The interest for the stability of the structures against earthquake, which is increasing recently, is rapidly increasing. But, currently, school buildings among the reinforced concrete(RC) structures in Korea are not designed with seismic design or there are many cases of being designed with the old seismic design code, so it is estimated to have not only lives but also a great deal of economic damage are likely to occur when an earthquake occurs. In this study, proposed horizontal friction system(HFS) with rotary friction damper installed as a method to reinforce strength and hardness and to increase ductility for the low story structure of 5 stories or lower such as school buildings. For the seismic retrofitting design with horizontal friction system in which rotary friction damper is installed, Peak displacement response ratio according to elastic and inelastic behavior and ductility demand is calculated to decide elastic stiffness and strength of the HFS, design model and procedure to decide the capacity of HFS thereof is decided, and the feasibility and performance are reviewed through pushover analysis.
본 연구에서는 교량의 내진보강방안을 합리적으로 결정하기 위하여 기존교량 및 보강된 교량의 지진하중에 대한 손상가능성을 이용하여 보강에 따른 내진성능 향상효과를 분석하였다. 교량의 내진보강에 따른 효과는 기존교량 및 보강된 교량에 대해 평가된 보강우선순위의 변화를 통하여 분석하였다. 이를 위하여 본 연구에서는 선행적으로 교량의 사용수명동안에 발생가능한 지진하중에 의한 지진취약부위의 손상확률과 손상으로 인해 예상되는 총 손실비용에 근거한 지진취약부위별 가중치를 이용하여 교량별 내진보강 우선순위를 결정할 수 있는 평가기법을 제안하였다. 제안된 평가기법의 타당성을 검증하기 위하여 다른 형식을 갖는 4개의 PSC 거더교를 대상으로 내진보강 우선순위를 평가하였다. 또한 각 지진취약부위별로 내진 보강된 교량에 대해 재평가된 순위지수를 기존교량에 대해 평가된 결과와 비교함으로써 각 교량별로 적용된 보강기법의 적합성을 검토하였다. 기존교량 및 보강된 교량에 대한 모의분석결과로부터 적용된 보강방안에 따라 해당취약부위의 손상가능성은 상당히 감소될 수 있으나 반면에 인접한 지진취약부위의 손상가능성은 증가되는 경향을 보이는 것으로 나타났다. 그러므로 기존교량에 대한 합리적인 보강방안을 결정하기 위해서는 내진보강에 따른 교량의 전체적인 거동특성변화에 따른 보강효과분석이 필수적으로 요구되며, 이는 본 연구에서 제안한 내진보강 우선순위 평가기법에 따라 기존교량 및 보강된 교량의 보강우선순위를 평가, 비교함으로써 효과적으로 수행될 수 있는 것으로 분석되었다
In this study a seismic retrofit scheme for a reinforced concrete shear wall structure using steel slit dampers was presented. The stiffness and the strength of the slit damper used in the retrofit were verified by cyclic loading test. Genetic algorithm was applied to find out optimum location of the slit dampers. The effects of the slit dampers on the seismic retrofit of the model were compared with those of jacketing shear walls. The seismic performance of the model structure with optimally positioned slit dampers was evaluated by nonlinear static and dynamic analyses. Based on the analysis results, the simple procedure for determining required damping ratio using capacity spectrum method along with the damper distribution pattern proportional to the inter-story drifts was validated.
The double frame system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The DFS retrofit system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed DFS system
In this study, the optimal performance based seismic retrofit method for fiber-reinforced polymer (FRP) jackets in existing reinforced concrete (RC) frames is presented. This optimal method minimizes the amount of FRP material while satisfying the constraints on the maximum inter-story drift, maximum strain of concrete, and shear failure prevention of columns. Both of shear reinforcement for preventing shear failure of columns and flexural reinforcement for improving the flexural capacity of columns are simultaneously considered. This method is applied to 3-story RC frame and the reinforced locations and the numbers of FRP reinforcement plies are obtained.
조적조 구조물은 전 세계적으로 중·저층 주거시설, 상업시설, 종교용 건축물, 학교, 관공서 등의 용도로 폭넓게 사용되어 왔다. 그러나 조적벽체는 조적개체와 모르타르의 이질재료를 접착하여 쌓는 방식의 구조벽체로 지진과 같은 횡력 발생 시 접착력을 잃거나 미끄러지면서 파괴될 수 있다. 본 연구는 이러한 문제점을 해결하고자 조적식 구조물의 내진보강 기법을 제안하였으며, 진동대 실험을 통하여 내진 성능을 검증하였다. 진동대 실험 결과, 본 연구에서 제안한 내진보강 기법을 이용한 벽체는 한국 건축설계기준이 제시하는 내진 기준인 0.14g와 미국 IBC에서 제시하는 내진 기준인 0.4g에서 모두 최종 파괴에 도달하지 않았다. 그러나, 0.14g 이상의 지진을 경험한 면외방향 실험체의 경우 급격한 강성저하가 관찰되어, 적절한 보수·보강이 필요할 것으로 예측된다.