검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        2.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper analyzed structural behaviors of the staggered truss system, typically used in low seismicity regions, resisting the lateral loads such as wind and seismic load. A comparative study of cost and efficiency was carried out by analysing and designing the 10- and 20-story buildings with various types of truss, including pratt, howe, warren, K-, and vierendeel, which may typically be used in staggered truss system. In design, column and truss members are selected in group, and the efficiency of the member design was judged by average demand capacity ratio of the all members in same group. And economic analysis of the system was investigated by the quantity of the structural members. As a result, staggered truss system with the pratt truss and warren truss showed the most economical and efficient performance for 10-story building, and 20-story building, respectively.
        4,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The new rotary friction damper was developed using several two-nodal rotary frictional components with different clamping forces. Because of these components, the rotary friction damper can be activated by building movements due to lateral forces such as a wind and earthquake. In this paper, various dependency tests such as displacement amplitude, forcing frequency and long term cyclic loading were carried out to evaluate on the structural performance and the multi-slip mechanism of the new damper. Test results show that the multi-slip mechanism is verified and friction coefficients are dependent on displacement amplitute and forcing frequency except long term cyclic loading.
        4,000원
        4.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents on the structural behavior of the the methyl methacrylate monomer (MMA) double wide flanged the glass fiber-reinforced polymer(GFRP) pipe composite structures for the manhole raise. The evaluation of structural performance on this composite structure was conducted by the axial load, fatigue load, and ultimate load test. The assessment indicates that the MMA double wide flanged GFRP pipe composite structures was confirmed safety, durability and reliability in result as expected. It was found that this composite structure was able to short working times to around 30-50% and construction costs to around 10-23% with compare other construction methods. Also, environmental pollution and civil complaints will be prevented because there will be no longer any noises, vibrations, dust, or construction wastes.
        4,300원