Purpose : We have investigated the vanatwn between ocular components and re(ractive error v.~lh various age groups between 20 to 69 years old. Methods : Refractive error and ocular components were measured in 100 adults (200 eyes) v.~th healthy eyes. Spherical equivalenl. corneal power and mean corneal radius were measured using a Canon RK-Fl autorefractor. Anterior chamber depth and axial length measurements were made using IOL Master. AUCR ratio was calculated by dividing axial length measurements by mean corneal radius. Power vector analysis was used to analyze the refractive error which is expressed with three vectors : M, Jo. J 15· Results : Measured Spherical equivalent values were -1.51±2.480(males -1.33± 2.070, females -1.63±2.670). and showed significant age groups dependence. Measured AUCR ratio values were 3.15±0.15(males 3.16±0.12. females 3.15±0.17). and showed significant age groups dependence. Prevalence of spherical equivalent were as follows : myopesOlleyes. 55.5%). emmetropes(49eyes. 24.5%). hyperopes (40eyes. 20%), and astigmatic eyes(89eyes, 44.5%). As increasing the age from 20s to 60s, M components of power vector analysis showed the change myopia to hyperopia(from -3.44±2.460 to 0.88±1.270). Jo components of power vector analysis changed with-the-rule(WfR) to against-the-rule(ATR)(0.41±0.67D for 20s and -0.01± 0.350 for 40s). J4s components of power vector analysis were -0.67±0.140 for 20s and 0.09±0.270 for 50s. ln J.,s components analysis. the cylinder axis observed near 135 degree for 20s and 45 degree for 50s. Linear regression analysis showed the strong negative correlation between axial length and spherical equivalent(r = -0. 73. p < 0.0001). The correlation between AUCR ratio and spherical equivalent showed the most strong negative dependence(r = -0.82, p < 0.0001). Conclusion : Prevalence of myopia showed 55.5%0lleyes) in 200 eyes. Refractive error showed the change from myopia to hyperopia and total astigmatism showed the change from with-the-rule to against-the-rule with increasing ages. Analysis of biometric data showed that AUCR ratio has the highest negative correlation with spherical equivalent.
목 적 : 굴절이상도 및 굴절이상과 안광학 상수의 상호연관성을 알아보기 위하여 수행되 었다. 방 법 : 안질환이 없는 건강한 젊은 성인 68명, 68안(우안)을 대상으로 Topcon KR-8800 을 사용하여 등가구면 굴절력, 각막 굴절력, 각막 곡률반경을 측정하였다. 전방 깊이, 수정체 두께, 유리체 깊이, 안축장 길이는 A-Scan Ultrasonography를 사용하여 측정하였으며, AL/CR비는 안축장 길이를 평균 중심 각막 곡률반경으로 나누어 계산하였다. 결 과 : 등가구면 굴절력은 -3.55±2.84D(남자 -3.73±3.21D, 여자 -3.40±2.55D)로 남녀사이의 유의한 차이가 없었다. 전체 68안 중 근시 60안(88.24%), 정시 6안(8.82%), 원 시 2안(2.94%)으로, 등가구면 굴절력은 근시 -4.02±2.69D, 정시 -0.33±0.13D, 원시 +0.88±0.18D로 측정되었다. 원주 굴절력이 0.75D 이상은 35안(51.47%)으로, 직난시 33안 (94.29%), 사난시 2안(5.71%)으로 나타났으며 전난시와 각막난시는 높은 음의 상관관계를 보였다(r = -0.84, p < 0.0001). 굴절이상에 의한 AL/CR비는 정시 2.93±0.02, 근시 3.12± 0.14, 원시 2.87±0.01로 측정되었으며, 등가구면 굴절력과 가장 높은 상관관계를 나 타냈다(r = -0.88, p < 0.0001). 결 론 : 굴절이상은 안축장 길이에 의한 것이 중요한 원인으로 본 연구에서도 안축장 길 이는 등가구면 굴절력과 높은 음의 상관관계를 보였으며, AL/CR비가 등가구면 굴절력과 가 장 높은 음의 상관관계를 보여 선행연구와 일치하였다. 난시분포는 도난시와 사난시에 비해 직난시가 많은 것으로 나타났으며 전난시와 각막난시는 높은 음의 상관관계를 보여 전난시의 중요한 원인이 각막난시에 의한 것임을 알 수 있었다.