검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Abstract Purpose : The purpose of this study is to evaluate the differences and reliability of various methods for measuring Interpupillary Distance. Methods : The participants were 50 Cambodian adults (28.08±3.85 years old) without ocular disease and abnormal binocular vision. Far/near IPD was measured using Corneal reflection pupillometer, PD ruller and spotting, and calculated formula for fixation distance. Using each method, the pupil distance of both eyes was measured three times, respectively, and the average value was recorded. Results : The average value of the corneal reflection pupilometer in the distance was 63.08±3.42 mm, the average value of PD calculated formula was 62.97±3.41 mm, the average value of the PD ruler was 63.72±3.17 mm, and the average value of the spotting method was 63.89±3.15 mm. The average value of the corneal reflection pupilometer in the near was 59.85±3.23 mm, the average value of the calculated formula for fixation distance was 59.95±3.23 mm, the average value of PD ruler was 59.72±3.29 mm, and the average value spotting method was 59.47±3.23 mm. Comparison between various methods in the distance and near showed statistically significant differences (p<0.001). Conclusion : In the comparative analysis between each method, the corneal reflection pupillometer is considered to be the most accurate method, but since there is no significant difference from the average value of the Spotting method, the PD Ruler Viktorin method, and the calculated formula for fixation distance, whichever method is used, it is clinically acceptable. Therefore it is believed that each method is compatible with each other. Key words : Corneal reflection pupillometer, PD meter, PD ruler, Spotting
        4,000원
        4.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.
        4,000원
        5.
        2004.06 KCI 등재 서비스 종료(열람 제한)
        This paper introduces a novel approach that can provide the three dimensional information about the movement of a spreader by using two CCD cameras and a laser distance measuring unit in order to derive ALS (Automatic Landing System) in the crane used at a harbor. So far a kind of 2D Laser scanner sensor or laser distance measuring units are used as comer detectors for the geometrical matching between the spreader and a container. Such systems provide only two dimensional information which is not enough for an accurate and fast ALS. In addition to this deficiency in performance, the price of the system is too high to adapt to the ALS. Therefore, to overcome these defects, we proposed a novel method to acquire the three dimensional spreader information using two CCD cameras and a laser distance measuring unit. To show the efficiency of proposed method, real experiments are performed to show the improvement of accuracy in distance measurement by fusing the sensory information of the CCD cameras and a laser distance measuring unit.