This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.
A core device of foam system is the in-line eductor and it is the device to mix the foam liquid into liquid solution proper to the use density and the mixture ratio must be kept regularly regardless of changing fluid condition of the front and rear end of the in-line eductor. However, if the flux of the pressurized water changes, the mixture ratio is not kept regularly, and so it becomes a cause which a performance of fire-extinguishing deteriorates in discharging foam liquid. I devise a method to improve it that the metering orifice type in-line eductor is improved into the metering venturi type in-line eductor, the fluctuation of the mixture ratio to the flux change of the pressurized water is minimized and the performance of fire-extinguishing is kept regularly. As this method is simple in its structure and can be designed at a low cost, it helps for maintenance as well. In the future, it seems to need the research for the metering nozzle type in-line eductor in the future.
The aim of these studies is to confirm the red and blue painting damages during the fire suppression of wooden cultural assets by using the loaded stream charge extinguishant. As a results of these experiments, the ingredients of extinguishant existing on the surface of wooden cultural assets were perfectly eliminated by the water washing only. Any changes on the surface of wooden cultural assets couldn't be detected. Moreover, any color changes of the red and blue painting didn't occur.
본 연구에서는 기존 청정소화약제 중 HFCS 계열인 HFC-125, HFC-227ea, HFC-23와 제2세대 할론 대체 소화약제 Novec 1230(F-K-5-12)을 비교해보았다. HFCS 계열 물질은 염소와 취소를 함유하지 않아 오존파괴지수(ODP)가 0으로 독성이 낮다. 그러나 지구온난화물질 6가지 중 하나로 교토의정서에 규제물질로 지정되어있다. HFCS 계열의 대체물질 중 HFC-125는 FE-25로 NOAEL은 7.5vol%, GWP는 2,800이다. HFC-227ea는 FM-200이라는 상품명으로 개발한 소화약제로 끓는점이 -16.4℃로 전역방출방식에 적합하다. NOAEL이 9vol% 이며, GWP는 2,900이다. HFC-23은 상품명 FE-13이며 NOAEL은 30vol%, GWP는 11,700이다. 제2세대 할론 대체 물질로 개발된 Novec 1230(F-K-5-12)는 탁월한 친환경성과 소화효과로 전세계 시장의 25%를 큰 규모를 차지하고 있다. 미국 3M사가 개발한 방화액으로 일명 젖지 않는 물이라 불린다. 슈퍼컴퓨터의 냉매 또는 도서관, 사무실, 컴퓨터실 등의 화재 진압용 개발된 화학물질이다. 무색·무취이며 점성 또한 물과 비슷해 용기에 따르거나 흘려보낼 수 있다. 끓는점은 49.2℃로서 상온에서 액체상태이기 때문에 압축가스보다는 다루기 쉽다. 또한 화재 시 대기에 빠르게 기화되므로 전역방출방식에 적용한다. NOAEL은 10vol%, ODP는 0이며 GWP는 1이다. 그러나 액체증기압이 매우 낮아 약제 용기에 저압으로 저장되어 다른 소화약제에 비해 멀리 이송되지 못한다. 또한 HFC-227ea, HFC-125 보다 1.5배에서 2배까지 가격이 비싸다. 기존 청정소화약제와 기존의 것을 보완해 개발된 Novec을 비교·분석 하였으나 완벽한 소화약제는 없으며 각 약제별 장·단점이 확인되었다. 이 연구를 통해 비교된 부분이 보완되어 새로운 청정소화약제 개발에 도움이 될 수 있으면 한다.
산불진화용 포 소화약제는 산불 진화효과 뿐만 아니라 자연환경에 사용되는 화학물질인 만큼 산림에 미치는 환경독성 영향을 고려하여야 한다. 하지만 현재 국내 제조, 사용되고 있는 국내외 산불진화용 포 소화약제에 대한 환경독성 및 기타 물리적 특성 기준 등이 마련되어 있지 않다. 특히 산불진화용 포 소화약제는 항공기에도 사용되고 있어 항공기 기체 금속부식에 대해 고려되어야 한다. 국내 소화약제는 소방법 기술기준규칙에 적용을 받고 있지만 산불진화용 포 소화약제에 대한 사항은 규정된 바 없어 기준이 전무하다. 이에 본 연구에서는 국내외 제조, 판매되고 있는 산불진화용 포 소화약제에 대한 진화능력, 환경 독성, 장비손상 가능성 유무 등을 조사·분석하여 산림환경독성 영향평가와 함께 진화능력단위평가, 기초 물성치 측정 등 우리나라 산불진화에 적합한 시험방법 및 소화약제 제품규격 안을 마련하였다.