The single layer latticed domes have attracted many designers and researchers's attention all of the world, because these structures as spatial structure are of great advantage in not only mechanical rationality but also function, fabrication, construction and economic aspect. But single layer latticed domes are apt to occur the unstable phenomena that are called "buckling" because of the lack of strength of members, instability of structural shape, etc. In the case of latticed dome, there are several types of buckling mode such as overall buckling, local buckling, and member buckling according to the shape of dome, section type of member, the size of member, junction's condition of member and so on. There are many methods to increase the buckling strength of the single layer latticed dome, that is, with the change of geometrical shape of dome, the reinforcement of buckled member, etc. Therefore, the purpose of this study is to verify the reinforcement effect of buckled member when designers reinforce the buckled member to increase the buckling strength of single layer latticed dome with 3-way grid.
This study investigated characteristics of buckling load and effective buckling length by member rigidity of dome-typed space frame which was sensitive to initial conditions. A critical point and a buckling load were computed by analyzing the eigenvalues and determinants of the tangential stiffness matrix. The hexagonal pyramid model and star dome were selected for the case study in order to examine the nodal buckling and member buckling in accordance with member rigidity. From the numerical results, an effective buckling length factor of adopted models was bigger than that of Euler buckling for the case of fixed boundary. These numerical models indicated that the influence of nodal buckling was greater than that of member buckling as member rigidity was higher. Besides, there was a tendency that the bifurcation appeared on the equilibrium path before limit point in the member buckling model.
본 연구의 목적은 볼접합부를 갖는 원형강관의 좌굴실험 결과를 토대로 하여 국내외 압축재 설계규준과 비교 평가함으로써 부재의 좌굴내력 및 좌굴길이 계수의 안전성과 합리성을 조사하는 것이다. 좌굴성능 평가를 위해 선정된 원형강관은 ∅48.6×2.8t와 ∅60.5×3.2t 및 ∅ 76.3×3.2t이다. 국내외 압축재 설계를 위해 우리나라의 하중저항계수 설계법(LRFD), 일본의 한계상태 설계법(LSD) 및 영국의 BS5950 규준을 적용하였다. 본 연구에서는 선행연구의 실험결과와 국내외 설계규준과의 좌굴성능을 비교 분석하였다. 그 결과를 요약해 보면 다음과 같다. 각 국의 압축재 설계규준에서 부재의 전체길이를 좌굴길이로 적용한 결과 실험에 의한 좌굴내력의 64%∽89% 정도로 나타났다. 따라서 안전을 위해 현재 설계 규준식에 준하여 부재설계를 수행하는 것이 바람직하다고 판단되었다. 실험결과 측정된 좌굴내력은 우리나라, 일본 및 영국의 압축재 설계규준에서 좌굴길이를 순수 원형강관만으로 고려한 좌굴내력 값에 비해 1.02배∽1.43배 높은 것으로 나타났다. 따라서 스페이스 프 레임 구조물 설계에 있어 개별부재 좌굴내력은 절점 간 길이가 아닌 순수 원형강관의 길이로 좌굴계수를 고려할 필요가 있을 것으로 보여진다.
The reinforcement effect of buckling resistance steel damper on member with two-column and beam is evaluated by investigating the relationship of lateral load and displacement
The reinforcement effect of buckling resistance steel damper on member with two-column and beam is evaluated by investigating the relationship of lateral load and displacement.