A base isolation system is widely used to reduce seismic responses of low-rise buildings. This system cannot be effectively applied to high-rise buildings because the initial stiffness of the high-rise building with the base isolation system maintains almost the same as the building without the base isolation system to set the yield shear force of the base isolation system larger than the design wind load. To solve this problem, the mid-story isolation system was proposed and applied to many buildings. The mid-story isolation system has two major objectives; first to reduce peak story drift and second to reduce peak drift of the isolation story. Usually, these two objectives are in conflict. In this study, a hybrid mid-story isolation system for a tall building is proposed. A MR (magnetorheological) damper was used to develop the hybrid mid-story isolation system. An existing building with mid-story isolation system, that is “Shiodome Sumitomo Building” a high rise building having a large atrium in the lower levels, was used for control performance evaluation of the hybrid mid-story isolation system. Fuzzy logic controller and genetic algorithm were used to develop the control algorithm for the hybrid mid-story isolation system. It can be seen from analytical results that the hybrid mid-story isolation system can provide better control performance than the ordinary mid-story isolation system and the design process developed in this study is useful for preliminary design of the hybrid mid-story isolation system for a tall building.
In this study, the odor causing in the under-fired charbroiling restaurant was reported in literature investigation,pilot test and field experimental verification. The charbroiling restaurant causes odor complaints of Neighbors soefficient reduction method is requested. Acetaldehyde, ammonia, sulfur compound and the oil mist of white smokeare found to cause odor from the charbroiling restaurant. Pilot test results show that in the removal efficiency ofodor, Electrostatic Precipitation was 67.4%, absorption was 81.2%, adsorption was 74.2% and the ElectrostaticPrecipitation & Adsorption the hybrid system with 85.7% respectively. In the same condition of the hybrid system(Electrostatic Precipitation & Adsorption), the odor removal efficiency were higher when the design parameterssuch as the discharge voltage and current were high. The process efficiency were higher when as the implanterpole was cylindrical. However, the process efficiency rapidly reduced due to the contamination of the processcomponent or material, as the operating time of the equipment is increased. Therefore, fixed maintenance and repairof the equipment is found to be are very important, for long term operation. Therefore, as the experimental resultof this study, applying hybrid system removed odors caused in under-fired charbroiling restaurant which areunregulated, is more effective device that settle civil complaints and preserve environment.
An experimental real-time hybrid method, which implements the wind response control of a building structure with only a two-way TLMD, is proposed and verified through a shaking table test. The building structure is divided into the upper experimental TLMD and the lower numerical structural part. The shaking table vibrates the TLMD with the response calculated from the numerical substructure,which is subjected to the excitations of the measured interface control force at its top story and an wind-load input at its base. The results show that the conventional method can be replaced by the proposed methodology with a simple installation and accuracy for evaluating the control performance of a TLMD
본 논문에서는, 동조액체감쇠기(이하 TLD)만을 실험적 부분구조로 이용하여 TLD가 설치된 건축구조물의 지진 응답 제어효과를 평가하기 위한 실시간 하이브리드 실험법을 제안하고 진동대 실험을 통해 실험적으로 규명한다. 제안된 실험법에서, TLD가 설치된 전체구조물은 상부의 TLD와 하부의 구조물 부분으로 각각 실험적 그리고 수치해석적 부분구조로 나누어진다. 이때 부분구조 사이의 경계면에서 작용하는 하중 또는, TLD에 의한 제어력은 진동대에 설치된 전단형 로드셀에 의해 계측되며 진동대는, 계측된 경계면에서의 제어력이 상부에 작용하고 또한 동시에 기초에 지진하중이 작용하는 수치해석적 부분구조로부터 계산된 응답으로, 상부에 설치된 TLD를 가진하게 된다. 제안된 실험법에 의한 결과와 TLD와 건물모델 모두를 제작하여 실험하는 기존의 방법에 의한 실험 결과들은 서로 잘 일치하며, 이로써 본 논문에서 제안된 실험법을 이용하여 TLD의 제어성능을 손쉽게 평가 할 수 있음을 알 수 있다.
본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물에 대하여 진동대 실험을 수행하였다. 본 연구에서 사용된 하이브리드 면진장치는 네 개의 FPS와 한 개의 MR 감쇠기로 구성하였다. 다양한 크기 및 특성을 가진 지진하중을 하이브리드 면진장치가 설치된 구조물에 가하여 진동제어 성능을 평가하였다. 본 연구에는 준능동 MR 감쇠기의 저항력을 효과적으로 조절하기 위하여 퍼지제어기를 사용하였고 구조물에 부착된 계측기를 통하여 변위 및 가속도를 피드백으로 이용한다. 수동 및 준능동 제어기법을 사용하여 얻은 구조물의 응답을 서로 비교하였고 그 결과 FPS와 MR 감쇠기의 조합으로 다양한 특성의 하중을 받는 구조물의 진동제어를 효과적으로 수행할 수 있음을 알 수 있다.
Coal-fired thermal power generation was a very important power source in Korea. Therefore improvement of seismic reliability of the coal-fired thermal power plants is required, because occurrence of very large earthquakes is expected in Korea. Boilers of coal-fired power plants are usually suspended from the upper end of support structures in order to allow thermal expansion of the boilers, so boilers easily sway during earthquakes. In order to suppress the vibration, stoppers made of steel are generally installed between boilers and their support structures. Although stoppers made of steel are effective for vibration suppression, further countermeasure for earthquakes having long duration and many after shocks is required. This study has developed a hybrid damper for vibration and seismic control of coal-fired power plant boiler. The hybrid damper consists of an oil damper and a friction damper connected in series.
본 논문은 하이브리드 전기 추진 시스템의 전력 제어에 관한 연구를 수행하였다. 하이브리드 전기 추진 시스템은 기본적으로 발전기와 축전지 전원을 이용하여 선박을 추진하는 시스템이다. 하이브리드 추진 시스템은 공급되는 전력을 최소화하기 위한 제어 알고리즘으로 동작한다. 본 논문에서는 하이브리드 전기 추진 시스템의 효율을 증가시키기 위한 축전지 충전 알고리즘을 제안한다. 실험을 통하여 제어 알고리즘이 하이브리드 전기 추진 시스템에서 정상적으로 동작하는 것을 알 수 있었다.
본 연구는 지진동을 받는 구조물의 응답을 제어하기 위한 하이브리드 LQG 기법의 효용성을 조사하는 것이 목적이다. 입력 기진력은 엘센트로 지진이며 지반 가속도을 적절히 조절하여 구조물이 탄성 범위내에서 거동하도록 하였다. 수동 제어 장치로서 최상층에 설계된 TMD는 LQG 제어 알고리즘에 의해 통제되며 능동 제어기와 함께 하이브리드 제어 시스템을 이룬다. 이 기법을 통해 제어된 변위 응답을 비교한 결과 순수하게 능동 제어를 한 경우에 비해 훨씬 작은 크기의 입력으로도 변위를 제어할 수 있었으며 센서의 위치는 최상층에 부착하는 것이 가장 효과적인 것으로 나타났다.