검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Wind tower structure has relatively simple shape compared to other structures, but due to its characteristics, various and irregular environmental loads are applied. These loads cause vibrations at tower, and can cause failure of the structure if over vibration occurs. Vibration occurred at structures is gradually exhausted by damping of the structures, and if high damping is ensured, the failure of the structure due to over vibration can be prevented. In this study, the vibration reduction effects are to be analyzed through FEM analysis by examining the top displacement, bottom moment, and bottom fatigue damage of the structure depending on damping ratio of the wind tower structure.
        3,000원
        2.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해상풍력발전의 건설이 여러 가지 환경 및 가설공법 등의 설치환경 등의 원인에 의하여 건설지점이 천해에서 심해로 이동하는 경향을 나타내고 있다. 이러한 경향 속에 해상풍력발전 지지구조물의 심해화에 따른 지지구조물에 대한 연구는 중요성이 더욱 증대될 것으로 판단된다. 본 연구에서는 기존의 Jacket 구조물에 대하여 Precast Concrete Block 및 Suction pile을 적용한 Jacket 구조물을 제안하고 이에 대하여 구조해석 및 안전성 평가를 실시하였다. 또한 제안된 구조물에 동조액체감쇠기를 적용하여 구조물 진동성능 향상을 도모하고자 하였다. 연구결과, 제안된 신형식 Jacket 구조물은 충분한 안전성을 가지고 있는 것으로 평가되었으며, 동조액체감쇠기를 적용하였을 경우, 약 5%의 진동저감 효과가 있는 것으로 검토되었다.
        4,000원
        3.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted , and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.
        4.
        2014.10 서비스 종료(열람 제한)
        Shows the problem of exposure to vibration generated from vehicle and train adjacent to the railway facilities are housing facilities. As a method for solving the problems caused by the vibration countermeasures have been provided various methods such as the vibration of the vibration trajectory, wave barriers wall, vibration isolation mat. Therefore, in the present study is to evaluate the vibration analysis by using vibration isolation mat for vibration reduction of housing facilities.
        5.
        2013.10 서비스 종료(열람 제한)
        Residential structures have been constructed near roads and railways in order to obtain an easy access to city and solve the limited land-use problem. But this trend has a weak point, such as noise and vibration due to the public transportation and it caused to make a civil petition. The goal of this study is to analyze the train-induced ground vibration effects on the structure and its reduction technique. Finally, this study can be helpful to provide a guideline to solve a civil petition and make a vibration reduction device.
        6.
        2013.03 KCI 등재 서비스 종료(열람 제한)
        사장교 케이블은 초기 큰 인장력으로 축강성이 매우 크지만, 횡방향 휨강성은 약하다. 풍하중이나 교통하중은 케이블을 심각하게 진동시켜 사장교의 사용성에 부정적 영향을 끼친다. 그러므로 장대교량에 감쇠장치를 설치하는 진동 저감 계획이 절실히 요구된다. 마찰댐퍼는 교통하중이나 풍하중과 같은 동적하중이 작용하는 케이블 진동에서 진폭과 지속시간을 대폭 감소시킬 수 있는 효과적인 장치임을 알 수 있다. 케이블 진동은 댐퍼제작방법과 설치위치 및 형상에 따라 효율이 달라질 수 있다. 그럼에도 불구하고 본 실험연구의 마찰댐퍼 설치전 후 제진성능효과 분석결과는 향후 사장케이블의 진동을 저감시키는 기본 자료로 활용할 수 있다.