검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        2.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Underground cavities are frequently taking place in urban areas due to soil loss caused by structural defects of underground buried pipes. In this study, a field experimental program was conducted to detect ground condition using the electrical resistivity survey and the pneumatic cone penetration test. In addition, we proposed a method to estimate the weighted mean resistivity value by quantifying the electrical resistivity measurements through image analysis in order to compare the results of pneumatic cone penetration test. Consequently, it was found that as the weighted average resistivity value decreased, the smaller the N-value (penetration depth per blow number) from the pneumatic cone penetration test results. Based on the limited number of field experimental measurements, the correlation between weighted average resistivity value and the N-value of pneumatic cone penetration test is deemed promising in assessment of ground conditions associated with developing underground cavitation.
        4,000원
        3.
        2017.04 구독 인증기관 무료, 개인회원 유료
        최근 도심지에서 지중매설관의 구조적 결함에 의한 토사 유실로 인해 지하 공동이 빈번하게 발생하고 있다. 본 연구에서는 이러한 지하 공동을 파악하는데 있어 현장 실험 수행 결과 전기비저항 탐사와 공압콘관입시험이 지반 조건의 이상 징후를 탐지하는데 효율적임을 확인하였다. 또한, 이미지 분석을 통한 전기비저항 실험 측정값을 정량화 하여 평균 비저항 값을 산정하는 방법을 제안하였다. 실대형 실험 결과, 평균 비저항 값이 감소할수록 위험도가 증가하였고, 공압콘관입시험 결과, N치가 작을수록 위험도가 높다는 것을 확인하였으며, 제한적인 측정 데이터 수를 토대로 평균 비저항 값과 공압콘관입시험의 결과를 토대로 상관관계를 나타내었을 때, 지반의 지하공동 발생과 관련된 위험 수준을 제한적으로 평가할 수 있을 것으로 판단된다.
        3,000원
        4.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.
        4,000원