In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.
PURPOSES : Sprinkler facilities play a crucial role in extinguishing fires in the early stages of a building blaze. Data indicate that more than 96% of fires are suppressed by sprinklers before growing out of control. However, corrosion and pitting of the sprinkler piping can reduce system performance as facilities age. The purpose of this study is to develop an eco-friendly water-soluble corrosion inhibitor to improve the reliability and longevity of sprinkler piping. METHODS : This study compared and analyzed silicate-based sprinkler piping shrinkage agents as corrosion inhibitor against existing commercial options. Tests were conducted to evaluate reactivity with fire extinguishing water, including electrolyzed reduced water and normal water. The anticorrosive performance of the silicate-based corrosion inhibitor was evaluated under various conditions to establish suitability before potential development or commercialization. RESULTS : The new corrosion inhibitor demonstrated eco-friendly performance. In testing, none of the primary four hazardous substances that pose the most risk of harm to the human body (specifically, arsenic (As), lead (Pb), cadmium (Cd), and mercury (Hg)) were detected. The inhibitor effectively reduced corrosion of carbon steel (SPP), with weight loss rates averaging 0.12% and not exceeding 0.27%. For copper (CDA 110) weight loss rates were up to 0.03%. Testing under constant temperature and humidity conditions show that the inhibitor kept weight loss was below 0.002 g, with no significant numerical value for the weight loss rate. Overall, the results indicate the potential for an environmentally-safe corrosion inhibitor. CONCLUSIONS : The optimal silicate-based sprinkler system can provide real-time sensor information such as oxygen saturation, pH concentration, and total dissolved solids (TDS). These metrics are closely related to the aging process. By linking this system with an aging monitoring solution, maintenance costs and safety could be improved over the lifespan of the sprinkler system. The sensors and monitoring capabilities are expected to enhance maintenance efficiency and equipment reliability.
The BIG11003 strain was isolated as protein-degrading actinomycetes from cucumber farm. The effect of plant natural resources (Azadirachta indica L and Sophora angustifolia) of juveniles and the hatching of eggs of Meloidogyne sp. were examined the laboratory. The nematicides (fosthiazate), actinomycetes protease and S. angustifolia extract resulted in 45.6, 46.6 and 51.23% mortality of J2 of M. incognita. The nematicides (fosthiazate), A. indica L and S. angustifolia extract resulted in 2.06, 3.96 and 6.22% hatch of egg of M. incognita. Antinematode activity test had done after the formulation of liquid (Nemastar) with mixture of additives and inerts into selected highly active natural material and actinomycetes protease. In pot and field experiments, the nemastar had good control efficacy against plant root-knot nematodes. Anti-nematode activity of strain BIG11003 from phylogentic analysis based on 16S rDNA sequences, it is suggested the Streptomyces koyangensis.