        검색결과 52

        41.
        2019.04 서비스 종료(열람 제한)
        Voided Slab is a very efficient system that can reduce weight and its use has increased. In this paper, Shear performance of voided slab 3 type(rc slab, ball slab, ball slab with water) with improved damping performance was evaluated. As a result of the test, the shear performance was not much different from the existing RC slab.
        42.
        2018.10 서비스 종료(열람 제한)
        In this study, the effect on seismic performance of Binding Column Method(BCM) system was empirically evaluated. Four column models that were confined by different forces and one rare column model as a control were manufactured for cyclic loading test. As a result, in the column retrofitted with BCM, the ultimate displacement and load were increased about 2.5 and 2.0 times. Also, the energy-dissipating capacity of the retrofitted model was improved, compared to a rare column model.
        43.
        2018.04 서비스 종료(열람 제한)
        Recently, because of the increased needs for isolation device structure, a lot of buildings equipped with isolation systems are designed. In this paper, we provide the information about the seismic isolation effects due to the stiffness variation of isolation devices due to the manufacturing errors for middle layer seismic isolation.
        44.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        중공슬래브는 휨 성능에 영향을 미치지 않는 부분의 콘크리트 단면을 삭제하고 중공재로 치환함으로써 중공재 부피만큼 콘크리트가 줄어들어 자중 감소효과를 가져오는 장점이 있다. 또한, 콘크리트의 물량절감뿐 아니라 친환경적 측면에서 이산화탄소의 배출도 저감할 수 있어 효과적이다. 하지만, 중공재로 치환한 부분의 지압강도가 명확하지 현장 적용 시에 여러 가지 문제점이 발생한다. 이에 본 연구에서는 중공재가 포함된 중공슬래브를 제작하여 각 타입별(트럭 하중 적용 시, 동바리 하중 적용 시 및 잭 서포트 하중 적용 시)로 국부지압강도 실험을 수행하여 중공슬래브 국부 지압강도의 안전성을 평가하고자 한다. 트럭하중 적용 시, 동바리 하중 적용 시 및 잭 서포트 하중 적용 시의 실험결과 중공재 연결부위 및 중공재 상부의 지압강도는 모든 실험체에서 허용 하중 이상을 보유한 것으로 나타났다. 또한 데크 적용 유무에 따른 실험결과도 모두 허용 하중을 초과하여 안정성을 확보하는 것으로 나타났다.
        45.
        2017.09 서비스 종료(열람 제한)
        The purpose of this study is to corroborate hydration and porosity of cement paste by the low water-cement ratio specimen. The test results show that calcium hydroxide was increased as the moisture was supplied from the outside and the porosity was lowered with a rapid manner.
        46.
        2017.09 서비스 종료(열람 제한)
        Nonlinear dynamic analysis of Non-seismic Designed subway station was verified with Channel Beam Damper system which was developed in former research. As a result of nonlinear dynamic analysis, column and beam are on LS(Life Safety) level by retrofitting with Channel Beam Damper system. The effect of Channel Beam Damper System was confirmed.
        47.
        2017.09 서비스 종료(열람 제한)
        This study investigates overseas and domestic practical applications of systems that combine seismic isolating characteristics and vertical vibration-proof function for releasing annoying vibration from road traffic, subways, and trains. This paper proposes the configuration of vertical vibration -proof and seismic isolating systems based on the evaluation of their effectiveness.
        48.
        2017.04 서비스 종료(열람 제한)
        Recently, because of the increased needs for damped structure, a lot of buildings equipped with damping systems are designed. In this research, in order to reduce the base shear down to the desired, additional damping ratio of damping device for each period was determined with seismic response spectrum
        49.
        2017.04 서비스 종료(열람 제한)
        Anchors used in concrete structures are classified into cast-in-place anchors and post-installed anchors. At post-installed anchors, the effective embedment depth, measured from the concrete surface to the deepest point, is an important variable to grasp the performance of anchors. Because effective embedment depth is depth to transmit force to the concrete. In this study, we conducted pull-out test of M12 and M16 post-installed anchors, evaluated the performance of anchors.
        50.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Recently, because of the increased needs for damped structure, a lot of buildings equipped with damping systems are designed. In this research, in order to reduce the base shear down to the desired, additional damping ratio of damping device for each period was determined with seismic response spectrum.
        51.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Anchors used in concrete structures are classified into cast-in-place anchors and post-installed anchors. At post-installed anchors, the effective embedment depth, measured from the concrete surface to the deepest point, is an important variable to grasp the performance of anchors. Because effective embedment depth is depth to transmit force to the concrete. In this study, we conducted pull-out test of M12 and M16 post-installed anchors, evaluated the performance of anchors.