검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        1.
        2023.11 구독 인증기관·개인회원 무료
        This study investigates the behavior of bentonite, used as a buffer material in deep geological disposal systems, in the context of pore morphology under the influence of field-collected groundwater conditions. The bentonite was processed into block form using cold isostatic press (CIP) and subsequently analyzed for its pore morphology in situ using synchrotron X-ray computed tomography (CT) within the field-collected groundwater environment. Bentonite buffers play a critical role in deep geological disposal systems by preventing contact between disposal containers and groundwater. Bentonite typically exhibits swelling upon contact with water, forming few layers of water molecules between its structural layers. However, the presence of ions such as K+ and Cl- can lead to a sharp reduction in swelling pressure. Loss of swelling pressure could negatively impact the integrity of future deep geological disposal systems, making its assessment crucial. This study involves processing various types of bentonite, including natural Na-type bentonite, into block forms and subjecting them to exposure in both deionized water and field-collected groundwater conditions. Internal pore morphology changes were measured using Xray CT technology.
        4.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ODA finance in the water sector has decreased after reaching a peak in 2012 although total ODA commitments have steadily increased according to OECD DAC data. However, climate finance in the water sector has increased so much since 2013 according to 7 MDB Joint report on Climate Finance. Water, especially, in climate change is the main issue for adaptation, and the total finance in the water sector reached 50% of the international public adaptation finance in 2016. However, the procedures for approval and the requirements of the proposals for climate funds are different from those for development finance. Notwithstanding the changes in money flows in the water sector, most korean engineering consulting firms in the water infrastructure area are not ready to win the funds relating to climate change. Therefore, It is important to understand a variety of sources of climate funds, characteristics, funding scale on each purpose and procedures for approval. Korean government needs to provide the firms the opportunities to buildup experiences by getting involved in climate adaptation projects with the financial support for developing PPFs, concept notes, and proposals.
        4,600원
        5.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.
        4,000원
        12.
        2021.08 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        The dependencies of the chemical element abundances in stellar atmospheres with respect to solar abundances on the second ionization potentials of the same elements were investigated using the published stellar abundance patterns for 1,149 G and K giants in the Local Region of the Galaxy. The correlations between the relative abundances of chemical elements and their second ionization potentials were calculated for groups of stars with effective temperatures between 3,764 and 7,725 K. Correlations were identified for chemical elements with second ionization potentials of 12.5 eV to 20 eV and for elements with second ionization potentials higher than 20 eV. For the first group of elements, the correlation coefficients were positive for stars with effective temperatures lower than 5,300 K and negative for stars with effective temperatures from 5,300 K to 7,725 K. The results of this study and the comparison with earlier results for hotter stars confirm the variations in these correlations with the effective temperature. A possible explanation for the observed effects is the accretion of hydrogen and helium atoms from the interstellar medium.
        13.
        2017.09 KCI 등재 서비스 종료(열람 제한)
        In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small (0.2-0.5℃). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was 0.5-0.8℃ (Max. 1.6-2.1℃). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of 0.9-1.7℃. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of 1.5℃ lower temperature in the daytime and 0.7℃ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was 0.8-1.0℃, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean 0.9-1.3℃ (Max. 2.0-3.9℃) lower in the daytime than for the residential and apartment locations and mean 0.4-1.0℃ (Max. 1.3-3.1℃) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean 1.0-1.6℃ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.