검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated and analyzed the registration, sales and regulatory management system of in vitro diagnostic veterinary medical reagents (IVDVMRs) in Korea. The registration of IVDVMRs has gradually increased since 2000, and total of 233 products from 58 companies were registered from 1975 to 2014. The market size of IVDVMRs is estimated to be approximately 12 billion Won per year from 2011 to 2013: the export sales and proportion was estimated to be 36.8% as 4.4 billion Won in 2013. Of these products, the ranking of the sales were canine heartworm, bovine tuberculosis, swine fever, porcine reproductive and respiratory syndrome, canine distemper+adenovirus+parvovirus disease, foot and mouth disease, etc. In vitro diagnostic human medical reagents were diverted biological medicine from the medical devices by the revision of the Pharmaceutical Affairs Law Enforcement Regulations in 2014 in Korea. In contrast, in vitro diagnostic devices for animal were still managed as medical devices and biological medicines, respectively. The diagnostic reagents for infectious diseases have neither classification nor grade systems. Good manufacturing practices (GMP) requirements on IVDVMRs were also exempted from the current system. This study suggested that the registration of the IVDVMRs has increased since 2005, and regulations of these devices should be improved for the effective operating system.
        4,000원
        2.
        2011.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        If the purpose of an assessment is diagnosing examinees’ knowledge states to improve their learning, more fine-grained information than the overall level of their ability is necessary. Recent advances in diagnostic assessment triggered the development of cognitive diagnosis models (CDMs), such as the deterministic inputs, noisy “And” gate (DINA) model. Although CDMs for language assessments have been applied to reading or listening test data, a CDM may produce more practical results if the construct to measure has specific and well-defined skill attributes as in a grammar assessment. For this study, a grammar test consisting of 40 multiple-choice items was administered to 3,000 Korean learners of English as a foreign language. From the test items, a Q-matrix, which is an essential tool for CDMs, was constructed based on six grammar skills. As a result, skill profiles were obtained for all examinees. This diagnostic information can be used for tailored instruction. Issues with regard to applications of CDMs to language assessments are also discussed.
        4,200원
        4.
        2018.12 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 국가에서 권고하고 있는 일발촬영 진단참고준위 설정에 사용된 조건을 조사하여 PCXMC v2.0 프로그램을 이용하여 유효선량을 측정하고 생물학적 평가를 해보고자 한다. 그 결과 ICRP 60에서 유효선량은 가장 높은 Pelvis AP는 0.794 mSv 가장 낮은 Chest PA는 0.050 mSv이었다. ICRP 103에서는 남성이 가장 높은 T-Spine AP는 0.733 mSv 가장 낮은 Chest PA는 0.057 mSv, 여성은 가장 높은 T-Spine AP는 0.906 mSv 가장 낮은 Chest PA는 0.052 mSv이었다. 남녀 성인 40세 기준으로 일반 촬영별 유효선량을 평가 해 보았고, 선량한도의 제한을 받지 않는 의료피폭이라도 방사선위해의 확률적 영향을 최소화하기 위해서 선량을 권고량 이하로 유지하여 국민의 의료피폭을 줄이기 위해 노력이 필요할 것으로 사료된다.
        5.
        2017.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 몬테카를로 전산해석법으로 K대학교 진료영상 촬영 실습실의 방사선 조사실과 발생장치 제어실 내부 공간 유효선량률 분포 계산을 수행하였다. 방사선 발생장치는 최대 관전압 150 kVp에 최대 관 전류 700 mA이다. 전산해석 결과를 이용하여 차폐문이 닫힌 경우와 열린 경우의 진료영상 촬영 실습실의 공간선량 분포를 비교 평가하였다. 결과적으로, 차폐문이 열린 경우에도 방사선 발생장치 제어실의 유효선 량률은 학생(수시출입자)의 연간 유효선량률 한도(6 mSv/y)를 초과하지 않는다는 것을 알 수 있었다. 하지 만, 차폐문이 열려있을 때의 유효선량률이 차폐문이 닫힌 경우에 비해 납유리 앞에서는 약 16배, 차폐문 앞 에서는 약 3,000배 더 높기 때문에 실습 중에 차폐문을 닫는 것이 불필요한 방사선 피폭을 크게 줄인다는 것을 알 수 있었다.
        6.
        2012.08 KCI 등재 서비스 종료(열람 제한)
        16MD CT(n=93) and dual source CT(n=100)를 이용해 촬영된 심장 CT 중 그 결과 협착으로 진단되어 심장영화 촬영을 시행한 환자를 대상으로 심장영화 촬영과의 협착 유무에 대한 비교를 하였다. 그 결과 16MDCT의 경우 가장 높은 민감도, 특이도, 양성예측도, 음성예측도는 LAD(73.5%), RCA(74.5%), LAD(66.7%), LCX(75%),LCX(67.7%)로 나타났고, 16Slice MDCT에서 각 관상동맥 혈관별 정확도는 평균67%로 다소 떨어지는 것으로 나타났고, Somatom Definition dual source CT의 경우 평균 정확도 84%로 16Slice MDCT보다는 17%더 높은 정확도를나타내었다. 관상동맥영역별(segaments) 구분에서는 16Slice MDCT와 Somatom Definition 모두 근위부(proximal)보다는 원위부로 갈수록 더 높은 정확도를 나타내었다. 하지만 그 결과 값이 10% 오차 범위 내에 있어 명확한 차이라보기는 힘들 것 이다. 또한 Dual source CT의 경우 역시 관상동맥 영역별 구분에서 큰 차이를 보이지 않았다.