The connection of the steel structure serves to transmit external forces to the main components. The same is true for the behavior of modular systems composed mainly of steel or composite members. In this study, the joint performance of the composite and steel modules proposed was evaluated. The analytical models of the two joint types were constructed and were subjected to cyclic loading to assess the safety and the energy dissipation capacity of the joint types. The analysis results of the joints showed that the joints of the modular systems remain stable when the joint rotation reached the seismic performance limit state of the 0.02 rad required for steel intermediate moment frame. It was also observed that the joint of the composite modular system showed higher energy dissipation capacity compared with the steel modular system.
모듈러 시스템은 하중저항 방식에 따라 개방형 모듈러 및 폐쇄형 모듈러 분류가 된다. 그 중 개방형 모듈러는 폐쇄형 단면을 갖고 있어 부재간의 접합 및 모듈간의 접합을 하는데 제약이 있다. 이에 Choi et al.(2017)은 절골형 단면 안에 콘크리트를 채운 합성 모듈러 시스템을 제안하였다. 하지만 모듈간 접합을 강접으로 가정하여 접합부 거동에 의해 구조물 전체에 미치는 영향을 파악하지 못하였다. 본 연구에서는 유한요소해석을 하여 제안된 모듈러의 접합부 강성을 산정하였다. 성능 검증을 위해 FEMA 440의 선형화방법을 사용하여 접합부 강성 유, 무에 따른 구조물의 내진성능을 파악하였다. 해석결과에 따르면 접합부 강성을 고려한 모델의 보유 내력 및 층간변위비가 접합부 강성을 고려하지 않은 모델에 비해 현저하게 감소하는 것으로 나타났다. 이를 토대로 접합부의 강성이 전체 구조물 거동에 영향을 미치는 것으로 판단된다.
모듈러 시스템은 하중저항 방식에 따라 개방형 모듈러 및 폐쇄형 모듈러 분류가 된다. 그 중 개방형 모듈러는 폐쇄형 단면을 갖고 있어 부재간의 접합 및 모듈간의 접합을 하는데 제약이 있다. 이에 Choi et al.(2017)은 절골형 단면 안에 콘크리트를 채운 합성 모듈러 시스템을 제안하였다. 하지만 모듈간 접합을 강접으로 가정하여 접합부 거동에 의해 구조물 전체에 미치는 영향을 파악하지 못하였다. 본 연구에서는 유한요소해석을 하여 제안된 모듈러의 접합부 강성을 산정하였다. 성능 검증을 위해 FEMA 440의 선형화방법을 사용하여 접합부 강성 유, 무에 따른 구조물의 내진성능을 파악하였다. 해석결과에 따르면 접합부 강성을 고려한 모델의 보유 내력 및 층간변위비가 접합부 강성을 고려하지 않은 모델에 비해 현저하게 감소하는 것으로 나타났다. 이를 토대로 접합부의 강성이 전체 구조물 거동에 영향을 미치는 것으로 판단된다.
By producing pre-engineered modular system in the factory, It is enable to expedite construction and can be distinguished from two types by the method resisting load. One is the open-sided modular system composed of beams and columns. The other is enclosed modular system composed of panels and studs. Of the modular systems, the open-sided modular system buildings the connection between modules are difficult due to closed member sections, and the overall strength is reduced as a result of local buckling. In this study, in order to solve these problems, a modular system with folded steel members filled with concrete are proposed. The capacity spectrum method presented in ATC 40 is used for seismic performance assessment of the proposed model structure and the structure with conventional steel members. The analysis results show that at the performance point of each model the number and rotation of plastic hinge formed in the proposed modular system are smaller than those in the conventional system. Based on this observation it is concluded that the proposed system with composite sections has superior seismic capacity compared with conventional system.
Based on the study of seismic retrofit of buildings using damper of apartment buildings, it was found that using genetic algorithm is efficient for seismic retrofit compare to existing way of retrofit. Therefore using genetic is recommended when seismic retrofit applied.