검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2010.07 KCI 등재 서비스 종료(열람 제한)
        The study is about variations in Carbonyl compounds concentration within apartment buildings according to pre-residence and residence. We consecutively investigated indoor air pollutants in 120 households in 6 cities at pre-residence and residence. Carbonyl compounds were collected using the 2,4-DNPH cartridge and were analyzed using HPLC. The carbonyls concentration of indoor air in the new apartments before occupation measured formadlehyde(76.0㎍/㎥), acetone(85.9㎛/㎥), acetaldehyde(13.8㎍/㎥). The carbonyls concentration of indoor air in the new apartments after occupation measured formadlehyde(233.1㎍/㎥), acetone(128.9㎍/㎥), acetaldehyde(29.8㎍/㎥), respectively. As a result, the mean concentration of carbonyl compounds within the pre-occupancy stage was lower than those of residence.
        2.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 ug/m3 and 468.38 ug/m3, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 ug/m3 and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 ug/m3) > m,p-Xylene(163.67 ug/m3) > Ethylbenzene(80.70 ug/m3)>o-XYlene (67.04ug/m3). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 ug/m3) > m.p-Xylene(121.79 ug/m3) > Ethylbenzene(53.92 ug/m3)>O-Xylene(24.94 ug/m3). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.