        2.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to evaluate the chemical quenching system for residual ozone and to determine the operating condition for the quenching system. Hydrogen peroxide (H₂O₂) and sodium thiosulfate (Na₂S₂O₃) were investigated as quenching reagents for ozone removal, and the tendency of each chemical was notably different. In the case of H₂O₂, the degradation rate of ozone was increased as the concentration of H₂O₂ increase, and temperature and pH value have a significant effect on the degradation rate of ozone. On the other hand, the degradation rate of ozone was not affected by the concentration of Na₂S₂O₃, temperature and pH value, due to the high reactivity between the S₂O₃²- and ozone. This study evaluates the decomposition mechanism of ozone by H₂O₂ and Na₂S₂O₃ with consideration for the water quality and reaction time. Furthermore, the removal test for the quenching reagents, which can be remained after reaction with ozone, was conducted by GAC process.
        4,200원