In reinforced concrete structures, carbonation phenomena associated with deterioration is important. So, this study conducted a visual inspection and a concrete durability test in Precise Safety Diagnosis, analyzed the result, and tried to suggest a reasonable repair method and range of concrete carbonation.
reinforced concrete structures, carbonation phenomena associated with deterioration is important. So, this study conducted a visual inspection and a concrete durability test in Precise Safety Diagnosis, analyzed the result, and tried to suggest a reasonable repair method and range of concrete carbonation.
Reinforced concrete structures are deteriorated in a few decades due to various causes, such as carbonation. Therefore it is important to evaluate the accurate carbonation depth in order to secure the durability of the structure. In this paper, carbonation depth by drilling excavation and splitting core sample are compared. Also, the procedure for estimating the appropriate repair zone is proposed, with the result of carbonation depth and steel bar detection.