This study reports on the influenceof N-butyl-N-methylpyrrolidinium tetrafluoroborat (PYR14BF4) ionic liquid additive on the conducting and interfacial properties of organic solvent based electrolytes against a carbon electrode. We used the mixture of ethylene carbonate/dimethoxyethane (1:1) as an organic solvent electrolyte and tetraethylammo-nium tetrafluoroborate(TEABF4) as a common salt. Using the PYR14BF ionic liquid as additive produced higher ionic conductivity in the electrolyte and lower interface resis-tance between carbon and electrolyte, resulting in improved capacitance. The chemical and electrochemical stability of the electrolyte was measured by ionic conductivity me-ter and linear sweep voltammetry. The electrochemical analysis between electrolyte and carbon electrode was examined by cyclic voltammetry and electrochemical impedance spectroscopy.
Due to their morphology, electrochemical stability, and function as a conducting carbon matrix, graphene nanosheets (GNS) have been studied for their potential roles in improving the performance of sulfur cathodes. In this study, a GNS/sulfur (GNS/S) composite was prepared using the infiltration method with organic solvent. The structure, morphology and crystallinity of the composites were examined using scanning electron microscopy, transmission electron microscopy, and X-ray diffraction. The electrochemical properties were also characterized using cyclic voltammetry (CV). The CV data revealed that the GNS/S composites exhibited enhanced specific-current density and ~10% higher capacity, in comparison with the S-containing, activated-carbon samples. The composite electrode also showed better cycling performance for multiple charge/discharge cycles. The improvement in the capacity and cycling stability of the GNS/S composite electrode is probably related to the fact that the graphene in the composite improves conductivity and that the graphene is well dispersed in the composites.
일본 고베지진후 구조물 수직방향 내진거동의 중요성은 잘 인식되었으나 대부분의 내진설계규준에서는 지반조건을 규정하지 않아 수직방향 구조물 내진해석시 대개 토질과 기초조건을 무시하고 수행하였다 이 논문에서는 연약지반이 Taft 지진과 El Centro 지진의 수직방향 지진하중을 받는 구조물의 수직방향 반응에 미치는 영향을 알아보기 위해 기초크기, 기초 및 지반깊이 , 기초근입깊이 및 말뚝기초가 수직방향 내진반응스펙트럼에 미치는 영향에 대해 연구하였는데 지반은 UBC-97에서 분류한 Sa. Sc. SE를 기초크기는 중 대형 기초를. 기초 및 지반깊이는 30m 와 60m를 기초근입깊이를 0m와 15m를 고려하였으며 연약지반에 설치한 말뚝은 기성제 콘크리트 선단지지말뚝을 고려하였다 연구결과에 의하면 기초크기는 구조물의 수직방향 내진반응에 별 영향이 없지만 지반깊이는 수평방향 내진해석에서처럼 기초 및 60m까지 고려해야 하며 연약지반위에 설치된 묻힌기초와 얕은 말뚝기초는 구조물의 수직방향 내진거동을 크기 증폭시켰다.
In this study, We developed the framework for the vehicle damage estimation according to flood disaster. Especially, we constructed the vehicle inventory DB using dasymetric mapping, and suggested methods for the vehicle classification, asset valuation, depth-damage curve.
Among the various disasters caused by climate change, flooding has account for more than 70% for domestic disaster. This study develops an integrated system that be able to express and spread the disaster information, which can corresponds to the flooding. DRiMSS developed in this study consists of four modules, including RASS, LeVAS, FROK, and FRIENDs. DRiMSS is applied to Sungseo industrial complex in Daegu, and it is confirmed that DRiMSS can produce, express, and spread various disaster information according to the progress of the flooding.
제방, 댐, 교량, 도로 등 주요 시설물은 일상적인 사회·산업적 활동을 지원하기 위한 수단으로서 뿐만 아니라, 재난발생 시 인적·물적 자산을 보호해 준다는 점에서 매우 중요한 의미를 가진다. 그러나 시설물의 중요성에도 불구하고 이들을 적극적으로 활용하고 있는 재난관리시스템이 아직 개발되어 있지 않으며, 정작 재난이 발생할 때는 시설물 보호 및 활용을 배제한 대응이 이루어져 2차·3차적인 피해를 발생시키고 있다. 더욱이, 2014년 한국에서 발생한 세월호 유람선 침몰사건에서 제기된 여러 가지 이슈들, 예를 들어, 재난 발생 시 적절한 대응방안 제시 및 이와 관련된 즉각적인(Golden time) 의사결정, 신속한 현장 파악 및 보고, 구조·복구를 위한 자원(Resources) 관리 및 동원, 통합적 콘트롤 기능 등의 이슈들이 SOC시설물 재난관리 상황에서도 제기될 수 있는 바, 이를 적절히 해결하기 위한 방안이 필요하다.
따라서 본 논문에서는 홍수 등 재난 영향흐름(Impact Flow)에 기반을 둔 SOC시설물 위험도 평가체계를 제안하여 상기 이슈들에 대한 해결방안을 논의하고자 한다. 이를 위해 Hazus-MH, DIMSuS 등 최근 주요선진국들의 관련 기술 및 연구에 대한 포괄적인 문헌분석을 실시하였으며, System Dynamics 시뮬레이션 모델 구축을 통해 알고리즘 검증 및 TB 적용성을 검토하였다.
본 연구를 통해 제공될 SOC시설물에 대한 통합적 위험도 관리 기능은 SOC시설물의 안전 및 재해예방 관련 정책결정자와 관리자들에게 합리적인 의사결정수단을 제공하고 궁극적으로 대상 SOC시설물의 안전도를 향상시키는데 기여할 수 있을 것으로 판단된다.
Through the analysis of load behavior for two load cases, the fixing equipment developed shows higher limit load than maximum load data sensed in site experiments, which proves that the suggested fixing equipment have higher safety.
Through the analysis of load behavior for two fixing equipments, the suggested fixing equipment shows higher limit load than an existing fixing equipment, which proves that the suggested fixing equipment have higher safety.
It has becoming issue of damage in finishing materials of the exterior and interior when have to the transportation and lifting. So the purpose of this study is analyze for correlation of load on connecting part of unit modular when transporting unit modular by vehicle
Based on the study of development of motor-driven electric tool, it was found that the use of the mechanism developed was effective to bolt unit modules. On the other hand, an additional study is required such as torque of the tool.