The emission of particulate matter and volatile organic compounds (VOCs) from a motor vehicle painting booth was quantitatively evaluated. Most particulate matter was emitted during the spraying process, in which the PM10 concentration was 16.5 times higher than that of the drying process. When the paint was being sprayed, the particles with a diameter of 1.0~2.5 μm accounted for 39.4% and particles greater than 2.5 μm in diameter accounted for 30.6% of total particles. On the other hand, small particles less than 0.5 μm in diameter accounted for 52.4% of total particles during the drying process. In contrast to the particulate matter, high concentrations of VOCs were emitted during both spraying and drying processes. Butyl acetate, xylene, toluene, and m-ethyltoluene were the most abundant VOCs emitted from the motor vehicle painting booth. Additionally, xylene, butyl acetate, toluene, and 1,2,3-trimethylbenzene were the dominant ozone precursors. Especially, xylene exhibited the highest ozone production contribution (32.5~44.4%) among 34 species of the ozone precursors. The information obtained in this study can be used to establish a suitable management strategy for air pollutants from motor vehicle painting booths.
한반도 동남 지역에서 고농도 오존이 발생한 사례에 대해 NOx에 대한 오존의 수반민감도를 살펴보았다. 사례일에 지배적이었던 국지 순환과 고농도 오존을 모의하기 위해 WRF-CMAQ 모델을 사용하였다. 수반민감도 분석을 위해 CMAQ의 수반 모델을 적용하였다. 본 연구의 목적은 고농도 오존에 주변지역이 미친 영향을 살펴본 수용지 중심의 민감도 분석이다. 또한, 행정 구역별 기여도를 정량적으로 산정하였는데, 대구를 수용지로 하는 민감도 분석 결과 영향지역은 대구에 인접하여 포항으로 이어지는 영역과 남동쪽으로 떨어진 넓은 지역으로 나타났다. 첫 번째 영역은 고농도 사례일 당일에 배출된 NOx의 민감도가 주로 나타났고 두 번째 영역은 전 날 배출에 의한 영향이었다. 반면, 부산을 수용지로 한 경우 사례일 당일 주간의 해풍의 영향으로 같은 날의 NOx 배출 효과 보다는 전 날 배출되었던 농도에 대한 민감도가 더 중요하였다. 민감도 영향지역에 대한 단면도 분석 결과 지표부근의 NOx 수송과 함께 상층에서 이류되는 영향도 중요하였다.
This study analyzed characteristics of ozone (O3) formation regimes in Busan over a period of recent five years (2015~2019) and compared the findings with those obtained in Seoul. We employed four observed variations: early morning commuting-hour (i.e., 06:00-09:00 LST) nitrogen dioxide (NO2), peak-hour (i.e., 12:00-16:00 LST) O3, 8-hour average O3 (MDA8 O3), and △O3 (=O3_max- O3_min) in Busan and Seoul. In addition, the NO2-O3 relation was assessed to interpret which of NOx-limited or volatile organic compound (VOC)-limited was dominant. In Busan, the annual mean O3 concentration was relatively higher than in Seoul, whereas there were fewer high-concentration days. The Pearson correlation coefficients (R) between Early morning-hour NO2 and the Peak-hour O3 was positive (but close to zero) in Busan and negative in Seoul. Likewise, the R between the Early morning-hour NO2 and the △O3 showed a relatively considerable positive correlation (R=+0.4~0.5) in Busan, while a weak positive correlation (R=+0.1~0.2) in Seoul. From this result, it can be inferred that the O3 formation regime in Busan was intrepreted to be nearly neutral or relatively closer to the NOx-limited regime than Seoul, while Seoul to the VOC-limited regime. The study findings imply that O3 control strategies should be applied differently in Busan and Seoul. The results here were inferred from surface NO2 and O3 observations, and the varification studies based on in-situ VOCs measurements would be needed.
We studied the ozone concentrations generated by low-temperature dielectric barrier discharge plasma reactor after adding air and phytoplankton to control the ozone concentrations in seawater. We also examined the numbers of bacteria and Vibrio spp. after treatment using the plasma reactor. As the airflow rate was increased, more ozone was removed. Although marked variation in the ozone decrease was observed with and without airflow, the rate of ozone removal did not increase proportionately with the airflow rates. The ozone concentration decreased with increasing organic matter and time. The amount of organic matter seems to be an important factor decreasing the dissolved ozone concentration in liquid. The ozone concentration was 0.07, 0.32, 1.28, and 2.3 mg/L when operating the plasma reactor for 30, 60, 180, and 300 s, respectively; i.e., the ozone concentration increased with the reactor operating time. The initial numbers of bacteria and Vibrio spp. were 800 and 480 CFU/mL, respectively. After operating the plasma reactor at a flow rate of 6 L/min for 30 s, no bacteria or Vibrio spp. were detected. The disinfection effect of this plasma reactor seems to be superior to that of a conventional ozone generator.
밸러스트수 처리를 위한 Plasma Gun의 전기적 특성과 오존 생성에 미치는 주요 운전변수들의 영향에 관해 실험실 규모 연구를 수행하였다. 방전개시전압보다 높은 전압이 인가되면 방전이 시작되고 오존이 생성되었으며 전압이 증가함에 따라 기체로 전달되는 에너지 및 오존 농도가 거의 선형적으로 증가하였다. 오존 생성 측면에서 최적의 에너지 효율성을 얻을 수 있는 전극간 거리가 존재하였으며 실험된 장치에서는 1.95 mm의 전극간 거리에서 최적 효율이 얻어졌다. 전기에너지 특성에 미치는 내부전극 재질의 영향은 무시할만한 수준이었으나 내부전극의 전기전도도와 열전도도 차이가 오존 생성에 큰 영향을 미치는 것으로 나타났다. 일정한 Plasma Gun 구조에서 오존 생성은 기체로 전달되는 에너지밀도에 의해 중요한 영향을 받는 것으로 나타났으며 유입되는 기체의 산소함량이 증가할수록 오존 생성이 증가하는 것으로 나타났다.
The objective of this study was to investigate the effects of pH and temperature on the formation of bromate, which is ozonation by-products, during ozonation.
In this experiment, the operating parameters including pH 3~10 and temperature 15~30℃ were studied. Through the study for the bromate formation, reaction rate constant, and ozonation effect index on pH and temperature, the results obtained are as follows. At the same initial pH condition, the increase of pH shown similar trends even if the reaction variables such as temperature and reaction time of ozonation were exchanged. As pH and temperature were increasing, the bromate concentration was increased but bromine(HOBr+OBr-) was decreased with increasing pH from 3 to 10. The activation energy(J/mol) for bromate formation decreased with increasing pH. The rate constants of bromate formation for the reaction of ozone and bromide, and ozone dosage coefficient(Ko) increased with temperature and pH. Ozonation effect index(OI) decreased with increasing temperature and pH.