In the current research, a seismic ceiling system as one of non-structural elements in buildings has been developed by applying newly designed vertical hanger clips combined with M-bar channel clips. In order to evaluate the seismic performance of the developed system, full-scale shaking table tests of one story frame structure with the conventional ceiling system or the developed seismic ceiling system were performed with time-history responses under earthquake loads. The developed system was also evaluated by the time-history dynamic analysis. From seismic test and analysis, it was shown that the developed seismic ceiling system could give improved seismic performances to minimize displacements and damages of ceiling systems as well as enhance seismic safety of the ceiling system.
이 연구에서는 실제 단면크기를 갖는 철근 콘크리트 기둥의 내진보강을 위한 단면확대 공법에서 효율적인 띠철근 배근 방법을 평가하였다. 비내진 상세를 갖는 기존 기둥의 단면크기는 450 × 450 mm이며, 단면확대 보강기둥의 단면크기는 750 × 750 mm이다. 확대 단면에서의 폐쇄형 외부 띠철근 배근을 위해 ㄷ-형 띠철근의 겹칩이음 및 철근 선조립 공법을 제시하였으며, 보조 띠철근으로서 크로스타이 앵커링 시공 및 V-타이를 고려하였다. 실험 결과, 무보강 기둥 및 ㄷ-형 외부 띠철근을 적용한 보강기둥의 압축내력은 ACI 318-14의 공칭내력과 비슷한 수준인 반면 철근 선조립 공법을 적용한 기둥의 압축내력은 ACI 318-14의 공칭내력 대비 1.25배 높았다. 특히 철근 선조립 공법을 적용한 보강 기둥의 압축 연성비는 크기효과에 의한 연성비 저하 가능성에도 불구하고 기존 기둥에 비해 139% 증가하였다. 즉, 제시된 철근 선조립 공법은 단면확대 보강기둥에서 주철근 조기 좌굴방지 및 콘크리트 구속에 효율적인 띠철근 상세로 평가될 수 있었다.
The techniques for seismic design and seismic reinforcement of structural members in Korea have beendeveloped in a wide variety of ways, but research and technology on seismic retrofitting methods of nonstructural materials are very inadequate. In this study, we analyze ceiling system products of Japan which have seismic performance as a basic study on the development of non-structural ceiling system.
This research is an application of SHCC (Strain harding Cementitious Composite) in concrete shear wall system in order to improve the structural performance of conventional shear walls. Based on experimental loading results, it was observed that the developed SHCC shear walls showed improved strength as well as enhancements in controlling of bending and shear cracks.
This study evaluated displacement of ceiling system under lastic dynamic load. Main parameters are change of stiffness at connections of bolt and C channel ranged between 0.1~2.0 kN/mm. Program for elastic dynamic anaysis is the MIDAS ZEN. Analysis results showed that connections between bolt and C channel was effective on decreasing of displacement of ceiling system.
The reinforcement effect of buckling resistance steel damper on member with two-column and beam is evaluated by investigating the relationship of lateral load and displacement
The reinforcement effect of buckling resistance steel damper on member with two-column and beam is evaluated by investigating the relationship of lateral load and displacement.
This study tested two RC columns with 500 mm square section under the constant axial loading and cyclic lateral loadings to examine the effectiveness of supplementary V-ties in enhancing the ductility of columns. The displacement ductility ratio of V-tie column was 1.5 times higher than that of the companion cross-tie columns.
The four buckling resistance steel dampers were tested under cyclic lateral load to investigate the relationship of lateral load and displacement. The main variables are the existence of cover plate for preventing from buckling of out-of-plane and thickness of sim plate with 3.2 mm, 4.5 mm and 7.0 mm. The test showed that steel damper with cover plate had the wider area of its hysteresis loop than that of without.
In bridge lifting apparatus by using the existing pressure control, unequal lifting inevitably occur due to non-uniform load of the upper structure. In order to solve this problem safety of bridge lifting apparatus using flow control system was evaluated. As a result, the load of each supports for bridge upper structure is measured at the range of 1,098 ~ 2,362 kN and lifting displacement uncertainty was within 0.5 mm observing not any cracks.
본 연구는 폴리머 기반 보수모르타르에 미분쇄된 플라이애시 치환율의 영향을 평가하였다. 주요변수는 양생온도와 미분쇄된 플라이애시의 치환율이다. 양생온도는 40℃, 20℃ 및 5℃로, 미분쇄된 플라이애시 치환율은 결합재 대비 0~35%로 변화하였다. 굳지 않은 모르타르에서는 플로우를, 굳은 모르타르에서는 재령별 압축강도, 응력-변형률 관계 및 탄성계수, 파괴계수를 측정하고, 주사전자현미경 및 엑스선회절기 분석을 수행하였다. 실험결과 보수모르타르의 플로우, 탄성계수 및 파괴계수는 미분쇄된 플라이애시 치환율 20~30%에서 가장 높은 성능을 발휘하였다. 또한 재령별 압축강도는 미분쇄된 플라이애시 치환율과 양생온도에 현저한 영향을 받았는데, 미분쇄된 플라이애시 치환율 20%에서 초기강도 발현율이 가장 높았다. ACI 209에서 제시하고 있는 콘크리트 재령별 압축강도예측모델에서 초기 및 장기재령 강도발현 계수는 미분쇄된 플라이애시 치환율과 양생온도의 함수로 일반화할 수 있었다. 미분쇄된 플라이애시가 첨가된 페이스트는 수화생성물을 나타내는 피크(peak)의 수와 강도(intensity)가 증가되고 플라이애시 입자주변에 CSH 겔이 형성되었다.
본 연구에서는 경량 콘크리트에 대한 361개, 보통중량 콘크리트에 대한 1,335개 및 고중량 콘크리트에 대한 221개의 데이터를 이용하여 콘크리트의 인장강도 (직접인장강도, 쪼갬인장강도 및 파괴계수)에 대한 설계기준과 기존 연구자들의 제안모델의 안정성을 평가하였다. 콘크리트 인장강도 예측을 위한 대부분의 제안 식들은 보통중량 콘크리트의 실험결과를 이용하여 압축강도의 함수로서 제시되었다. 하지만 데이터베이스의 분석은 콘크리트 인장강도는 기건 단위질량에 의해서도 중요한 영향을 받음을 보여준다. 이에 따라, 콘크리트 인장강도에 대한 기준 및 제안모델들은 기건 단위질량 2,100 kg/m3 이하, 압축강도 50 MPa 이상에서는 실험결과와의 불일치가 증가하였다. 한편, 본 연구에서 콘크리트 기건 단위질량을 고려하여 제시된 콘크리트 인장강도 예측 모델들은 실험결과와 비교적 잘 일치하였다.
와이어로프와 T형 강판을 이용한 비부착공법의 내진성능을 평가하기 위해 중심 축하중과 반복 횡하중을 받는 5개의 보강된 기둥과 무보강 기둥을 실험하였다. 주요 변수는 T형 강판의 정착방법과 피복 모르터의 유․무이다. 실험결과 T형 강판이 정착된 기둥의 하중분배로 인한 휨 내력 및 연성 증가를 확인할 수 있었다. 그러나 T형 강판이 정착되지 않은 기둥은 연성 증가에는 효과적이지만 T형 강판으로 하중이 분배되지 않았다. 피복 모르터가 있는 보강된 기둥은 효과적인 초기 강성 및 휨 내력 증가를 보였지만 연성증가에는 불리하였다. 단면분할법을 이용해 예측한 보강된 기둥의 최대 휨 내력은 등가응력블럭을 사용하여 예측한 ACI 318-05 기준보다 실험결과를 예측하였다.