        검색결과 13

        1.
        2023.05 구독 인증기관·개인회원 무료
        The radiolytic decomposition of oxalic acid was investigated using gamma irradiation for decontamination of nuclear power systems. The study used high-purity analytical grade chemicals, with initial concentrations of oxalic acid prepared at 1, 2, 5, and 10 mM, and the initial pH was adjusted to 2-3 at each test condition. Gamma irradiation was performed using a high-level Co-60 source, and absorbed doses were 5, 10, 20, 30, and 50 kGy. The results showed that the efficiency of gamma irradiation decreased with longer gamma exposure time, and the G-value increased with the initial concentration of oxalic acid. Interestingly, the G-value decreased with accumulated radiation dose, but the removal increased. The dose constant ranged from 0.1695 to 0.0536 kGy-1 at different initial concentrations, and the G-value was inversely proportional to the dose constant. The study concluded that oxalic acid was successfully degraded by gamma irradiation, and 92% removal was obtained at the initial concentration of 10 mM. The mineralization of oxalic acid at higher concentrations was more difficult due to the great number of generated intermediates.
        3.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        국내 남성에게서 지속적으로 발생하는 전립선암을 대상으로, 근접치료 시 금 나노입자 밀도에 따른 흡수 선량을 평가하고자 하였다. 흡수선량 평가는 몬테카를로 시뮬레이션을 이용한 MCNPX 프로그램을 이용하였다. 선원은 일시적 삽입선원 192Ir과 영구적 삽입선원 103Pd을 이용하였으며, 금 나노입자의 밀도는 0 mg, 7 mg, 18 mg, 30 mg으로 하였다. 그 결과 표적장기인 전립선은 192Ir이 2.95E-14 Gy/e에서 4.42E-14 Gy/e로 밀도에 비례해서 증가하였으며, 103Pd도 동일한 경향성을 보였다. 또한 주변장기에 대한 선량은 밀도에 반비례하여 감소하는 것으로 나타났다. 따라서 근접치료 시 나노입자의 사용은 치료가능비를 상승시킬 수 있을 것으로 판단된다.
        4.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        방사선치료 기법의 발전으로 치료가 더욱 정밀해졌음에도 불구하고 치료 부위 외에도 방사선에 의해 피폭되는 것은 피할 수 없다. 이에 본 연구에서는 유방암의 방사선치료 시 치료 반대편 유방의 bolus 두께에 따른 흡수선량을 평가하고 선량 저감 효과에 대해 분석하고자 하였다. 실험 및 방법으로 Rando phantom을 대상으로 VMAT 치료방법을 이용하여 실험을 진행하였다. 치료 반대편 유방에 A, B, C, D, E의 5개 지점을 선정하여 bolus를 사용하지 않았을 때와 5, 10, 15, 20 ㎜ 의 bolus를 사용하였을 때의 선량을 유리선량계를 사용해 평가하였다. 그 결과, 치료지점과 가장 가까운 지점에서 높은 흡수선량이 측정되었으며 치료지점과 가장 먼 B 지점에서는 가장 낮게 측정되었다. 평균 흡수선량은 bolus를 사용하지 않았을 때 8.61 cGy 그리고 두께에 따라 8.10, 7.94, 8.06, 8.10 cGy로 나타났다. 연구 결과 선량 저감 효과를 확인할 수 있었으며, 본 연구를 바탕으로 적절한 bolus 두께를 설정하여 정상조직의 선량 저감화를 위해 노력해야 할 것이다.
        5.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        방사선 치료시 산란성 등의 피부영향을 피할 수 없으며 내부의 정상장기의 피폭은 피할 수 없다. 방사선 치료의 역사는 정상조직의 흡수선량 감소를 위한 역사라고 해도 과언이 아니다. 특히, 왼쪽 유방암의 방사선 치료시 내부 인접 장기로는 정상유방조직, 심장과 폐를 대표로 들 수 있는데 심장에 발생할 수 있는 부작용은 심정지, 심근경색 등이 있다. 본 논문에서는 왼쪽 유방암 환자의 방사선 치료시 호흡조절기법을 사용한 것과 일반 방사선치료계획을 시행하는 것 사이에 심장의 체적과 선량의 변화를 관찰하여 호흡으로 인해 발생하는 심장의 체적과 선량을 알아보았다. 연구결과 4차원 컴퓨터 단층촬영영상을 기준으로 심장의 체적은 평균 12.8±8.7 cc의 차이가 나타났으며 이에 대해 선량은 평균 17.3±12.1 cGy의 차이를 보였다. 이러한 체적과 선량의 차이는 향후 방사선 치료시 부작용을 발생시킬 수 있는 우려가 있으므로 호흡조절기법을 활용하여 심장의 정확한 위치를 기반으로 방사선 치료계획을 수립하여야 할 것이다.
