        81.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents experimental studies aiming at evaluation of structural behaviors of RC (Reinforced Concrete) beams externally strengthened with taper ended CFRPs(Carbon Fiber Reinforced Polymers). Experiments are performed with RC beams having different numbers of CFRP layers and length of each layer. The beams are subjected to four point-bending with simply supported condition. Test results of taper ended CFRPs and non-tapered CFRPs are compared and the better strengthening effect is observed from tapered ended CFRPs.
        4,000원
        82.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The researches related to active control systems utilizing superelastic shape memory alloys (SMA) have been recently conducted to reduce critical damage due to lateral deformation after severe earthquakes. Although Superelastic SMAs undergo considerable inelastic deformation, they can return to original conditions without heat treatment only after stress removal. We can expect the mitigation of residual deformation owing to inherent recentering characteristics when these smart materials are installed at the part where large deformation is likely to occur. Therefore, the primary purpose of this research is to develop concentrically braced frames (CBFs) with superelastic SMA bracing systems and to evaluate the seismic performance of such frame structures. In order to investigate the inter-story drift response of CBF structures, 3- and 6-story buildings were design according to current design specifications, and then nonlinear time-history analyses were performed on numerical 2D frame models. Based on the numerical analysis results, it can be comparatively verified that the CBFs with superelastic SMA bracing systems have more structural advantages in terms of energy dissipation and recentering behavior than those with conventional steel bracing systems.
        4,300원
        84.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        형상기억합금의 복원력 및 복원량은 열 하중 및 기계적 하중으로 인한 마르텐사이트 상에서 오스테나이트 상으로의 상 변이에 의한 상변형률 발생에 기인한다. 복원력 및 복원량은 초기 형상 및 하중 부여 방식에 따라 차이가 발생하는데 적절 한 설계 전략없이 상변형률에만 의지한 경우 큰 복원력은 발생할 수 있어도 큰 복원량을 기대하기는 어렵다. 이는 형상기 억합금의 큰 복원력과 작은 복원량 간의 비대칭성에 기인하며 형상기억합금의 효율적인 이용에 걸림돌이 된다. 본 연구에 서는 형상기억합금의 상변이로 발생하는 복원량을 극대화하는 방안으로 형상기억합금 선이 이중으로 감겨있는 이중 나선 구조 형상기억합금 스프링을 제안한다. 그리고 열 하중에 의해 발생하는 복원량을 예측하고 단일 나선 구조 형상기억합금 스프링과 비교 분석하여 이중 나선 구조 형상기억합금 스프링이 단일 나선 구조 형상기억합금 스프링보다 성능 비대칭성 을 보다 완화시킬 뿐만 아니라 복원력 대비보다 큰 복원량을 가짐을 보였다.
        4,000원
        85.
        2012.04 구독 인증기관·개인회원 무료
        In this paper, we present the results of experimental investigation pertaining to the structural behavior of Tee joint connection composed of pultruded I-shape FRP members. In this study, we focus on the evaluation of load carrying capacity of Tee joint which appeared frequently to fabricate framed structure composed of pultruded FRP members. Through the experimental investigation moment-rotation relationship is found and the result is used to estimate the rotaion stiffness.
        86.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물 내 설치된 파이프시스템은 주로 내부구성원들의 인간생활에 근간이 되는 기반시설로서 현대 도시생활의 생명선과 같은 역할을 한다. 이들 구조물 내 파이프시스템이 만약 지진발생에 의하여 손상될 경우 1차적으로 구조물 내 기능성이 저하되고 구조물 내 많은 정신적, 물질적 피해가 발생할 수 있다. 실제 내진공학에서 지진발생에 따른 비구조재요소의 거동은 크게 중요하게 고려되지 않으나 인적 및 물적 피해와 매우 밀접하게 연관되는 가스 혹은 수계파이프시스템에 대한 비구조적 요소의 거동예측 및 성능평가 연구는 보다 효과적인 구조물 유지관리를 위하여 그 필요성이 크다고 판단된다. 본 연구는 현재 일반적으로 널리 시공되어져 있는 노후 철근콘크리트 빌딩구조물 내 설치된 가스 혹은 수계파이프시스템에 대하여 실제 지진발생이 예측되는 거동을 살펴보고 이들 거동에 따른 성능평가 및 현 설계기준에 대한 검토도 병행하여 수행하고자 한다. 이를 위하여 본 연구에서는 해석적으로 발생 가능한 총 10회의 지진파에 대하여 현재 실제 건물 내 기설치된 수계파이프시스템 모델링 및 해석을 통하여 그 결과를 검증, 평가하였으며 부가적으로 실제 발생 가능한 파괴유형 분석을 통하여 현 설치된 수계파이프시스템의 설계에 대한 적절한 내진보강방법에 대하여도 제안하고자 한다.
