        2.
        2019.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), Ti/RuO2, and Ti/IrO2 electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.
        4,000원
        6.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이염화이소시아뉼산나트륨(NaDCC) 주입 선박평형수처리설비(BWMS, ballast water treatment system)에 의해 처리된 배출수 내에는 브롬 및 염소계열의 활성물질과 소독부산물질(DBPs, disinfection by-products)들이 포함되어 있다. 본 연구에서는 NaDCC로 처리된 선박평형수가 해양환경에 미치는 생태위해성을 파악하기 위하여 생태독성시험(WET test, whole effluent toxicity test)과 생태위해성평가(ERA, ecological risk assessment)를 수행하였다. 배출수독성 시험종은 규조류(Skeletonema costatum, Navicula pelliculosa), 녹조류(Dunaliella tertiolecta, Pseudokirchneriella subcapitata), 로티퍼(Brachionus plicatilis, Brachionus calyciflorus) 및 어류(Cyprinodon variegatus, Pimephales promelas)로 8개의 해양 및 담수종을 이용하였다. 생태독성시험결과, 규조류 및 녹조류를 이용한 성장저해시험에서만 명확한 독성영향이 나타났으며 해수의 시험 조건에서 무영향농도(NOEC, no observed effect concentration), 최저영향농도(LOEC, lowest observable effect concentration) 및 반수영향농도(EC50, effect concentration of 50%)는 각각 25.0 %, 50.0 % 및 > 100.0 %로 가장 민감한 영향을 나타냈다. 하지만 로티퍼 및 어류를 이용한 독성시험의 경우 모든 염분 구간에서 독성영향이 나타나지 않았다. 한편, 배출수에 대한 화학물질분석결과, bromate, isocyanuric acid, formaldehyde, chloropicrin과 trihalomethanes (THMs), halogenated acetonitriles (HANs), halogenated acetic acid (HAAs) 등 총 25개의 소독부산물질들이 검출되었다. ERA결과, 25 개의 소독부산물질들 중, 지속성(P), 생물축척성(B) 및 생물독성(T)의 특성을 모두 보이는 물질은 없었다. 예측환경농도(PEC, predicted environmental concentration) /예측무영향농도(PNEC, predicted no effect concentration) 비율은 일반적인 항구 환경에서는 모든 물질이 1.0을 초과 하지 않았지만 선박 최 인접지역의 경우 Isocyanuric acid, Tribromomethane, Chloropicrin 및 Monochloroacetic acid가 1.0을 초과하여 위해성이 있을 것으로 나타났다. 하지만 실제 배출수를 이용한 생태독성시험결과의 NOEC (25.0%)를 적용한 결과 NaDCC로 처리된 선박평형수가 해양에 배출되었을 때 선박 최 인접지역을 포함한 일반적인 항구 환경에 수용 불가한 생태위해성을 가지지 않는 것으로 판단된다.
        4,300원
        8.
        2017.11 구독 인증기관·개인회원 무료
        Effluent treated by an NaDCC injection method in Ballast water management system (BWMS) contains reactive chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on marine environment. WET testing was carried out for four marine pelagic and freshwater organisms, i.e., diatom Skeletonema costatum, Navicula pellicuosa, chlorophyta Dunaliella tertiolecta, Pseudokirchneriella subcapitata, rotifer Brachionus plicatilis, Brachionus calyciflorus and fish Cyprinodon variegatus, Pimephales promelas. The biological toxicity test revealed that algae was the only biota that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50% (EC50) values of 25-50%, 50-100% and >100%, respectively, at three water condition, but did not show any significant toxicities on other biota. Meanwhile, chemical analysis revealed that the BWMS effluent contained total residual oxidants (TROs) below 0.03 g/L and a total of 25 DBPs such as bromate, volatile halogenated organic μ compounds (VOCs), halogenated acetonitriles (HANs), halogenated acetic acids (HAAs), chloropicrin and Isocyanuric acid. Based on ERA, the 25 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. The ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the other DBPs did not exceed 1 for General harbor environment. However, four substances (Isocyanuric acid, Tribromomethane, Chloropicrin and Monochloroacetic acid) were exceed 1 for Nearship environment. But observed toxicity in the test water on algal growth inhibition would be mitigated by normal dilution factor of 5 applied for nearship exposure. Thus, our results of WET testing and ERA showed that the BWMS effluent treated by NaDCC injection method would have no adverse impacts on marine environment.
