검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study analyzed performance assessment factors of VOCs odor sensors from 3 different manufacturers, such as minimum detection limit, humidity stability and temperature stability. Through the minimum detection limit assessment, it was found that a VOCs sensor was able to detect TVOCs at the concentration of 5 ppb. The standard deviation ratio was over 10%, and it increased as humidity rose. The range of temperatures in which the VOCs odor sensor using photoionization could operate was between 25oC and 40oC, and the sensor output values were unstable at low temperatures. In terms of the temperature stability of the metal oxide semiconductor sensor for measuring complex odors, the sensor output values dropped considerably to 0~10oC, and were similar to the concentrations of odorous gases generated at 25oC. The results of the test of VOCs odor sensor outputs after temperature and humidity pre-treatment revealed that the respective stable output values at 50% humidity and 25oC were similar to the concentrations of manufactured odors. In terms of temperature and humidity stability of the VOCs odor sensors, all target VOCs substances had stable output values at 25oC to 40oC and at 50% to 65% relative humidities, and unstable values at low temperatures and high humidities. Therefore, the implementation of pre-treatment systems including temperature and humidity correction (25~40oC, 50~65% RH) is required for the stable use of VOCs odor sensors.
        4,000원