        4,000원
        88.
        2011.04 구독 인증기관·개인회원 무료
        The objective of this study is to examine the effect of preload and different types of hybrid FRPs (Fiber reinforced polymers) to the structural behaviors of reinforced concrete (RC) beams retrofitted with hybrid FRPs under sustaining loads. For the experimental study, FRP retrofitted RC beams are fabricated and subjected to four point loading. The experimental results show that preload and the orders of attached FRP layers have influence on FRP strengthening effect. Also, for the preliminary FEA study, FE models are generated to simulate the experiments. The analytical results are compared with the experimental results and show good agreements.
        89.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 들어 슬래브 차음성능에 대한 관심이 커지고 있으며 이에 대응하여 슬래브 두께 증가가 요구되고 있다. 또한 건축물의 효율적인 공간 활용을 위하여 장스팬의 바닥판 시스템이 많이 사용되고 있다. 이러한 요구를 만족하기 위해 개발된 바닥판 시스템중의 하나가 2방향 중공슬래브이다. 2방향 중공슬래브의 구조적 성능을 확인하기 위해서는 지진이 발생하였을 때의 안전성에 대한 검토가 반드시 필요하다. 따라서 본 연구에서는 재료비선형 시간이력해석을 통하여 2방향 중공슬래브의 지진하중에 대한 거동을 평가하였다. 효율적인 시간이력해석을 위하여 기존에 제안된 등가플레이트 모델을 사용하였고, 또한 유효보폭법을 적용한 비선형 모델을 이용하여 2방향 중공슬래브를 적용한 예제구조물의 내진성능을 평가하였다. 이를 통하여 2방향 중공슬래브를 사용한 구조물이 동일한 슬래브 두께의 일반 플랫 플레이트 구조물에 비하여 내진성능이 저하되지 않음을 확인 할 수 있었다.
        4,000원
        90.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라 공동주택의 대부분을 이루는 철근콘크리트(RC) 벽식 구조의 지진에 대한 거동을 예측하기 위해 신뢰성이 있으며 사용하기 간편한 해석모델의 수립이 필요하다. 본 논문은 기 수행된 RC 전단벽 부분구조의 횡 하중 반전주기 실험결과를 기준으로 하여 PERFORM 3D에서 가용한 RC벽 요소 및 보 기둥 요소 해석모델을 응용하여 최대한 실험결과와 근접한 결과를 주는 모델을 수립하였다. 전체 및 국부거동에 있어서 이 해석결과를 실험결과와 비교함으로써 해석의 신뢰성과 한계성을 확인함과 동시에, 실험에서 파악하기 어려운 내부 저항력의 구성, 전체 구조물의 저항 메카니즘에 대한 정량적인 분석을 제시한다.
        4,000원
        91.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대공간구조물은 일반 라멘구조와는 다른 동적특성을 가지고 있으며, 이런 동적특성에 관해 많은 연구가 수행되고 있다. 그러나 대부분의 연구는 특정 형태의 대공간구조물에 대해 수행되었으며, 내진설계를 위해 직접적으로 이용 가능한 연구결과는 매우 제한적이다. 본 연구에서는 대공간구조물의 기본적인 동적특성을 내재한 트러스-아치구조물을 대상으로 양단의 기둥의 길이가 다른 경우에 트러스-아치구조물의 지진응답변화를 분석하고자 한다. 양단 기둥 길이의 차이에 따라, 가속도 응답이 수평방향에 비해 수직방향에서 더 많은 영향을 받는다. 따라서 상부구조물을 지지하는 하부구조물의 강성이 다른 경우에 대공간구조물의 내진설계에 있어서 수직방향 응답에 대한 고려가 더욱 많이 요구된다.
