강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.
Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.
In this study, nonlinear finite element analysis based on the Modified Compression Field Theory has been conducted to evaluate shear strength of RC walls with opening. On the analysis, reinforcement ratio within development length of rebars nearby the opening was reduced in the model in order to investigate the effect of opening on shear strength of RC shear walls. The nonlinear finite element analysis has been verified through comparison with the test result in literature. Through the verification, it was investigated that the analysis considering the development length of rebars well reflected the effect of an opening on shear strength of RC shear walls while current design provisions did not reasonably consider one.
최근에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만, 내진설계 도입 이전의 건축물은 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 저층 RC구조물의 지진 발생 시 안전성 확보를 위한 내진보강 방안으로 격자강판 전단벽을 제안하고 내진성능평가를 수행하였다. 횡력저항요소로 사용된 격자강판 전단벽의 탄소성 이력특성값은 실험결과를 토대로 횡력저항 기여도등을 평가하여 작성된 이선형곡선을 적용하였다. 비탄성 정적해석을 통해 대상구조물의 성능점을 찾아내어 적용 지진하중에 대한 응답과 성능수준을 평가하였다. 격자강판 전단벽을 적용한 경우, 보강 전에 비하여 응답변위가 약 42% 저감되는 것을 확인할 수 있었으며, 성능점에서 거의 탄성거동을 보여주고 있어 목표성능인 인명안전수준을 만족시켰다. 또한 반응수정계수를 산정하여 내진보강 효과를 검증하였으며, 보강 전과 후에 각각 2.17에서 3.25로 증가하여 설계기준을 초과하였다. 따라서 격자강판 전단벽에 의해 대상 구조물의 강도 및 강성보강이 적절히 수행된 것으로 판단된다.
경계요소를 가지는 철근콘크리트 전단벽의 비선형 해석을 위한 간편 모델을 제안하였다. 이 간편 모델은 전단벽의 휨 및 전단 거동을 스프링요소로 나타낸 거시적 모델이다. 휨거동은 벽체의 단면해석을 기초로 한 모멘트강도와 회전능력을 벽체 양단의 수직 스프링요소로 나타내었다. 경계요소를 가지는 전단벽은 휨거동에 의해 지배되므로 전단거동은 휨거동에 바탕하여 변수를 계산하였고 중앙부 수평 스프링요소로 나타내었다. 제안된 모델은 전단벽 정적이력시험 결과와 비교한 후 비선형동적해석을 수행하여 사용된 이력법칙 및 변수들의 타당성을 조사하였다. 비선형동적해석을 이용한 변수연구를 통하여 내진성능평가의 주요변수인 요구값과 성능값에 미치는 영향을 검토하였다. 그 결과 전단력-전단변형 관계에서 약간의 차이가 있지만 전단벽의 전체거동은 잘 일치하였으며, 주요 변수의 변화에 대해 요구값과 성능값도 일정하게 변화하므로 제안된 해석모델은 경계요소를 가진 철근콘크리트 전단벽에 알맞은 것으로 판단된다.
본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.
본 연구의 목적은 초고층건물의 콘크리트 전단벽 아웃리거 두께를 산정하는 방법을 찾는 것이다. 이를 위해서 먼저 60층 규모의 초고층건물 해석모델을 생성하고 구조해석을 수행하였다. 다음에는 해석결과를 이용하여 아웃리거로 인한 하중 전달방식과 변형 양상의 변화를 고찰하고 이를 바탕으로 아웃리거 두께 산정식을 제안하였다. 마지막으로 해석모델을 다양하게 변화시켜 제안식의 타당성을 검토하였다.
In this study, an experimental study to investigate the shear friction behavior of the SC Wall to RC slab connection was carried out. The maximum shear friction capacity and failure mode were examined, and the results were also compared with theoretical value. Finally, the results are to be used for the basic reference of the design guideline(draft) for the RC-SC connection.
The purpose of this study is to present the new effective stiffness of special RC shear walls with flanges. ACI 318-99 adapt the different design provisions of effective stiffness between simple walls and walls with flanges. But domestic code makes no distinction between simple and with flanges walls. By the nonlinear analysis, maximum loads and displacement are calculated. Therefore the moment-curvature curve is calcultaed by the P-Δ curve. The stiffness ratios of cracked and uncracked section are calculated by the moment-curvature curves. And the stiffness ratios of simple walls and wall with flange are compared.
실무 및 연구에 있어서 반복하중을 받는 콘크리트 벽체의 변형 및 저항능력 그리고 재료의 변형율 등을 정확하게 평가할 수 있는 방법이 필요하다. 따라서 본 논문에서는 비선형 트러스 부재를 이용하여 반복 횡하중을 받는 철근콘크리트 벽체 또는 철근콘크리트 면부재를 모델링하였다. 콘크리트와 배근된 철근은 각각 수직, 수평 그리고 대각선 비선형 부재를 이용해 모델링되었다. 본 논문에서는 높이/폭 비가 1.2인 벽체를 예제로 선택하여 실험의 결과와 비교하였다. 비교를 위하여 주대각선 부재의 경로에 따른 4가지의 형상과 대각선 부재들의 배열에 따른 3가지 형상이 채택되어 실험 결과와 가장 근사한 모델링의 선택을 위해 평가를 실시하였다.