검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 17

        4.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An electric steam boiler equipped with a condensate recovery system, which stores the condensate generated after using steam in steam washers, steam cookers, steam irons, and steam cleaners in a condensate tank and supplies compressed air to the condensate tank so that the condensate is recovered to the boiler by the pressure of the compressed air, was studied. In the results of this study, the heat energy balance between the quantity of the heat generated by the non-metallic surface heating element and the quantity of the heat absorbed by the water was good in a range of ±5%. In addition, the heat transfer rate increased in proportion to the electric power of the surface heating element heater, the waste heat energy was normally recovered by the recovery of the condensate of the steam boiler equipped with the high compression waste heat recovery system, and the recovery rate of the waste heat exhibited 23%.
        4,000원
        5.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인위적인 산성스트레스가 담수산 소백옆새우(Gammarus sobaegensis Ueno)에 미치는 영향을 정체성 수조건 하에서 급, 만성 생태독성실험을 통해 알아보았다. 급성독성 실험 시 pH 3 대역에서의 반수치사시간(LT50)은 평균 0.271(±0.146)day로 개체의 크기 또는 먹이의 유무 그리고 주변 환경에 대한 적응능력에 관계없이 일정한 모습을 나타내고 있었다. pH4.0대역에서의 LT50은 0.812(±0.
        4,000원
        6.
        2000.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 단각목의 일종인 소백옆새우(G. sobuegensis)를 대상으로 인공수로 하에서 pH 변화를 유도시킬 때 발생되는 개체의 표류행동에 대한 이동특성을 알아보았다. 본 종은 낮은 pH수준의 산성스트레스에서 회피행동이 현저하게 증가한다는 것을 알 수 있었으며, 또한 산성도에 따른 내성범위는 개체의 성숙도 즉 중소형보다 대형개체가 보다 민감하게 반응하는 것을 확인할 수 있었다. 특히 산성 스트레스에 의한 반응이 대형개체에 비해 소형과 중형개체에
        4,000원
        7.
        1998.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 ℃ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.
        4,200원
        9.
        1994.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This work studies for boiling and condensation heat transfer performance of trapezoidally shaped integral-fin tubes having fin densities from 748fpm to 1654fpm. For comparison, tests are made using a plain tube having the same inside and outside diameter as that of the root of fins of finned tubes. Hahne's theoretical model and Webb's theoretical model are used to predict the R-11 boiling heat transfer coefficient and condensing heat transfer coefficient respectively for plain tube and all integral-fin tubes. Experiments are carried out using R-11 as working fluid. This work is limited to film-wise condensation and pool boiling on the outside surface of plain tube and 4 low integral-fin tubes. In case of condensation, the refrigerant condenses at saturation state of 32℃ on the outside tube surface cooled by coolant and in case of boiling. the refrigerant evaporates at saturation state of 1bar on the outside tube surface. The amount of non-con-densable gases in the test loop is reduced to a negligible value by repeated purging. The actual boiling and condensing processes occur on the outside tube surfaces. Hence the nature of this surface geometry affects the heat transfer performances of condenser and evaporator in refrigerating system. The condensation heat transfer coefficient of integral-fin tube is enhanced by both extended tube surface area and surface tension. The ratio of the condensation heat transfer coefficients of finned to plain tubes is greater than that of surface area of finned to plain tubes, while ratio of the boiling heat transfer coefficient of finned to plain tubes shows reverse result. As a result, low integral-fin tube can be used in condenser more effectively than used in evaporator.
        4,300원
        17.
        1974.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        3,000원