This study proposes an RCS composite damping device that can achieve seismic reinforcement of existing buildings by dissipating energy by inelastic deformation. A series of experiments assessing the performances of the rubber core pad, hysteretic steel slit damping device, and hybrid RCS damping device were conducted. The results showed that the ratios of the deviations to the mean values satisfied the domestic damping-device conformity condition for the load at maximum device displacement in each direction, at the maximum force and minimum force at zero displacement, as well as the hysteresis curve area. In addition, three analysis models based on load-displacement characteristics were proposed for application to seismic reinforcement design. In addition, the validity of the three proposed models was confirmed, as they simulated the experimental results well. Meanwhile, as the shear deformation of the rubber-core pad increased, the hysteretic behavior of super-elasticity greatly increased the horizontal force of the damping device. Therefore, limiting the allowable displacement during design is deemed to be necessary.
The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.
본 논문는 개폐식 대공간 구조물의 지진하중에 대한 동적응답을 줄이기 위한 목적으로 파라메트릭 설계 기법을 적용한 TMD에 관한 연구이다. 인공지능 알고리즘을 이용하여 감쇠장치의 설치 위치를 자동 탐색하는 컴포넌트를 개발하였다. 이는 구조물의 동적응답을 실시간으로 확인하고, 구조물의 감쇠장치 최적의 위치를 찾을 수 있을 있다. 또한, 여러 대안에 대한 감쇠장치 질량의 최적 값을 찾아주며, 지붕의 열린 상태와 닫힌 상태에 모두 효과적으로 적용될 수 있는 설계안을 찾을 수 있다.
최근 우리나라는 대규모 지진이 빈번히 발생하고 있으며, 유감지진의 발생 규모 및 빈도가 급격히 증가하고 있어 지 진피해 저감 기술에 대한 관심이 증대되고 있다. 기존 지진피해 저감 기술은 구조물의 단면적을 크게하여 강성을 증가시키는 방법으로 과도한 설계 및 시공이 발생하여 상당한 비용이 소요되고 경제적인 측면에서 비효율적이다. 구조물에 대해 지진하중 으로부터 효율적으로 대응하기 위한 내진설계 방법에는 제진기술이 있다. 제진기술에 활용되는 제진장치는 지진 발생 후 재료의 항복으로 인해 장치의 손상 및 파괴가 발생하여 교체가 불가피하고 시간 및 비용이 소요된다. 따라서 이 연구에서는 기존 제진기술의 단점을 보완하기 위하여 에너지 소산 능력 및 복원력이 우수한 초탄성 형상기억합금 및 폴리우레탄 적용 자동복원 감쇠장치의 구조실험을 수행 및 분석하여 지진 발생 후 지속적으로 활용 가능한 댐퍼 장치에 대한 연구를 수행하였다.
In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.
In this study, a design procedure for the practical application of the dampers to building structures under earthquake loads was presented by using earthquake response spectrum. Nonlinear time history results using a 10 story building structure installed with damper verified the effectiveness of the proposed procedure by showing that the structural response could be reduced to the target performance level for seismic loads. Since the proposed design procedures are based on response spectrum seismic analysis result of the original structure, the capacity, location and the number of damper and the consequent response reduction effects can be preliminarily determined without performing the nonlinear time history analysis.
In this study, the effectiveness of a multi-action hybrid damper (MHD) composed of lead rubber bearing (LRB) and friction pad was verified in terms of seismic performance improvement of a frame structure. The LRB and the friction elements are connected in series, so the LRB governs the intial small deformation and the friction determines large deformation behavior. Cyclic loading tests were conducted by using a half scale steel frame structure with the MHD, and the results indicated that the structure became to have the stable trilinear hysteresis with large initial stiffness and first yielding due to the LRB, and the second yielding due to the friction. The MHD could significantly increase the energy dissipation capacity of the structure and the hysteresis curves obtained by tests were almost identical to the analytically estimated ones.
This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.
