For the OPR1000, a standard power plant in Korea, an analytical model of the containment building considering voids and deterioration was built with multilayer shell elements. Voids were placed in the vulnerable parts of the analysis model, and the deterioration effects of concrete and rebar were reflected in the material model. To check the impact of voids and deterioration on the seismic performance of the containment building, iterative push-over analysis was performed on four cases of the analytical model with and without voids and deterioration. It was found that the effect of voids with a volume ratio of 0.6% on the seismic performance of the containment building was insignificant. The effect of strength reduction and cross-sectional area loss of reinforcement due to deterioration and the impact of strength increase of concrete due to long-term hardening offset each other, resulting in a slight increase in the lateral resistance of the containment building. To determine the limit state that adequately represents the seismic performance of the containment building considering voids and deterioration, the Ogaki shear strength equation, ASCE 43-05 low shear wall allowable lateral displacement ratio, and JEAC 4601 shear strain limit were compared and examined with the analytically derived failure point (ultimate point) in this study.
벨로우즈 신축이음관은 구조적 특성으로 인해 큰 변위 용량을 갖으며 과도한 상대변위에 의한 매립 배관 시스템의 손상을 저감시키기 위해 연결부로써 사용된다. 벨로우즈 신축이음관의 내진성능 평가를 위한 연구에서 한계상태는 변형률을 적용하였지만 변형률 기반 한계상태는 벨로우즈 신축이음관의 큰 변위용량을 고려할 수 없다. 또한 벨로우즈 신축이음관의 성능평가와 한계상태 분석을 위한 해석적 및 실험적 연구는 수행된 사례가 극히 적다. 따라서 본 연구는 단조 및 반복하중을 받는 벨로우즈 신축이 음관의 해석적 연구를 통해 벨로우즈 신축이음관의 한계상태를 분석하였다. 결과적으로 단조하중 보다 반복하중을 받는 벨로우즈 신축이음관은 더 낮은 변위에서 누출이 발생하였다. 반복하중으로 인한 피 로 및 라체팅 현상으로 인해 단조하중 보다 낮은 변위의 성능을 갖는 것으로 보여진다. 따라서 반복하 중에서 관측된 변위응답을 기반으로 벨로우즈 신축이음관의 내진성능 평가를 수행하는 것이 보수적일 것으로 판단된다.