        6.
        2018.04 KCI 등재 서비스 종료(열람 제한)
        국내 남성에게서 많이 발생하는 전립선암을 대상으로, 근접치료 시 나노입자 사용에 따른 선량을 평가하여 기초자료를 제시하고자 하였다. 선량평가는 몬테카를로 시뮬레이션 기법인 MCNPX 프로그램을 이용하였다. 선원은 국내 HDR장비에 다용하는 192Ir으로 선정하고 나노입자는 금, 가돌리늄, 산화철, 요오드를 사용하였다. 그 결과 표적장기인 전립선은 나노입자를 사용 시, 사용하지 않은 경우에 비해 모두 흡수선량이 높게 나타났다. 특히 금 나노입자가 3.13E-03 J/kg·e의 값으로 가장 높았다. 주변장기 및 주변인에 대한 선량은 나노입자 사용에 따른 차이가 크지 않은 것으로 나타났다. 나노입자 사용은 치료가능비를 상승시켜 치료효율을 증가시킬 수 있을 것으로 판단된다.
        7.
        2018.02 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 OSL 도트 선량계의 교정인자, 흡수선량 선형성, 피크전압 선형성, 각도 변화에 의한 흡수선량 변화를 측정하고 분석했다. 의료용 X 선발생 장치를 사용하여 조사에 노출 선량 보정 계수, 흡수선량 선형성, 피크 전압 선형성은 모두 IEC-62387-1 (2007) 기준을 만족하였다. 기준 방사선 노출과 관련하여 0도, 30도 및 60도에서 선량계 방향에 대한 기준은 -29 % (± 30 °) 및 + 67 % (± 60 °)이었다. 30도에서 측정 된 값은 기준보다 -8 % 낮고 60도에서 기준보다 -18 % 낮게 나타났다. 그러므로 OSL 도트 선량계 사용 시 방향에 따른 영향을 보정하여야 한다.
        8.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        The cone beam computed tomography(CBCT) which can acquire 3-dimensions images is widely used for confirmation of patient position before radiation therapy. In this study, through the simulation using the Monte Carlo technique, we will analyze the exposure dose by cone beam computed tomography and present the standardized data. For the experiment, MCNPX(ver. 2.5.0) was used and the photon beam spectrum was analyzed after Cone beam was simulated. As a result of analyzing the photon beam spectrum, the average energy ranged from 25.7 to 37.6 keV at the tube voltage of 80 ∼ 120 kVp and the characteristic X-ray energy was 9, 60, 68 and 70 keV. As a result of using the water phantom, the percentage depth dose was measured, and the maximum dose appeared on the surface and decreased with depth. The absorbed dose also decreased as the depth increased. The absorbed dose of the whole phantom was 9.7 ~ 18.7 mGy. This is a dose which accounts for 0.2% of about 10 Gy, which is generally used for radiation therapy per week, which is not expected to have a significant effect on the treatment effect. However, it should not be overlooked even if it is small compared with prescription dose
        9.
        2016.10 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 움직이는 타깃을 대상으로 처방선량과 치료기법에 따른 흡수선량을 유리선량계를 이용하여 평가하였다. 타깃의 움직임에 따라 조사야에서 벗어나는 정도에 따른 선량을 MCNPX를 이용하여 모의모사하였으며 그 결과 조사야에서 이격하는 거리에 비례하여 감소하는 것으로 나타났다. 처방선량에 따른 흡수선량의 결과는 3D CRT의 경우 저선량에서 IMRT보다 흡수선량이 높은 것으로 나타났으며, 대선량에서는 IMRT가 더 높은 비율을 보였다. 치료기법에 따른 결과는 3D CRT가 가장 우수한 것으로 나타났으며, IMRT의 sliding window방식이 가장 낮은 것으로 나타났다. 본 연구를 통하여 3D CRT가 움직이는 타깃에 가장 높은 선량을 조사할 수 있는 기법으로 평가되었다. 하지만 정상조직의 보호효과와 환자의 상태 등을 고려한 적절한 치료기법의 선택으로 치료효과를 높일 수 있는 노력이 필요할 것이다.
        10.
