A study on the possibility of recycling by solidification using tailings from abandoned metal mine were studied. The study was carried out on testing compressive strength of concrete made by different ratio of various mine tailing, chemical speciation of Cd, Cu, Pb and Zn in the tailing by sequential extraction procedure and SPLP leaching test. Mixing of mine tailings with cement or asphalt and aging of mortar gave strong influence on compressive strength of concrete. Marshal's stability of asphalt with tailing waste were higher of 98.0~101.0% than not added one. Therefore it was recommended to use of the tailings to low the infiltlation of the water to protect the bank in the abandoned mine region. Total metals in concrete and asphalt with tailing waste were lower than that of tailing waste. The amount of adsorbed fraction and carbonate fraction which were labile in the aquatic environment were very lower in the concrete and asphalt specimen than mine tailing waste.Leachabilityof studied metals are under the waste management standard.
흉부 디지털 단층영상합성장치는 기존 DR의 낮은 깊이 해상도, CT의 높은 피폭선량 문제를 해결할 수 있는 획기적인 영상장치로 대두되고 있다. 그러나 제한된 스캔 각도로 인해 프로젝션이 X 선 소스 동작 방 향으로 흉부를 완전히 포함 할 수 없어 재구성 된 슬라이스의 위, 아래 방향 경계를 따라 강도의 불연속성 이 발생하게 되는데 이러한 현상을 잘림 아티팩트 (Truncation artifact)라고 한다. 이 연구의 목적은 가중 정규화 접근법을 사용하여 잘림 아티팩트를 줄이고 리스템에서 개발한 프로토 타입 흉부 디지털 단층영상합 성장치 시스템에 대한 이 접근법의 성능을 평가하는 것이다. 이 시스템의 source-to-image distance는 1100 m m 이고 X 선원의 회전 중심은 검출기 표면에서 100mm 위로 설정되었다. LUNGMAN 팬텀을 사용하여 ± 20 °의 투영 뷰를 1 ° 간격으로 41장을 얻은 후, filtered back projection 알고리즘으로 재구성했다. 정량적 평가를 위하여 시뮬레이션을 이용하여 기준영상을 재구성 후 peak signal to noise ratio와 structure similarity ind ex 값을 평가하였으며 실제 실험 데이터를 이용하여 mean value of specific direction 값을 평가하였다. 시뮬 레이션 결과로 아티팩트 보정 전 일반적인 filtered back projection 알고리즘으로 재구성 한 영상과 비교하여 peak signal to noise ratio값과 structure similarity index값 모두 각각 증가하였으며, 실제 실험 재구성 영상의 mean value of specific direction 결과는 아티팩트의 영향이 감소됨을 확인할 수 있었다. 결론적으로, 가중 정규화 방법은 잘림 아티팩트를 줄임으로써 진단의 어려움을 발생시키는 가능성을 개선시킬 수 있는 방법으로 사료된다.
Hepatocytes derived from human embryonic stem cells (hESCs) may be a useful source for the treatment of diseased or injured liver. However, a low survival rate of grafted hepatocytes and immune rejection are still major obstacles to be overcome. We previously showed that secreted proteins (secretome) from hESC-derived hepatocytes had a potential therapeutic power in the tissue repair of injured liver without cell transplantation. The purpose of the present study was to discover key protein(s) in the secretome of hESC-derived hepatocytes using proteomic analysis and to study the tissue repair mechanism which may be operated by the secretomes. Purified indocyanine green+ hepatocytes derived from hESCs displayed multiple hepatic features, including expression of hepatic genes, production of albumin, and glycogen accumulation. The nano-LC/ESI-QTOF-MS analysis identified 365 proteins in the secretome of hESC-derived hepatocytes and the protein functional network analysis was conducted using the MetaCore TM from GeneGO. In addition, 20 tissue regeneration-related transcription factors (TFs) were extrapolated through further proteomic analysis. After intraperitoneal injection, the secretome significantly promoted the liver regeneration in a mouse model of acute liver injury. Protein functional network analysis on the secretome-induced regenerating liver confirmed 20 transcription factors (TFs) which were identified in the ICGhigh cells. The upreguation of these tissue repair-related TFs were validated by qPCR and western blotting on the regenerating liver tissues. These results demonstrate that application of the secretome analysis in combination with the protein functional network mapping would provide a reliable tool to discover new tissue-regenerating proteins as well as to expand our knowledge of the mechanisms of tissue regeneration.
본 연구의 목적은 CR(Computed Radiography)과 DR(Digital Radiography)장비의 각 Detector를 통해 획 득된 영상의 화질을 비교 분석하기 위한 것이다. CR(AGFA MD 4.0 General plate, JAPAN)과 DR(HOLOGIC nDirect Ray, USA)에 대한 영상평가의 주요인자인 MTF(Modulation transfer function), NPS(Noise power spectrum), Photon fluence, DQE(Detective quantum efficiency)를 정량적인 값으로 도출 하여 비교한 결과 CR이 DR보다 우수하게 나타났다. 본 연구의 결과는 CR과 DR장비의 Image quality를 정량적으로 평가할 수 있을 뿐만 아니라 이 장비들을 유지, 보수하는데도 도움이 될 것으로 사료된다.
본 연구의 목적은 ROC를 이용하여 일반 촬영기기에 따른 영상의 질을 평가해보고자 함이다. 본 연구 의 수행을 위하여 CR(Computed Radiography)과 DDR(Direct Digital Radiography)을 사용하였으며 피사체 로 흉부 팬텀을 사용하였다. 각 기기에서 영상을 획득한 후 ROC평가를 이용하여 영상의 질 및 기기의 특성을 평가하였다. 조사 조건으로 관전압 120kVp와 관전류량 3.2 mAs를 이용하였고 SID(Source to Image Distance)는 180㎝로 설정하였다. 팬텀의 심장, 폐야, 흉추부위에 병소를 표현하였으며 각 장비에 서 획득한 영상의 질 및 기기의 특성을 파악하기 위하여 방사선학 전공자 29명을 대상으로 ROC평가를 실시하였다. ROC 평가 결과 DDR의 TPF(true positive fraction)는 0.552, FPF(false positive fraction)는 0.474, CR의 TPF는 0.629, FPF는 0.405로 나타났다. 본 연구 결과 CR의 영상이 DDR의 영상보다 더 나 은 영상의 질을 나타내는 것을 확인하였다. 영상의 질의 확연한 차이의 원인은 DDR의 경우 enhance board의 미 삽입으로 인한 영상 후처리의 미수행이라고 사료된다. 추후 DDR의 enhance board의 삽입 후 영상의 후처리가 가미된 DDR영상의 질에 대한 연구가 필요하며 본 연구의 결과로 인하여 영상의 후처 리가 임상의 판독에 있어서 매우 중요한 요소임을 확인할 수 있었다.