        13.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        IMO에서 규제중인 선박평형수의 처리기술은 현재 대부분 화학적 처리법 및 전기적인 처리방 법을 주로 이용하고 있는데 이러한 방법들은 2차오염의 위험을 가지고 있으며 이를 방지하기 위하여 추 가적인 장치가 필요하다. 본 연구에서는 전단력을 활용한 물리적인 방법을 이용하여 2차 오염 없이 선 박평형수를 처리하는 방법을 연구하였다. 균일장치의 원리를 이용하여 전단응력으로 균을 파쇄시키는 원 리인데, 내부 실린더와 외부 실린더의 표면이 매끄러운 경우에는 미끄럼 현상이 나타나 효율적인 살균 효과를 얻기가 어려워서 전단응력의 크기를 변화시키는 다양한 요인 가운데 표면의 모양을 다르게 하여 두 가지 type의 장치에 대한 살균 성능을 비교하였다. 기본 장치는 cylinder type이나, 내부 실린더와 외 부 실린더에 일정 간격과 깊이로 홈을 파낸 groove type과 멸균성능을 비교하였다. 그 결과 미끄럼을 방지한 groove type에서 cylinder type보다 우수한 결과를 나타내었다.
        4,000원
        14.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to treat the ballast water by shear stress without an environmental pollution and to find out the optimal treatment conditions. The ballast water problem is issued up as the trade activated and the cargos mobilized. To improve this problem, International Marine Organization(IMO) make the rule about the ballast water treatment with specific restrictions. Although many countries have been studying about the ballast water treatment technology, there is almost no technology that can treat the microorganisms under 50μm withoutany secondary pollution. In this study, we tried to treat ballast water by applying shear stress as the physical treatment for the sterilization and tried to find out the optimal conditions including the 100% sterilizing rate and the best economic condition.
        4,000원
        15.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        선박의 항해 안전성을 유지하기 위하여 평형수 탱크에 주입ㆍ배출되는 선박평형수는 그 안에 포함되어 있는 각종 수중생물로 인하 여 지역 해양 환경에 부정적인 영향을 주고 있다. 국제해사기구(IMO)는 선박평형수를 통한 수중생물의 이동을 막기 위해, 2004년 선박평형수 와 침전물 통제 및 관리를 위한 국제협약을 채택하고 2016년 9월에 발효하여, 2017년 9월 이후 정기검사가 도래하는 모든 선박은 선박평형수 처리장치를 설치하도록 하였다. 선박평형수 처리 방식에는 활성물질을 이용하여 처리하는 전기분해식, 오존식, 약품식과 물리적인 처리방식인 필터, 자외선식 등으로 나누어 지며, 두 가지 방식을 혼용하여 사용하기도 한다. 일반적으로 비용과 효율 면에서 전기분해방식이 우수한 것으로 알려져 있다. 본 논문에서는 직접식 전기분해 선박평형수 처리장치의 기본 원리, 구성 요소, 육상 시험 내용을 고찰하였다. 육상시험은 정부시 험 시설이 설치되어 있는 KIOST 거제분원에서 300m3/h 처리 용량의 장치로 수행하였다. 이 육상시험을 통해 직접식 전기분해 선박평형수 처 리장치가 IMO에서 제시하고 있는 기준을 만족하고 다른 방식에 비해 효율적인 것을 확인하였다.
        16.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        In this study, we examined the effect of cathode from electrolysis reactor for treating ballast water. We are going to select a suitable cathode for seawater electrolysis after considering the effect on the generation of the oxidant of cathode and the electrode deposition materials adhering to the surface of cathode. Anode is Ru-Ti-Pd electrode and cathode are Ti, Pt, JP520 (Ni-Pt-Ce) electrodes. Using the cathode of the three types, experiments were conducted to examine the effects of TRO (total residual oxidants) generation concentration and RNO (N, N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation concentration (in 1, 35 psu), ohmic drop, FESEM(field emission scanning electron microscope) observation of cathode surface and EDX (energy dispersive X-ray spectroscopy) measurements of attached fouling material. The results showed that TRO generation concentration and RNO degradation concentration in according to each type of cathode are not different. The attached fouling materials were observed on the surface of Ti and the JP520 electrode by the observation of SEM after electrolysis for two hours, but it was not observed on the surface of Pt electrode. When considering the surface ohmic drop of cathode and the attached fouling materials, Pt electrode was judged as the excellent cathode.