구조물의 성능을 개선하기 위하여 다양한 진동제어장치가 사용되고 있다. 대부분의 제진장치는 구조물의 감쇠비를 증가시킴으로써 성능개선효과를 유도하기 때문에 증가된 감쇠비는 제진장치에 의한 구조물의 성능을 평가하는 중요한 지표가 될 수 있다. 본 연구에서는 강풍 등으로 제진장치가 운영 중인 상태에서 구조물의 응답만을 이용하여 각 모드에 증가된 등가감쇠비를 추정하는 프로세스를 개발하고 이를 성능개선효과를 평가하는데 활용하고자한다. 제진장치가 설치된 구조물은 비고전 감쇠시스템이므로 상태공간 모드분해법을 이용하여 계측응답으로부터 모드 응답을 구하고, 분해된 모드응답에 가상 동적 진동기를 적용하여 각 모드에 증가된 감 쇠비를 구하였다. 제안된 제진장치 설치 구조물 감쇠비 추정법을 검증하기 위하여 수동형 제진장치로 카고메 점탄성 댐퍼를, 능동형 제진장치로 능동질량감쇠기를 구조물에 적용하여 각 제진장치에 의한 감쇠비를 추정한 결과 매우 정교하게 예측 가능함을 알 수 있었다.
In this study, effectiveness of seismic retrofitting methods using passive damping devices was investigated through numerical analyses of short-period structures under earthquakes which have short-duration and high-frequency impulse characteristics similar to Geyongju earthquakes. Displacement spectra of elastic systems and ductility demand of inelastic systems were evaluated by increasing viscous or friction damping. The damping devices could reduce responses of the structures with shorter structural period than 0.2s. The earthquakes similar to impulse load did not induce the responses of the structures with longer period than 0.4s, and the effects of the damping devices which generates damping forces proportional to structural responses became insignificant.
본 연구에서는 풍하중을 받는 건물에 설치된 다중거동 복합 감쇠장치(MHD)의 성능을 평가하고, MHD 예비설계 절차를 제안하였다. MHD에 의해 증가된 등가감쇠비와 그에 따른 건축구조기준에 근거한 응답저감계수를 예상한 후, 풍하중 스펙트럼에 의해 생성된 풍하중을 사용하여 20층 철골구조물에 대한 시간이력 해석을 수행하였다. 해석결과를 통해 얻어진 층변위 및 층간변위 평균 응답 감소율은 각각 0.585 및 0.525로, 이는 제안한 예비설계과정에서 추정된 응답감소계수 0.6과 거의 동일한 수치임을 확인하였다. 이로부터 제안된 방법을 사용하여 MHD의 제어효과를 효과적으로 평가할 수 있음을 확인하였다.
본 연구에서는 파라매트릭 모델링 기법을 통해 다양한 대안을 고려할 수 있도록 개발된 StrAuto(이하 전산플랫폼)을 이용하여 감쇠장치에 따른 감쇠비 증가 효과와 풍하중 저감효과를 평가하였다. 비정형 초고층구조물의 수많은 구조시스템 대안선정을 지원하는 전산플랫폼은 설계자 또는 엔지니어에게 초기 대안을 결정하는데 있어 유용한 도구가 된다. 감쇠장치의 용량 및 추가 요구감쇠비의 크기를 산정하는 과정에서 중요한 원 구조물의 감쇠비에 대한 추정은 풍하중에 대한 실계측 자료를 기반으로 수행된 국내외 관련 연구의 결과를 사용하였다. 감쇠장치는 층간 설치형 수동형 감쇠장치와 질량형 능동형 감쇠장치 두 가지 유형을 고려하였다. 감쇠장치에 의해 추가되는 감쇠비는 FEMA에서 제안한 식을 이용하여 등가 정적 해석을 수행하여 산정하였다. 전산 플랫폼 내부에 감쇠장치의 용량을 최적화하는 알고리즘을 내장함으로써 최적의 감쇠장치 설계안을 자동적으로 도출할 수 있다. 감쇠장치 설치에 따른 물량저감 효과는 풍하중 저감계수로 평가될 수 있으며, 455m 높이의 초고층구조물을 대상으로 제안한 방법의 유효성을 검증하였다. 제안한 방법을 사용하여 비선형 시간이력 해석을 통해 얻어진 지붕층 변위와 층별 전단력을 근사적으로 추정할 수 있음을 확인하였다.
