Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
음향 도플러 유속계(Acoustic Doppler Current Profiler, ADCPs)는 하천의 유량측정에 널리 사용되고 있으나, 유량 측정성과의 불확도를 평가하는 방 법에 대하여 진행된 연구는 부족한 현실이며, 이는 실제 하천에서 유속 및 유량 등의 수리량을 조절하는 것이 현실적으로 불가능하여 ADCP의 불확도 요인 별 실험 및 분석이 어렵기 때문이다. 유량 및 수리량의 측정 불확도를 평가하기 위하여 과학 및 공학 분야에서는 다양한 연구들이 진행되어 왔으며, 그 중 국 제적으로 공인받고 있는 방법 중 하나가 GUM (Guide to the Expression of Uncertainty Measurement)이다. 본 연구에서는 GUM 표준안을 기반으로 ADCP의 유량 측정 불확도를 평가하기 위한 연구를 수행하였다. ADCP의 유량 측정 불확도 요인별 분석을 수행하기 위하여 유량 공급의 조절이 가능한 실 규모 수로를 보유하고 있는 하천실험센터에서 실험을 진행하였으며, ADCP의 측정 정확도에 영향을 미치는 수심, 측정 지점에서 하안까지의 거리, ADCP 의 잠김 깊이, 유속 오차, 측정 시간, 반복 횟수, 하상 조건 등에 대한 측정 정확도 평가 실험을 수행하였다. ADCP로 유량을 측정하는 방법은 지점측정방식 을 기반으로 유속-면적법을 통해 산정하는 방법과 일반적으로 사용되는 이동측정방식이 있으며, 본 연구에서는 ADCP의 지점측정방식을 통해 유량을 산정 하는 Section-by-Section 방법으로 산정된 유량의 불확도를 평가하였다. 모든 측정 결과는 요인별 불확도 평가를 수행하기 위하여 유속은 ADV, 수심은 광 파기로 측정된 결과와 비교하였다.
The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 m3/s, whereas the average ADC and Flowmate is 0.709 m3/s. Meanwhile, stream discharge has been calculated 0.709 m3/s through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers’ strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.
본 연구에서는 괴산댐 하류 달천에서 6가지 직접 유량 측정 방법-유속면적법, 봉부자법, ADCP이동측정법, ADCP정지 측정법, 전자파표면유속계, LSPIV-을 적용하고, 이를 댐 방류량 및 유속면적법과 비교함으로써 정확도를 상호 평가하였다. 이를 위해 2005년부터 2010년까지 실시된 총 39회의 유량측정결과가 분석되었다. 댐 방류량과의 비교 결과, 봉부자법을 제외한 나머지5가지 방법은 평균 6.2% 이내의 절대값오차를 나타냈다. 유속면적법과 다른