in amounts between 2 and 5% and gaskets that contained chrysolite in amounts between 15 and 35%. Also, wall cement flat boards contained chrysolite in amounts between 10 and 15%. In this study, risk assessment of asbestos material showed that all kindergarten materials were classified as Low grade when assessed by the Korea Ministry of Employment and Labor guideline method.
        4,000원
        18.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to analyze dust mite allergen and bacterial endotoxin concentrations in the subwaycabins. For this aim, we sampled dust using a vacuum cleaner on cabin seats of subway trains operating in threeSeoul Metro Lines from April to May in 2011. The concentration of dust mite allergen and endotoxin were1,137.51±806.26ng/g and 5,742.1(4.68)EU/g, respectively. While, the concentration of dust mite allergen washigher on cabin seats of subway trains in Line B(1,487.61±930.59ng/g) than on those of trains in Lines A andC(641.9±398.3 and 1,344.9±822.4ng/g). All measurements did not exceed the National Workshop Guidelineof 2,000ng/g. While, bacterial endotoxin concentration [GM (GSD)] was higher on cabin seats of subway trainsin Line A [12,373.21(4.97EU/g)] than on those of trains in Line B and C8,520.77(3.98) and 1,631.43(1.88)EU/g. Dust mite allergen concentrations were strongly influenced by the portion of underground (on the subway line)and endotoxin concentrations were significantly correlated with the number of passengers using the subway lines.Seats for seniors and the week showed relatively higher concentrations compared to seats for general passengers.But, no significant difference of dust mite allergen and endotoxin concentrations in the subway cabins was foundrelating to seat type (p=0.451, p=0.564). There was no correlation between the dust mite allergen levels andendotoxin levels in the subway cabins (p=0.439).
        4,000원
        19.
        2007.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        To investigate characterization of EMF(Electromagnetic Field) emission from VDT(Visual Display Terminal) in computer room, we were divided into 3 types of placement monitors which are 1) back side of monitor faced the ground(back view type), 2) arrangement of monitors was a line type(two sides type), and 3) disposition of monitors was s straight(horizontal line type). We also measured monitors classified types at the front, side and back by distance and evaluated by TCO(The Swedish Confederation of profession Employers) and MPR-2(Measure and Proof Radiation Board) guide line. Magnetic field emission level by the type of VDT, it was indicated that MF(Magnetic Field) level was below the backgrounds level when CRT moved away about 70~90cm, LCD moved away about 40~50cm. We evaluated MF emission level by the number of VDT, it did not show any relationship. Finally, estimated MF emission level by the placement of VDT, it was showed the MF level less than the background level, when VDT moved away 40~50cm in all dispositions with exception of 2 sites. Background level of case was higher than emitted from VDT, so that did not effect on MF level by distance. However, we find out that as distance increased, MF emission level decreased significantly in all cases. We measured MF emission level of one monitor and others (back and forth) monitor in line type. Below the background level when one monitor type moved away 70cm, others monitor type moved away 40cm. However, other monitor types affected MF level which is located back monitor. The data demonstrate that avoiding excessive MF exposure from VDT using computer room, to have a space between user and VDT at least 50㎝.
        4,000원