본 논문에서는 해상 시추작업을 위한 heave compensation system의 시뮬레이션 모델을 개발하였다. 우선 시뮬레이션을 위하여, 다물체계 동역학 커널을 개발하였다. 다물체계 동역학 커널은 입력 받은 heave compensation system 시뮬레이션 모델의 운동학적 정보를 이용하여 recursive Newton-Euler formulation 방법을 기반으로 운동방정식을 자동으로 구성하고, 수치적으로 해를 계산하는 기능을 한다. 그리고 해상 시추선에 작용하는 외력을 계산하기 위하여 유체 정역학적 힘과 유체 동역학적 힘을 계산하는 모듈을 개발하였다. 이와 같이 개발한 커널과 모듈들을 적용하여 해상 시추선의 hoisting system 동적거동 해석을 수행하고, 관절에서의 구속력을 계산하였다.
토목구조물에 능동형 질량동조감쇠장치를 설치할 경우에 설치장소의 크기는 제한되며 그에 따라 질량감쇠증기의 최대진폭이 제한되는 것이 일반적이다. 이 연구에서는 벽체 스프링과 고정장지를 이용하여 능동형 질량동조감쇠장치의 진폭을 제한하면서도 제어성능을 적절히 유지시킬 수 있는 제한진폭 능동형 질량동조감쇠장 치를 제안하였다. 이 제어장치는 질량감쇠장치의 진폭이 작을 경우에는 일반적인 능동형 질량동조감쇠장치로 작동하고 진폭이 정해진 값을 초과하면 제한진폭 능동형 질량동조감쇠장치로 작동하게 된다. 이러한 동작원리의 수학적 정식화를 통하여 새로운 제어 알고리즘을 제시하였다. 제한진폭 능동형 질량동조감쇠장치의 다양한 설계인자에 대한 파라미터 연구를 수행하였고, 그 성능을 기존의 능동형 질량동조감쇠장치와 비교하여 살펴보았다. 제한진폭 능동형 질량동조감쇠장치의 정현하중 및 충격하중에 대하여 일반적 능동형 질량동조감쇠장치와 비교하여 제어효과가 크게 떨어지지 않으면서 질량감쇠장치의 최대진폭을 상당히 줄일 수 있어 그 유용성을 확인할 수 있었다. 랜덤하중에 대한 해석의 경우는 질량감쇠장치의 최대진폭이 크게 감소하면서 주구조물의 최대진폭은 거의 증가되지 않는 개선된 결과가 관찰되었다
본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물의 동적거동을 예측할 수 있는 수치해석모델을 제안한다. 하이브리드 면진장치는 MR 감쇠기와 마찰진자시스템(FPS)으로 구성된다. MR감쇠기의 동적거동을 모형화하기 위하여 뉴로-퍼지 모델을 사용한다. 다양한 변위, 속도, 전압의 조합을 사용하여 MR 감쇠기의 성능실험을 수행한 후 얻어진 데이터를 이용하여 MR 감쇠기 뉴로-퍼지 모델을 ANFIS로 학습시킨다. FPS의 모형화는 본 연구에서 유도한 비선형 모델식에 근거하여 뉴로-퍼지 모형화방법을 사용하여 이루어진다. 본 연구에서는 MR 감쇠기로 전달되는 제어전압을 조절하기 위하여 퍼지논리제어기를 사용한다. 다양한 지진하중을 사용한 진동대 실험을 통하여 얻은 실험체의 동적응답과와 뉴로-퍼지 모형화방법을 사용한 수치해석의 결과를 비교한다. 뉴로-퍼지 모델을 사용하여 MR 감쇠기와 FPS를 모형화해서 수치해석을 수행한 결과 하이브리드 면진장치의 동적거동을 매우 정확하게 예측할 수 있었다.