        2016.08 KCI 등재 서비스 종료(열람 제한)
        본 연구는 IEC에서 제시하는 영상품질을 평가하는 조건으로는 임상적인 환경에서 디지털 방사선영상시 스템(Digital Radiography System)에서의 검출기에 대한 영상품질평가를 시행하기에는 환경적인 제한점이 있 기에 IEC에서 제시하는 조건과 임상검사조건을 조합한 각각의 선질에 대하여 영상품질평가를 시행한 연구 입니다. 첫째, 네 가지 선질을 사용하여 MTF, NPS 영상품질평가를 하였으며, MCNPX 시뮬레이션을 이용 하여 선질들에 대한 스펙트럼을 분석하여 입자 플루언스를 산정한 후 최종적으로 DQE 영상품질평가를 하 였다. 둘째, 네 가지 선질들의 MCNPX 시뮬레이션을 이용하여 방사선속 밀도와 에너지, 물질의 질량에너지 흡수계수를 이용하여 전자 1 개당 공기, 물, 근육, 뼈에 대한 흡수선량률을 평가하였다. 영상품질을 평가한 결과, 네 가지 선질들의 MTF는 1.13 ∼ 2.91 lp/mm 공간주파수를 나타내어 일반 X선 촬영의 진단 주파수 영역인 1.0 ∼ 3.0 lp/mm를 만족하였다. NPS는 부가필터를 사용하면, 공간 주파수가 0.5 lp/mm 기준으로 NP S가 증가하다가 이후, 감소하는 경향성을 나타내었다. 부가필터 미사용하면, 공간주파수가 0.5 lp/mm 기준 으로 NPS가 감소하다가 이후, 일정한 NPS 결과 값을 나타내었다. DQE는 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm에서 공간주파수 1.5 lp/mm 기준으로 일정한 값을 나타내다가 이후, 감소하는 경향성 을 나타내었다. 나머지 선질들은 공간주파수가 증가함에 따라 감소하는 경향성을 나타내었다. 흡수선량 평가 결과는 공기< 물 < 근육 < 뼈 순서로 흡수선량이 증가함을 나타내었다. 본 연구결과를 바탕으로 다양한 임 상환경에서 디지털 방사선영상시스템의 영상품질평가 방법을 제시할 수 있는 기초자료로 제공하고자 한다.
        11.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        본 연구는 방사선 치료 영역의 선량 측정을 위하여 상용화된 열형광선량계의 가열 온도에 따른 형광 곡선의 특성을 분석하였다. 본 연구에 사용된 열형광선량계는 LiF:Mg Ti, LiF:Mg Cu P, CaF2:Dy, CaF2:Mn(Thermo Fisher Scientific Inc., USA)이었다. 선원과 고체 팬텀 표면(RW3 slab, IBA Dosimetry, Germany)간 거리를 100cm로 하여 기준점 깊이에서 6MV, 15MV X선과 6MeV, 12MeV 전자선을 각각 100MU 조사하였다. 방사선 조사 후 열형광 판독기(Hashaw 3500, Thermo Fisher Scientific Inc., USA)를 사용하여 50°C에서 260°C까지 15°C/sec의 가온율로 가열하여 형광 곡선을 분석하였다. 트랩 준위에 포획된 전자가 정공과 결합하면서 빛을 방출하는 형광 피크(glow peak)는 2개 또는 3개의 피크가 나타났으며 방사선 조사 후 TLD의 온도를 일정하게 증가시켰을 때 최대 형광 피크를 나타내는 형광 온도의 경우 각각의 에너지에 따라 LiF:Mg·Ti 선량계는 185.5±1.3°C, LiF:Mg·Cu·P 선량계는 135.0±5.1°C, CaF2:Dy 선량계는 144.0±1.6°C, CaF2:Mn 선량계는 294.3±3.8°C 근처에서 최대 형광 피크를 각각 나타났다. 방사선조사 후 포획 전자의 형광 방출 확률은 가열 온도에 의존하게 되므로 방사선 치료 영역의 선량 측정에서 방사선 조사 후 열형광선량계에 일정한 가온율을 적용함으로써 고유한 물리적 특성에 따른 측정 정확도를 향상시킬 수 있을 것으로 판단되었다.
        12.
        2011.12 KCI 등재 서비스 종료(열람 제한)
        Geant4와 DICOM 파일의 연동을 이용한 몬테카를로 시뮬레이션을 통해 실제 환자의 흡수선량을 산출하는 새로운 방법을 제시하고, Geant4 계산코드의 검증을 위해 MOSFET 선량계를 이용하여 PMMA 모의 팬텀 깊이에 따른 중심에 서의 흡수선량 실측값과 Geant4 시뮬레이션 결과값을 비교하였다. PMMA slab의 불완전한 압착으로 인해 발생한 불 균등한 간격의 공기층이 존재하지 않은 부분에서는 X선 조사야 15 × 15 cm2 와 20 × 20 cm2 에서 각각 0.46 ± 4.69% 와 -0.75 ± 5.19%로 나타났다. PMMA 모의 팬텀의 불완전한 압착에 의해 나타난 오차를 제외하면 Geant4와 DICOM 파일의 연동을 통한 몬테카를로 시뮬레이션에 의한 계산값이 잘 일치함을 알 수 있다.
        13.
        2011.12 KCI 등재 서비스 종료(열람 제한)
        치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영 에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용 한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여 야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.