        4,000원
        92.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the analysis of impact damage behavior of a reinforced concrete structure that undergoes both a shock impulsive loading and an impact loading due to the air blast induced from an explosion is performed. Firstly, a pair of multiple loadings are selected from the scenario that an imaginary explosion accident is assumed. The RC structures strengthened with advanced composite materials (ACM) are considered as a scheme for retrofitting RC wall structures subjected to multiple explosive loadings and then the evaluation of the resistant performance against them is presented in comparison with the result of the evaluation of a RC structure without a retrofit. Also, in order to derive the result of the analysis similar to that of real explosion experiments, which require the vast investment and expense for facilities, the constitutive equation and the equation of state (EOS) which can describe the real impact and shock phenomena accurately are included with them. In addition, the numerical simulations of two concrete structures are achieved using AUTODYN-3D, an explicit analysis program, in order to prove the retrofit performance of a ACM-strengthened RC wall structure.
        4,000원
        93.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In construction industries, new construction materials are needed to overcome some problems associated with the use of conventional construction materials due to the change of environmental and social requirements. Accordingly, the requirements to be satisfied in the design of civil engineering structures are diversified. As a new construction material in the civil engineering industries, fiber reinforced polymeric plastic (FRP) has a superior corrosion resistance, high specific strength/stiffness, etc. Therefore, such properties can be used to mitigate the problems associated with the use of conventional construction materials. Nowadays, new types of bridge piers and marine piles are being studied for new construction. They are usually made of concrete filled fiber reinforced polymeric plastic tubes (CFFT). In this paper, a new type of FRP-concrete composite pile which is composed of reinforced concrete filled FRP tube (RCFFT) is proposed to improve compressive strength as well as flexural strength. The load carrying capacity of proposed RCFFT compression member is discussed based on the result of experimental and analytical investigations.
        4,000원
        94.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        적층고무 면진장치의 전단강성 뿐만 아니라 인장강성 및 압축강성을 실험적으로 구한 후 비선형 해석 프로그램을 이용하여 면진장치를 모델링 하였다. 수평력을 받는 면진된 골조의 면진장치에 전도에 의한 인장응력이 발생되게 하기 위하여 큰 초기변위를 부여한 자유진동 실험을 해석적으로 수행하였다. 적층고무 면진장치는 인장에 약하기 때문에 면진장치에서의 들림 현상을 해석적으로 구하기 위하여 면진장치의 수직방향 강성들이 해석 모델에 적절히 반영되어야 한다.
        4,000원
        95.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공간구조의 지붕을 지지하는 기둥상단부에 탄소성기구를 설치하여 설계 하중을 초과하는 지진동이 가해졌을 때 이 기구의 탄소성 이력거동을 통하여 지진에너지가 흡수되는 효과를 검토한다. 이 효과로 지붕트러스로 전달되는 지진에너지가 저감되는 것을 입증하고 이러한 원리를 공간구조물의 제진설계에 활용할 수 있음을 입증한다. 트러스 형식의 지붕구조에 설계하중 이상의 외력이 가해지는 경우에는 구성부재의 좌굴파괴로 인한 건물전체의 취성붕괴가 예상되기 때문에 이러한 상황에서 구조안전성을 확보하는 설계법이 요망되며, 이 논문은 트러스 지붕에 전달되는 지진에너지를 감소시키는 설계방법을 제안하고 있다.
        4,000원
        96.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 콘크리트 세그먼트 공법은 품질관리가 용이하고 비용 및 공사기간을 단축할 수 있으나 각 세그먼트의 조립으로 인한 접합부의 응력집중 및 큰 변위로 인해 구조적으로 불리한 거동을 보여 많은 장점에도 불구하고 폭넓은 적용에 있어 그 한계가 발생한다. 이에 본 연구에서는 구조 성능이 개선된 프리캐스트 세그먼트 접합부를 제안하고 실험을 통하여 균열 및 파괴양상, 변형률, 최대하중, 변위 연성도의 측면에서 제안한 접합부의 구조 성능을 평가하고자 하였다. 본 연구에서는 시공성 및 구조성능을 고려하여 전단키 및 포스트텐션, 강봉 등의 적용여부를 변수로 한 접합부를 제안하고 이에 대해 정적 재하 실험을 수행하였다. 실험 결과, 전단키 및 포스트텐션을 적용한 SGSP 실험체는 최대하중의 측면에서 일체형 실험체에 비해 약 86%에 준하는 내력을 보였으며 연성 측면에서는 일체형 실험체의 연성 능력 이상의 연성거동을 보임으로써 제안한 접합부의 개선된 구조성능 및 적용 가능성을 확인할 수 있었다.
