검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        2.
        2023.05 구독 인증기관·개인회원 무료
        The hydride reorientation (HR) of the post-irradiated nuclear fuel cladding after use affects the integrity of the spent nuclear fuel. During the dry storage process, which is an intermediate storage method, it was found that the hydride in the circumferential direction is rearranged into radial hydride, and this is believed to be due to factors such as hoop stress, peak temperature, accumulated hydrogen concentration, and cooling rate during the storage period. f(HR) = f(Tmax) + f(σH) + f(CH) + f(△T) + f(10Cy) + f(cooling rate) + ...... To simulate long-term dry storage of spent nuclear fuel, the hydride reorientation behavior was evaluated using unirradiated Zircaloy-4 (CWSRA) cladding with hydrogen charged under various hoop stresses (70, 80, 90, and 110 MPa) at long-term cooling periods (3, 6, and 12 months). Test results showed that as the cooling time increased, the sample with 90 MPa hoop stress at a maximum temperature of 400°C approached the ductility recommendation limit of 2%. In a 90 MPa hoop stress specimen with 3 months cooling period at peak temperature of 400°C, the offset strain was 4.24% at room temperature RCT, while it showed the result of 2.86% for the cooling period of 12 months. On the other hand, the specimen with hoop stress of 110 MPa and cooling period of 12 months showed result of 1.4%. The test results need to take into account errors in hydrogen charging and hydrogen analysis, and it is necessary to consider reproducibility through repeated tests. These results indicate the need for continued attention to the evaluation of the effects of hydride reorientation due to long-term cooling in the context of the integrity of spent fuel.
        3.
        2022.05 구독 인증기관·개인회원 무료
        A long-term cooling effect on hydride reorientation of a cladding tube can affect the integrity of spent nuclear fuel transportation and long-term storage. In this study, experimental setup for investigating the degree of radial reorientation of hydrides in the circumferential direction during the long-term cooling was established. The experimental setup was designed to be simplified since the long-term evaluation requires a long term period such as 12, 18 and 24 months when the cladding tube specimen is gradually cooled down from 400°C to 100°C. For the test, hydrogen-charged specimens of 100 ppm, 200 ppm, and 500 ppm were prepared. The specimen was sealed with fixtures and check valve, and was pressurized up to 90 Mpa. To heat the specimen, a box-type furnace was used while the temperature of the specimen was measured from thermocouples attached to the specimen. After the heat treatment, the long-term cooling was performed by developing temperature control program to investigate several cooling rate conditions of the specimen. As a reference case, microstructure and brittle property of the hydrogen-charged specimens of 100 ppm, 200 ppm, and 500 ppm without the long-term cooling was observed. In the case of the hydrogen content, it was uniformly distributed in circumferential direction although it was non-uniform in the axial direction. In the case of the brittle property, a compression test was performed. For the future work, the microstructure and brittle property of the hydrogencharged specimens after the several long-cooling conditions were investigated. Then, the degree of radial reorientation of hydrides in the circumferential direction during the long-term cooling was studied.
        6.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, underground pipes are utilized in various fields of applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. Most of pipes are installed for long-term purposes and they should be safely installed in consideration of installation conditions because there are unexpected various terrestrial loading conditions. In this paper, we present the result of investigation pertaining to the structural behavior of glass fiber reinforced thermosetting polymer plastic (GFRP) flexible pipes buried underground. The mechanical properties of the GFRP flexible pipes produced in the domestic manufacturer are determined and the results are reported in this paper. In addition, ring deflection is measured by the field tests and the finite element analysis (FEA) is also conducted to simulate the structural behavior of GFRP pipes buried underground. From the field test results, we predicted long-term, up to 50 years, ring deflection of GFRP pipes buried underground based on the method suggested by the existing literature. It was found that the GFRP flexible pipe to be used for cooling water intake system in the nuclear power plant is appropriate because 5% ring deflection limitation for 50 years could be satisfied.
        4,000원