검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performancecentered design.
        4,000원
        2.
        2015.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        HPGe 검출기를 이용하여 밀도가 다양한 환경시료에 대한 정밀 분석시 정확한 분석을 위해서는 밀도보정인자가 필요하다. 밀도에 대한 보정인자를 구하기 위해서 본 연구에서는 몬테카를로 코드인 MCNPX 코드를 사용하여 크리스털의 높이, 지름 및 코어의 크기와 같은 특성이 다른 세 대의 p-type HPGe 검출기를 모사하고 밀도 1 g/cm3의 교정용 표준시료를 이용하여 모 델링을 검증하였다. 검증을 통하여 모델링을 확정한 후 0.3, 0.6, 0.9, 1.0, 1.2, 1.5 g/cm3 밀도를 가진 샘플에 대한 효율을 시 뮬레이션하고 밀도보정인자를 도출하였다. 도출된 각 검출기에 대한 밀도보정인자를 비교하였을 때 전 에너지 범위에서 그 차이가 거의 없음을 확인하였으며 이는 검출기의 크리스털과 같은 주요 특성에 대해 밀도보정인자가 독립적임을 의미한다.
        4,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% (62.3 μGy vs. 125.1 μGy). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from 320.8 μGy to 284.7 μGy (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.
        4,000원
        4.
        2011.06 구독 인증기관 무료, 개인회원 유료
        본 논문은 독거노인 또는 부정맥 환자의 24시간 응급감시 모니터링을 위해 광소자를 이용한 독거노인 위험감지형 맥박센서를 설계했다. 투과형의 광소자를 사용한 맥박 측정 센서는 상용 기술이지만, 이것은 의료 기관에서 환자나 환자 진료 모니터링을 위한 일회성 측정 방법이다. 때문에 일상생활에서 무구속의 지속적인 측정이 가능한 센서 개발이 필요하며, 또한 내구성과 편의성, 유동성에 대한 신뢰성과 안정성을 유지해야한다. 이러한 조건에서 우리는 손목시계 타입의 독거노인 위험감지형 맥박 센서를 설계하고, 실험 결과에서 그 가능성을 확인했다.
        4,000원
        6.
        2012.01 KCI 등재 서비스 종료(열람 제한)
        최근 디지털 방사선 영상획득을 위한 평판형 X선 검출기에 이용되는 광도전체(a-Se, HgI2, PbO, CdTe, PbI2 등)에 대한 관심이 증대되고 있다. 본 연구에서는 입자침전법 적용이 가능한 광도전 물질을 이용하여 X선 영상 검출기 적용을 위한 필름층을 제작하여 평가하였다. 먼저, X선 영상에서 일반적으로 사용되는 에너지대역인 70 kVp 의 연속 X선에 대한 필름 두께별 양자효율을 몬테카를로 시뮬레이션을 통해 조사하였다. 평가결과, 현재 상용화된 500 μm 두께의 a-Se 필름에 대한 양자효율인 64 %와 유사한 HgI2의 필름의 두께는 180 μm 정도였으며, 240 μm 두께에서 74 %의높은 양자효율을 보였다. 입자침전법을 이용하여 제작된 239 μm 필름에 대한 전기적 측정결과, 10 pA/mm2 이하의 매우 낮은 암전류를 보였으며, X선 민감도는 1 V/μm의 인가전압에서 19.8 mC/mR-sec의 높은 감도를 보였다. 영상의대조도에 영향을 미치는 신호 대 잡음비 평가결과 0.8 V/μm의 낮은 동작전압에서 3,125의 높은 값을 보였으며, 전기장의 세기가 높아질수록 암전류의 급격한 증가에 의해 SNR 값이 지수적으로 감소하였다. 이러한 결과는 종래의 a-Se을 이용하는 평판형 검출기를 입자 침전법으로 제작 가능한 필름으로 대체하여 저가형 고성능 영상검출기 개발이 가능할 것으로 기대된다.