        4,000원
        97.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 선형이론을 바탕으로 한 이산계열 대공간구조물의 크기최적화에 따른 후좌굴 거동의 변화에 대하여 조사하고 그 결과를 기술하였다. 먼저 공간구조물의 최적의 부재크기 패턴을 조사하기 위하여 수학적 프로그래밍 기법을 도입하였다. 이때 최소화 해야하는 공간구조물의 전체 부재의 중량을 목적함수로 이용하고 절점에서 발생하는 변위 값과 각 부재에서 발생하는 응력 값을 허용치 이하로 제한하는 제약조건으로 사용하였다. 크기최적화를 통하여 도출된 최적 부재패턴을 가지는 공간구조물의 후좌굴 거동을 통합 비선형해석기법으로 해석하고 그 결과를 분석하였다. 수치해석을 통하여 크기최적화에 따른 공간구조물의 후좌굴 거동의 변화는 매우 큰 것으로 나타났으며 이러한 후좌굴 거동의 변화에 대한 예측과 분석결과가 공간 구조물의 설계에 고려되어야 할 것으로 판단된다. 또한 본 연구에서 제시한 수치해석 결과는 이산계열 대공간구조물의 설계에 기본 데이터로 제시하였다.
        4,000원
        98.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 Total Lagrangian(TL)과 Updated Lagrangian(UL)을 사용하여 구조물 하부에 케이블을 연결하고, 그 케이블에 인장력을 가하여 구조물의 처짐을 제어하는 언더텐션 시스템에 있어서 케이블의 인장력에 따른 구조물의 처짐 거동의 변화와 각 부재력을 비교함으로서 언더텐션 시스템의 효율성을 검증하는데 있다. 일반적인 빔과 거더로 이루어진 구조와는 달리 언더텐션 시스템에서는 상부에서는 하중을 하부 케이블의 인장력을 이용하여 그 하중을 양 단부로 전달하게 된다. 언더텐션 시스템은 스트럿의 개수와 길이, 케이블의 초기 인장력의 크기에 따라서 그 효과가 다르게 나타날 수 있다. 또한 케이블이 설치된 장스팬 구조의 경우, 그 거동에 있어서 비선형성적 거동이 크게 나타나게 된다. 따라서 본 논문에서는 선형과 비선형해석 결과를 비교함으로써 비선형해석의 필요성에 대하여 논의하고자 한다.
        4,000원
        99.
        2009.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 반복 횡하중 하에서의 기둥부재와 보-기둥 연결부에 대한 구조 성능 확인을 위하여 기 수행된 실험을 토대로 해석모델을 수립하고 사용 프로그램의 유용성과 실용성을 평가하는 것을 목적으로 하였다. 기존 연구자들에 의해 제안된 콘크리트와 철근의 이력 모델을 비선형 해석 프로그램인 PERFORM3D에 적용하여 수행되었다. 결과로서, 반복 횡하중 하의 비보강 보-기둥 연결부재의 해석과 실험결과가 비교적 일치함을 확인하였다. 이로써 입증된 비보강 시험체의 해석 모델에 탄소와 아라미드 섬유시트 그리고 비좌굴 가새를 추가 적용하여 실험결과와 비교.검증하여 내진 성능 보강의 해석모델을 수립하였다. 이는 기존 구조물에 대한 보강에 있어서, 해석을 통한 사전 성능 검토에 활용함으로써 시간과 물질적 측면에서의 경제성 도모에 기여할 것으로 예상된다.
        4,000원
        100.
        2008.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Growth behavior of InGaN/GaN self-assembled quantum dots (QDs) was investigated with respect to different growth parameters in low pressure metalorganic chemical vapor deposition. Locally formed examples of three dimensional InGaN islands were confirmed from the surface observation image with increasing indium source ratio and growth time. The InGaN/GaN QDs were formed in Stranski-Krastanow (SK) growth mode by the continuous supply of metalorganic (MO) sources, whereas they were formed in the Volmer-Weber (V-W) growth mode by the periodic interruption of the MO sources. High density InGaN QDs with 1~2nm height and 40~50nm diameter were formed by the S-K growth mode. Dome shape InGaN dots with 200~400nm diameter were formed by the V-W growth mode. InN content in InGaN QDs was estimated to be reduced with the increase of growth temperature. A strong peak between 420-460 nm (2.96-2.70 eV) was observed for the InGaN QDs grown by S-K growth mode in photoluminescence spectrum together with the GaN buffer layer peak at 362.2 nm (3.41 eV).
        4,000원
        1 2 3 4 5